Publication:
Reliability of sonographic muscle thickness measurements of the thenar and hypothenar muscles

dc.contributor.departmentSchool of Medicine
dc.contributor.facultymemberYes
dc.contributor.kuauthorMısırlıoğlu, Tuğçe Özekli
dc.contributor.kuauthorTaşkıran, Özden Özyemişçi
dc.contributor.schoolcollegeinstituteSCHOOL OF MEDICINE
dc.date.accessioned2024-11-09T23:13:04Z
dc.date.issued2018
dc.description.abstractIntroduction This study was undertaken to assess the intra-and interrater reliability of sonographic thickness measurements of the thenar and hypothenar muscles. Methods: The thickness of the thenar and hypothenar muscles of both hands of 15 volunteers (7 male, 8 female) were evaluated with a 4-13-MHZ linear probe by 2 examiners who were blinded to each other's measurements. Interrater reliability was then evaluated. To assess intrarater reliability, the first examiner also performed a second measurement after an interval of at least 1 day. Results: Mean age of the subjects was 31.169.0 years. Test-retest reliability showed excellent intrarater reliability (intraclass correlation coefficient range: 0.889-0.963) and substantial to excellent results for interrater reliability (intraclass correlation coefficient range: 0.692-0.937). Discussion: We found that ultrasound is a reliable method for thickness measurements of the thenar and hypothenar muscles.
dc.description.fulltextNo
dc.description.harvestedfromManual
dc.description.indexedbyWOS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.openaccessNO
dc.description.peerreviewstatusN/A
dc.description.publisherscopeInternational
dc.description.readpublishN/A
dc.description.sponsoredbyTubitakEuN/A
dc.description.studentonlypublicationNo
dc.description.studentpublicationNo
dc.description.versionN/A
dc.identifier.WoSQuartileQ2
dc.identifier.doi10.1002/mus.25735
dc.identifier.eissn1097-4598
dc.identifier.embargoN/A
dc.identifier.endpageE17
dc.identifier.issn0148-639X
dc.identifier.issue1
dc.identifier.pubmed28662294
dc.identifier.scopus2-s2.0-85024479801
dc.identifier.startpageE14
dc.identifier.urihttps://doi.org/10.1002/mus.25735
dc.identifier.urihttps://hdl.handle.net/20.500.14288/9921
dc.identifier.volume57
dc.identifier.wos000417762300003
dc.keywordsHand
dc.keywordsHypothenar muscles
dc.keywordsMuscle thickness
dc.keywordsQuantitative ultrasound
dc.keywordsReliability
dc.keywordsThenar muscles
dc.language.isoeng
dc.publisherWiley
dc.relation.affiliationKoç University
dc.relation.collectionKoç University Institutional Repository
dc.relation.ispartofMuscle and Nerve
dc.relation.openaccessN/A
dc.rightsN/A
dc.subjectClinical neurology
dc.subjectNeurosciences
dc.titleReliability of sonographic muscle thickness measurements of the thenar and hypothenar muscles
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.kuauthorMısırlıoğlu, Tuğçe Özekli
local.contributor.kuauthorTaşkıran, Özden Özyemişçi
relation.isOrgUnitOfPublicationd02929e1-2a70-44f0-ae17-7819f587bedd
relation.isOrgUnitOfPublication.latestForDiscoveryd02929e1-2a70-44f0-ae17-7819f587bedd
relation.isParentOrgUnitOfPublication17f2dc8e-6e54-4fa8-b5e0-d6415123a93e
relation.isParentOrgUnitOfPublication.latestForDiscovery17f2dc8e-6e54-4fa8-b5e0-d6415123a93e

Files