Publication:
Development and psychometric evaluation of a medical device-related pressure ınjury risk assessment scale

dc.contributor.coauthorDalli, Ö. E.
dc.contributor.departmentGraduate School of Health Sciences
dc.contributor.departmentSchool of Nursing
dc.contributor.kuauthorUçanbelen, Aleyna
dc.contributor.kuauthorKaradağ, Ayişe
dc.contributor.schoolcollegeinstituteSCHOOL OF NURSING
dc.contributor.schoolcollegeinstituteGRADUATE SCHOOL OF HEALTH SCIENCES
dc.date.accessioned2026-07-07T08:48:59Z
dc.date.issued2026
dc.description.abstractMedical device–related pressure injuries are a significant and largely preventable patient safety problem, yet existing pressure injury risk scales do not adequately capture device‐specific risk factors in adults. This methodological study developed and psychometrically evaluated a standardized risk assessment scale to identify medical device–related pressure injury risk in hospitalized adult patients. An initial item pool was generated from an extensive literature review and clinical expertise, and content validity was assessed by seven experts using the Davis technique (content validity index = 0.96). The scale was administered to 160 adults receiving at least one medical device in medical, surgical and oncology wards and intensive care units of a university hospital. Construct validity was evaluated using binary logistic regression, exploratory factor analysis, and receiver operating characteristic curve analysis, demonstrating strong discrimination (area under the curve = 0.844, 95% confidence interval 0.728–0.961) with an optimal cut‐off score of 14.5 (sensitivity 70.6%, specificity 88.8%). Exploratory factor analysis of the final version of the MedRAS (Kaiser‐Meyer‐Olkin = 0.792) revealed a two‐factor structure (Device and Mechanical Factors; Patient and Tissue Factors) explaining 50.92% of the total variance, with all factor loadings above 0.30. The scale showed good internal consistency (Cronbach's alpha = 0.80) and very good inter‐rater reliability (Cohen's kappa = 0.806, p < 0.001). This device‐focused scale may support early risk identification and targeted preventive nursing interventions, with potential to improve patient safety and quality of care in inpatient/critical care settings.
dc.description.harvestedfromManual
dc.description.indexedbyWOS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.publisherscopeInternational
dc.description.readpublishN/A
dc.description.sponsoredbyTubitakEuN/A
dc.description.versionPublished Version
dc.identifier.WoSQuartileQ2
dc.identifier.doi10.1111/iwj.70918
dc.identifier.eissn1742-481X
dc.identifier.embargoN/A
dc.identifier.issn1742-4801
dc.identifier.issue4
dc.identifier.pubmed41991483
dc.identifier.scopus2-s2.0-105035819346
dc.identifier.urihttp://doi.org/10.1111/iwj.70918
dc.identifier.urihttps://hdl.handle.net/20.500.14288/33251
dc.identifier.volume23
dc.identifier.wos001742168300001
dc.keywordsMedical devices
dc.keywordsPressure ulcer
dc.keywordsPsychometrics
dc.keywordsRisk assessment
dc.keywordsScale development
dc.keywordsSensitivity and specificity
dc.languageeng
dc.publisherWiley
dc.relation.affiliationKoç University
dc.relation.collectionKoç University Institutional Repository
dc.relation.ispartofInternational Wound Journal
dc.relation.openaccessN/A
dc.rightsN/A
dc.rights.uriN/A
dc.subjectDermatology
dc.subjectSurgery
dc.titleDevelopment and psychometric evaluation of a medical device-related pressure ınjury risk assessment scale
dc.typeJournal Article
dspace.entity.typePublication
relation.isOrgUnitOfPublication2f870f28-12c9-4b28-9465-b91a69c1d48c
relation.isOrgUnitOfPublicationcd883b5a-a59a-463b-9038-a0962a6b0749
relation.isOrgUnitOfPublication.latestForDiscovery2f870f28-12c9-4b28-9465-b91a69c1d48c
relation.isParentOrgUnitOfPublication9781feb6-cb81-4c13-aeb3-97dae2048412
relation.isParentOrgUnitOfPublication4c75e0a5-ca7f-4443-bd78-1b473d4f6743
relation.isParentOrgUnitOfPublication.latestForDiscovery9781feb6-cb81-4c13-aeb3-97dae2048412

Files