Publication:
Magnetic probe-guided excision of nonpalpable neck lesions: a new and safe technique for operated neck compartments

dc.contributor.coauthorAksakal, Nihat
dc.contributor.coauthorOzturk, Alper
dc.contributor.coauthorTutal, Firat
dc.contributor.coauthorDogan, Selim
dc.contributor.coauthorBulakci, Mesut
dc.contributor.coauthorBarbaros, Umut
dc.contributor.coauthorErbil, Yesim
dc.contributor.kuauthorAğcaoğlu, Orhan
dc.contributor.kuprofileFaculty Member
dc.contributor.schoolcollegeinstituteSchool of Medicine
dc.contributor.yokid175476
dc.date.accessioned2024-11-09T23:19:32Z
dc.date.issued2017
dc.description.abstractBackground: Reoperative neck surgery is technically more demanding because of the presence of scar tissue and distorted anatomy. We aimed to investigate the magnetic probe-guided excision of nonpalpable neck lesions in patients with previously operated neck compartments. Methods: This study included 9 patients with recurrent/persistent thyroid carcinoma, recurrent/persistent hyperparathyroidism with previously operated neck compartments. The pathologic lesions were localized by ultrasonography, and magnetic tracer (0.2 mL, iron oxide) was injected directly into the pathologic lesions. Careful dissection was carried out following the area of maximum magnetic activity until the nonpalpable lesions were identified and excised. Result: All neck lesions were removed in 9 patients. The median count from lesion was significantly higher than values from lesion bed (background activity; (9900/5 seconds vs 250/5 seconds, P < .001). During follow-up, all patients had negative ultrasonography. Conclusion: Magnetic probe-guided technique could provide access to nonpalpable lesion localization in centers without readily available access to nuclear medicine facilities.
dc.description.indexedbyWoS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.issue1
dc.description.openaccessNO
dc.description.publisherscopeInternational
dc.description.volume24
dc.identifier.doi10.1177/1553350616676444
dc.identifier.eissn1553-3514
dc.identifier.issn1553-3506
dc.identifier.quartileQ3
dc.identifier.scopus2-s2.0-85011304336
dc.identifier.urihttp://dx.doi.org/10.1177/1553350616676444
dc.identifier.urihttps://hdl.handle.net/20.500.14288/10566
dc.identifier.wos394903900006
dc.keywordsPapillary thyroid cancer
dc.keywordsMetastatic lymph nodes
dc.keywordsReoperation
dc.keywordsMagnetic probe-guided excision
dc.keywordsRecurrent thyroid-cancer
dc.keywordsLocalization
dc.keywordsNode
dc.languageEnglish
dc.publisherSage
dc.sourceSurgical Innovation
dc.subjectSurgery
dc.titleMagnetic probe-guided excision of nonpalpable neck lesions: a new and safe technique for operated neck compartments
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.authorid0000-0003-1617-3953
local.contributor.kuauthorAğcaoğlu, Orhan

Files