Publication: Evaluation of the total hydrodynamic energy loss using 4D flow MRI in a case with Fontan failure
dc.contributor.coauthor | Aka, İbrahim Başar | |
dc.contributor.department | Department of Mechanical Engineering | |
dc.contributor.kuauthor | Ödemiş, Ender | |
dc.contributor.kuauthor | Gümüş, Terman | |
dc.contributor.kuauthor | Özkök, Serçin | |
dc.contributor.kuauthor | Pekkan, Kerem | |
dc.contributor.other | Department of Mechanical Engineering | |
dc.contributor.schoolcollegeinstitute | School of Medicine | |
dc.contributor.schoolcollegeinstitute | Graduate School of Sciences and Engineering | |
dc.contributor.schoolcollegeinstitute | College of Engineering | |
dc.contributor.unit | Koç University Hospital | |
dc.date.accessioned | 2024-12-29T09:37:38Z | |
dc.date.issued | 2024 | |
dc.description.abstract | Fontan Failure (FF) is a common problem for single-ventricle patients as they reach adulthood. Although several mechanisms may cause FF, an optimized blood flow stream through the surgical conduits is essential to avoid excessive energy loss (EL). Recent clinical studies showed EL is related to the quality of life, exercise capacity, and hepatic function since the single-ventricle feeds pulmonary and systemic circulation serially. 4D flow MRI effectively estimates EL in Fontan circulation and allows clinicians to compare the effectiveness of the treatment strategy concerning pre-intervention. Here, we present 26-year-old women with FF who had normal cardiac catheterization findings and were treated according to high EL definitions that are measured through 4D flow MRI. © 2024 | |
dc.description.indexedby | WoS | |
dc.description.indexedby | Scopus | |
dc.description.indexedby | PubMed | |
dc.description.issue | 6 | |
dc.description.openaccess | All Open Access | |
dc.description.openaccess | Gold Open Access | |
dc.description.publisherscope | International | |
dc.description.sponsoredbyTubitakEu | TÜBİTAK | |
dc.description.sponsors | We acknowledge TUBITAK 2247A lead researcher award 120C139 and ERC ( European Research Council ) Proof of Concept 969765 BloodTurbine providing funding. The Circle CVI company did not respond to the Author's inquiry requesting the details of their hydrodynamic dissipation calculation. | |
dc.description.volume | 10 | |
dc.identifier.doi | 10.1016/j.heliyon.2024.e28140 | |
dc.identifier.eissn | 2405-8440 | |
dc.identifier.quartile | Q1 | |
dc.identifier.scopus | 2-s2.0-85187991826 | |
dc.identifier.uri | https://doi.org/10.1016/j.heliyon.2024.e28140 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14288/22429 | |
dc.identifier.wos | 1208440000001 | |
dc.keywords | 4D flow MRI | |
dc.keywords | Cardiac MRI | |
dc.keywords | Energy dissipation | |
dc.keywords | Fontan | |
dc.keywords | Hemodynamics | |
dc.language | en | |
dc.publisher | Elsevier | |
dc.relation.grantno | European Research Council, ERC | |
dc.relation.grantno | Türkiye Bilimsel ve Teknolojik Araştırma Kurumu, TÜBİTAK, (2247A, 120C139) | |
dc.source | Heliyon | |
dc.subject | Fontan procedure | |
dc.subject | Congenital heart defect | |
dc.subject | Pediatrics | |
dc.title | Evaluation of the total hydrodynamic energy loss using 4D flow MRI in a case with Fontan failure | |
dc.type | Journal article | |
dspace.entity.type | Publication | |
local.contributor.kuauthor | Ödemiş, Ender | |
local.contributor.kuauthor | Gümüş, Terman | |
local.contributor.kuauthor | Özkök, Serçin | |
local.contributor.kuauthor | Pekkan, Kerem | |
relation.isOrgUnitOfPublication | ba2836f3-206d-4724-918c-f598f0086a36 | |
relation.isOrgUnitOfPublication.latestForDiscovery | ba2836f3-206d-4724-918c-f598f0086a36 |