Publication:
Design and optimization of microlens array based high resolution beam steering system

dc.contributor.departmentN/A
dc.contributor.departmentDepartment of Electrical and Electronics Engineering
dc.contributor.departmentDepartment of Electrical and Electronics Engineering
dc.contributor.kuauthorAkatay, Ata
dc.contributor.kuauthorÜrey, Hakan
dc.contributor.kuprofileMaster Student
dc.contributor.kuprofileFaculty Member
dc.contributor.schoolcollegeinstituteGraduate School of Sciences and Engineering
dc.contributor.schoolcollegeinstituteCollege of Engineering
dc.contributor.yokidN/A
dc.contributor.yokid8579
dc.date.accessioned2024-11-10T00:01:47Z
dc.date.issued2007
dc.description.abstractHigh-resolution imaging and beam steering using 3 microlens arrays (MLA) is demonstrated. Small lateral displacement of one microlens array is sufficient for large angle beam steering. A prescan lens is added to the system to overcome the discrete addressing problem associated with microlens scanning systems. A hybrid method that uses both geometrical ray tracing optimization and physical optics simulation is introduced for the design and optimization of the MLA system. Feasibility of 1880 x 1880 resolution using f/2 aspherical MLAs and 752 x 752 resolution using f/5 spherical MLAs are demonstrated assuming 100 mu m microlens pitch and 2mm clear aperture. The system is compact and suitable for endoscopic imaging and agile steering of large beams. (c) 2007 Optical Society of America.
dc.description.indexedbyWoS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.issue8
dc.description.openaccessYES
dc.description.publisherscopeInternational
dc.description.sponsoredbyTubitakEuTÜBİTAK
dc.description.sponsorshipThis research is partly sponsored by EC-FP6 program NEMO network, TÜBİTAK grant 106E068, and TÜBİTAK Graduate Scholarship Program.
dc.description.volume15
dc.identifier.doi10.1364/OE.15.004523
dc.identifier.issn1094-4087
dc.identifier.quartileQ1
dc.identifier.scopus2-s2.0-34247240557
dc.identifier.urihttp://dx.doi.org/10.1364/OE.15.004523
dc.identifier.urihttps://hdl.handle.net/20.500.14288/16035
dc.identifier.wos245782500013
dc.languageEnglish
dc.publisherOptical Soc Amer
dc.sourceOptics Express
dc.subjectOptics
dc.titleDesign and optimization of microlens array based high resolution beam steering system
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.authorid0000-0003-0463-2171
local.contributor.authorid0000-0002-2031-7967
local.contributor.kuauthorAkatay, Ata
local.contributor.kuauthorÜrey, Hakan
relation.isOrgUnitOfPublication21598063-a7c5-420d-91ba-0cc9b2db0ea0
relation.isOrgUnitOfPublication.latestForDiscovery21598063-a7c5-420d-91ba-0cc9b2db0ea0

Files