Publication:
Evaluation of the total hydrodynamic energy loss using 4D flow MRI in a case with Fontan failure

dc.contributor.coauthorAka, İbrahim Başar
dc.contributor.departmentDepartment of Mechanical Engineering
dc.contributor.kuauthorÖdemiş, Ender
dc.contributor.kuauthorGümüş, Terman
dc.contributor.kuauthorÖzkök, Serçin
dc.contributor.kuauthorPekkan, Kerem
dc.contributor.otherDepartment of Mechanical Engineering
dc.contributor.schoolcollegeinstituteSchool of Medicine
dc.contributor.schoolcollegeinstituteGraduate School of Sciences and Engineering
dc.contributor.schoolcollegeinstituteCollege of Engineering
dc.contributor.unitKoç University Hospital
dc.date.accessioned2024-12-29T09:37:38Z
dc.date.issued2024
dc.description.abstractFontan Failure (FF) is a common problem for single-ventricle patients as they reach adulthood. Although several mechanisms may cause FF, an optimized blood flow stream through the surgical conduits is essential to avoid excessive energy loss (EL). Recent clinical studies showed EL is related to the quality of life, exercise capacity, and hepatic function since the single-ventricle feeds pulmonary and systemic circulation serially. 4D flow MRI effectively estimates EL in Fontan circulation and allows clinicians to compare the effectiveness of the treatment strategy concerning pre-intervention. Here, we present 26-year-old women with FF who had normal cardiac catheterization findings and were treated according to high EL definitions that are measured through 4D flow MRI. © 2024
dc.description.indexedbyWoS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.issue6
dc.description.openaccessAll Open Access
dc.description.openaccessGold Open Access
dc.description.publisherscopeInternational
dc.description.sponsoredbyTubitakEuTÜBİTAK
dc.description.sponsorsWe acknowledge TUBITAK 2247A lead researcher award 120C139 and ERC ( European Research Council ) Proof of Concept 969765 BloodTurbine providing funding. The Circle CVI company did not respond to the Author's inquiry requesting the details of their hydrodynamic dissipation calculation.
dc.description.volume10
dc.identifier.doi10.1016/j.heliyon.2024.e28140
dc.identifier.eissn2405-8440
dc.identifier.quartileQ1
dc.identifier.scopus2-s2.0-85187991826
dc.identifier.urihttps://doi.org/10.1016/j.heliyon.2024.e28140
dc.identifier.urihttps://hdl.handle.net/20.500.14288/22429
dc.identifier.wos1208440000001
dc.keywords4D flow MRI
dc.keywordsCardiac MRI
dc.keywordsEnergy dissipation
dc.keywordsFontan
dc.keywordsHemodynamics
dc.languageen
dc.publisherElsevier
dc.relation.grantnoEuropean Research Council, ERC
dc.relation.grantnoTürkiye Bilimsel ve Teknolojik Araştırma Kurumu, TÜBİTAK, (2247A, 120C139)
dc.sourceHeliyon
dc.subjectFontan procedure
dc.subjectCongenital heart defect
dc.subjectPediatrics
dc.titleEvaluation of the total hydrodynamic energy loss using 4D flow MRI in a case with Fontan failure
dc.typeJournal article
dspace.entity.typePublication
local.contributor.kuauthorÖdemiş, Ender
local.contributor.kuauthorGümüş, Terman
local.contributor.kuauthorÖzkök, Serçin
local.contributor.kuauthorPekkan, Kerem
relation.isOrgUnitOfPublicationba2836f3-206d-4724-918c-f598f0086a36
relation.isOrgUnitOfPublication.latestForDiscoveryba2836f3-206d-4724-918c-f598f0086a36

Files