Publication:
Perception of delay in computer input devices establishing a baseline for signal processing of motion sensor systems

dc.contributor.coauthorDu, Jiaying
dc.contributor.coauthorKade, Daniel
dc.contributor.coauthorGerdtman, Christer
dc.contributor.coauthorLindell, Rikard
dc.contributor.coauthorLinden, Maria
dc.contributor.departmentDepartment of Media and Visual Arts
dc.contributor.kuauthorÖzcan, Oğuzhan
dc.contributor.kuprofileFaculty Member
dc.contributor.otherDepartment of Media and Visual Arts
dc.contributor.researchcenterResearch Center for Creative Industries (KUAR) / KU Arçelik Yaratıcı Endüstriler Uygulama ve Araştırma Merkezi (KUAR)
dc.contributor.schoolcollegeinstituteCollege of Social Sciences and Humanities
dc.contributor.yokid12532
dc.date.accessioned2024-11-09T23:59:16Z
dc.date.issued2016
dc.description.abstractNew computer input devices in healthcare applications using small embedded sensors need firmware filters to run smoothly and to provide a better user experience. Therefore, it has to be investigated how much delay can be tolerated for signal processing before the users perceive a delay when using a computer input device. This paper is aimed to find out a threshold of unperceived delay by performing user tests with 25 participants. A communication retarder was used to create delays from 0 to 100 ms between a receiving computer and three different USB-connected computer input devices. A wired mouse, a wifi mouse and a head-mounted mouse were used as input devices. The results of the user tests show that delays up to 50 ms could be tolerated and are not perceived as delay, or depending on the used device still perceived as acceptable.
dc.description.indexedbyWoS
dc.description.indexedbyScopus
dc.description.openaccessNO
dc.description.volume187
dc.identifier.doi10.1007/978-3-319-51234-1_17
dc.identifier.isbn978-3-319-51234-1
dc.identifier.isbn978-3-319-51233-4
dc.identifier.issn1867-8211
dc.identifier.scopus2-s2.0-85011301202
dc.identifier.urihttp://dx.doi.org/10.1007/978-3-319-51234-1_17
dc.identifier.urihttps://hdl.handle.net/20.500.14288/15605
dc.identifier.wos428954100017
dc.keywordsComputer mouse
dc.keywordsDelay
dc.keywordsEmbedded systems
dc.keywordsHealthcare
dc.keywordsPerception
dc.keywordsUSB
dc.languageEnglish
dc.publisherSpringer International Publishing Ag
dc.sourceInternet Of Things Technologies For Healthcare, Healthyiot 2016
dc.subjectComputer science
dc.subjectHealth care sciences and services
dc.subjectTelecommunications
dc.titlePerception of delay in computer input devices establishing a baseline for signal processing of motion sensor systems
dc.typeConference proceeding
dspace.entity.typePublication
local.contributor.authorid0000-0002-4410-3955
local.contributor.kuauthorÖzcan, Oğuzhan
relation.isOrgUnitOfPublication483fa792-2b89-4020-9073-eb4f497ee3fd
relation.isOrgUnitOfPublication.latestForDiscovery483fa792-2b89-4020-9073-eb4f497ee3fd

Files