Publication: Reliability of sonographic muscle thickness measurements of the thenar and hypothenar muscles
dc.contributor.coauthor | N/A | |
dc.contributor.department | N/A | |
dc.contributor.kuauthor | Mısırlıoğlu, Tuğçe Özekli | |
dc.contributor.kuauthor | Taşkıran, Özden Özyemişçi | |
dc.contributor.kuprofile | Doctor | |
dc.contributor.kuprofile | Faculty Member | |
dc.contributor.schoolcollegeinstitute | N/A | |
dc.contributor.schoolcollegeinstitute | School of Medicine | |
dc.contributor.unit | Koç University Hospital | |
dc.contributor.unit | N/A | |
dc.contributor.yokid | 175999 | |
dc.contributor.yokid | 133091 | |
dc.date.accessioned | 2024-11-09T23:13:04Z | |
dc.date.issued | 2018 | |
dc.description.abstract | Introduction This study was undertaken to assess the intra-and interrater reliability of sonographic thickness measurements of the thenar and hypothenar muscles. Methods: The thickness of the thenar and hypothenar muscles of both hands of 15 volunteers (7 male, 8 female) were evaluated with a 4-13-MHZ linear probe by 2 examiners who were blinded to each other's measurements. Interrater reliability was then evaluated. To assess intrarater reliability, the first examiner also performed a second measurement after an interval of at least 1 day. Results: Mean age of the subjects was 31.169.0 years. Test-retest reliability showed excellent intrarater reliability (intraclass correlation coefficient range: 0.889-0.963) and substantial to excellent results for interrater reliability (intraclass correlation coefficient range: 0.692-0.937). Discussion: We found that ultrasound is a reliable method for thickness measurements of the thenar and hypothenar muscles. | |
dc.description.indexedby | WoS | |
dc.description.indexedby | Scopus | |
dc.description.indexedby | PubMed | |
dc.description.issue | 1 | |
dc.description.openaccess | NO | |
dc.description.volume | 57 | |
dc.identifier.doi | 10.1002/mus.25735 | |
dc.identifier.eissn | 1097-4598 | |
dc.identifier.issn | 0148-639X | |
dc.identifier.scopus | 2-s2.0-85024479801 | |
dc.identifier.uri | http://dx.doi.org/10.1002/mus.25735 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14288/9921 | |
dc.identifier.wos | 417762300003 | |
dc.keywords | Hand | |
dc.keywords | Hypothenar muscles | |
dc.keywords | Muscle thickness | |
dc.keywords | Quantitative ultrasound | |
dc.keywords | Reliability | |
dc.keywords | Thenar muscles | |
dc.keywords | Inflammatory demyelinating polyneuropathy | |
dc.keywords | Poems syndrome | |
dc.keywords | Blink reflex | |
dc.keywords | Neuropathy | |
dc.keywords | Nerves | |
dc.keywords | Motor | |
dc.language | English | |
dc.publisher | Wiley | |
dc.source | Muscle and Nerve | |
dc.subject | Clinical neurology | |
dc.subject | Neurosciences | |
dc.title | Reliability of sonographic muscle thickness measurements of the thenar and hypothenar muscles | |
dc.type | Journal Article | |
dspace.entity.type | Publication | |
local.contributor.authorid | 0000-0002-4378-5907 | |
local.contributor.authorid | 0000-0002-2052-6072 | |
local.contributor.kuauthor | Mısırlıoğlu, Tuğçe Özekli | |
local.contributor.kuauthor | Taşkıran, Özden Özyemişçi |