Publication:
Reliability of sonographic muscle thickness measurements of the thenar and hypothenar muscles

dc.contributor.coauthorN/A
dc.contributor.departmentN/A
dc.contributor.kuauthorMısırlıoğlu, Tuğçe Özekli
dc.contributor.kuauthorTaşkıran, Özden Özyemişçi
dc.contributor.kuprofileDoctor
dc.contributor.kuprofileFaculty Member
dc.contributor.schoolcollegeinstituteN/A
dc.contributor.schoolcollegeinstituteSchool of Medicine
dc.contributor.unitKoç University Hospital
dc.contributor.unitN/A
dc.contributor.yokid175999
dc.contributor.yokid133091
dc.date.accessioned2024-11-09T23:13:04Z
dc.date.issued2018
dc.description.abstractIntroduction This study was undertaken to assess the intra-and interrater reliability of sonographic thickness measurements of the thenar and hypothenar muscles. Methods: The thickness of the thenar and hypothenar muscles of both hands of 15 volunteers (7 male, 8 female) were evaluated with a 4-13-MHZ linear probe by 2 examiners who were blinded to each other's measurements. Interrater reliability was then evaluated. To assess intrarater reliability, the first examiner also performed a second measurement after an interval of at least 1 day. Results: Mean age of the subjects was 31.169.0 years. Test-retest reliability showed excellent intrarater reliability (intraclass correlation coefficient range: 0.889-0.963) and substantial to excellent results for interrater reliability (intraclass correlation coefficient range: 0.692-0.937). Discussion: We found that ultrasound is a reliable method for thickness measurements of the thenar and hypothenar muscles.
dc.description.indexedbyWoS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.issue1
dc.description.openaccessNO
dc.description.volume57
dc.identifier.doi10.1002/mus.25735
dc.identifier.eissn1097-4598
dc.identifier.issn0148-639X
dc.identifier.scopus2-s2.0-85024479801
dc.identifier.urihttp://dx.doi.org/10.1002/mus.25735
dc.identifier.urihttps://hdl.handle.net/20.500.14288/9921
dc.identifier.wos417762300003
dc.keywordsHand
dc.keywordsHypothenar muscles
dc.keywordsMuscle thickness
dc.keywordsQuantitative ultrasound
dc.keywordsReliability
dc.keywordsThenar muscles
dc.keywordsInflammatory demyelinating polyneuropathy
dc.keywordsPoems syndrome
dc.keywordsBlink reflex
dc.keywordsNeuropathy
dc.keywordsNerves
dc.keywordsMotor
dc.languageEnglish
dc.publisherWiley
dc.sourceMuscle and Nerve
dc.subjectClinical neurology
dc.subjectNeurosciences
dc.titleReliability of sonographic muscle thickness measurements of the thenar and hypothenar muscles
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.authorid0000-0002-4378-5907
local.contributor.authorid0000-0002-2052-6072
local.contributor.kuauthorMısırlıoğlu, Tuğçe Özekli
local.contributor.kuauthorTaşkıran, Özden Özyemişçi

Files