Publication:
A DASH7-based power metering system

dc.contributor.kuauthorAkan, Özgür Barış
dc.contributor.kuauthorÇetinkaya, Oktay
dc.contributor.schoolcollegeinstituteCollege of Engineering
dc.date.accessioned2024-11-09T12:18:58Z
dc.date.issued2015
dc.description.abstractConsidering the inability of the existing energy resources to satisfy the current needs, the right and efficient. use of the energy has become compulsory. To make energy sustainability permanent, management and planning activities should be carried out by arranging the working hours and decreasing the energy wasting. For all these, power metering, managing and controlling systems or plugs has been proposed in recent efforts. Starting from this point, a new DASH7-based Smart Plug (D7SP) is designed and implemented to achieve a better structure compared to ZigBee equipped models and reduce the drawbacks of current applications. DASH7 technology reaches nearly 6 times farther distances in comparison with 2.4 GHz based protocols and provides multi-year battery life as a result of using limited energy during transmission. Performing in the 433 MHz band prevents the possible interference from overcrowded 2.4 GHz and the other frequencies which helps to gather a more reliable working environment. To shorten the single connection delays and human oriented failures, the MCU was shifted directly into the plug from the rear-end device. Working hours arrangement and standby power cutting off algorithms are implemented in addition to these energy saving targeted improvements to enhance more efficient systems. With the collaboration of the conducted hardware and software oriented adjustments and DASH7-based improvements, a more reliable, mobile and efficient system has been obtained in this work.
dc.description.fulltextYES
dc.description.indexedbyWOS
dc.description.indexedbyScopus
dc.description.openaccessYES
dc.description.publisherscopeInternational
dc.description.sponsoredbyTubitakEuN/A
dc.description.sponsorshipN/A
dc.description.versionAuthor's final manuscript
dc.identifier.doi10.1109/CCNC.2015.7158010
dc.identifier.embargoNO
dc.identifier.filenameinventorynoIR01106
dc.identifier.isbn978-1-4799-6390-4
dc.identifier.issn2331-9852
dc.identifier.quartileN/A
dc.identifier.scopus2-s2.0-84943171419
dc.identifier.urihttps://doi.org/10.1109/CCNC.2015.7158010
dc.identifier.wos380402400074
dc.keywordsZigbee
dc.keywordsProtocols
dc.keywordsWireless communication
dc.keywordsRelays
dc.keywordsPerformance evaluation
dc.keywordsReliability
dc.keywordsDelays
dc.language.isoeng
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)
dc.relation.ispartof2015 12th Annual IEEE
dc.relation.urihttp://cdm21054.contentdm.oclc.org/cdm/ref/collection/IR/id/1959
dc.subjectComputer science
dc.subjectEngineering
dc.subjectTelecommunications
dc.titleA DASH7-based power metering system
dc.typeConference Proceeding
dspace.entity.typePublication
local.contributor.kuauthorÇetinkaya, Oktay
local.contributor.kuauthorAkan, Özgür Barış
local.publication.orgunit1College of Engineering
relation.isParentOrgUnitOfPublication8e756b23-2d4a-4ce8-b1b3-62c794a8c164
relation.isParentOrgUnitOfPublication.latestForDiscovery8e756b23-2d4a-4ce8-b1b3-62c794a8c164

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
1959.pdf
Size:
5.8 MB
Format:
Adobe Portable Document Format