Publication:
Preliminary simulation study of carotid artery and pharyngeal constrictor muscle sparing-radiotherapy in glottic carcinoma

dc.contributor.coauthorÖzdemir, Yurday
dc.contributor.coauthorAcıbucu, İbrahim
dc.contributor.coauthorTopkan, Erkan
dc.contributor.kuauthorSelek, Uğur
dc.contributor.kuprofileFaculty Member
dc.contributor.schoolcollegeinstituteSchool of Medicine
dc.contributor.yokid27211
dc.date.accessioned2024-11-09T13:18:57Z
dc.date.issued2020
dc.description.abstractBackground: this preliminary simulation study aimed to compare the dosimetric outcomes of carotid arteries (CAs) and pharyngeal constrictor muscle (PCM) in patients with T1N0M0 glottic carcinoma undergoing helical tomotherapy-intensity modulated radiotherapy (HT-IMRT) and 3-dimensional conformal radiotherapy (3D-CRT) plans. Methods: in addition to the clinical target volume (CTV) which was defined as the entire larynx, the CAs and PCM of 11 glottic carcinoma patients were delineated. The CTV was uniformly expanded 5 mm to create a planning target volume (PTV) relative to the PCM and at a distance of 2 mm from the CA. The dosimetric characteristics in HT-IMRT and lateral opposed fields-based 3D-CRT plans were analyzed. Results: median D(95%)and V(100%)of PTV were significantly higher in HT-IMRT (p < 0.001) compared to 3D-CRT. The right/left CA dosimetric outcomes, including the mean doses (20.7/21.5 Gy versus 48.7/50.5 Gy), D-max(53.6/52.0 Gy versus 67.4/67.7 Gy), V-30(25.0/27.1% versus 77.6/80.3%), V-40(8.0/7.9% versus 74.6/71.9%), and V-50(2.0/1.2% versus 70.0/71.6%) were also significantly lower in HT-IMRT (p < 0.05), similar to the mean PCM doses (49.6 Gy versus 62.6 Gy for 3D-CRT;p < 0.001), respectively. Conclusions: our present results demonstrated the feasibility of simultaneous sparing of the CAs and PCM in HT-IMRT- compared to 3D-CRT plans in glottic carcinoma patients undergoing definitive radiotherapy.
dc.description.fulltextYES
dc.description.indexedbyWoS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.openaccessYES
dc.description.publisherscopeInternational
dc.description.sponsoredbyTubitakEuN/A
dc.description.sponsorshipN/A
dc.description.versionPublisher version
dc.description.volume19
dc.formatpdf
dc.identifier.doi10.1177/1533033820956989
dc.identifier.eissn1533-0338
dc.identifier.embargoNO
dc.identifier.filenameinventorynoIR02492
dc.identifier.issn1533-0346
dc.identifier.linkhttps://doi.org/10.1177/1533033820956989
dc.identifier.quartileN/A
dc.identifier.scopus2-s2.0-85092682843
dc.identifier.urihttps://hdl.handle.net/20.500.14288/3063
dc.identifier.wos578510200001
dc.keywordsGlottic carcinoma
dc.keywordsPharyngeal constrictor muscle
dc.keywordsCarotid arteries
dc.keywordsHelical-tomotherapy
dc.keywords3D-conformal radiotherapy
dc.languageEnglish
dc.publisherSage
dc.relation.grantnoNA
dc.relation.urihttp://cdm21054.contentdm.oclc.org/cdm/ref/collection/IR/id/9130
dc.sourceTechnology in Cancer Research _ Treatment
dc.subjectMedicine
dc.subjectOncology
dc.titlePreliminary simulation study of carotid artery and pharyngeal constrictor muscle sparing-radiotherapy in glottic carcinoma
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.authorid0000-0001-8087-3140
local.contributor.kuauthorSelek, Uğur

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
9130.pdf
Size:
457.36 KB
Format:
Adobe Portable Document Format