Publication: Determination of the optimum absorption coefficient in Cr4+: forsterite lasers under thermal loading: errata
dc.contributor.department | Department of Physics | |
dc.contributor.department | Department of Physics | |
dc.contributor.kuauthor | Sennaroğlu, Alphan | |
dc.contributor.kuauthor | Pekerten, Barış | |
dc.contributor.kuprofile | Faculty Member | |
dc.contributor.kuprofile | Undergraduated Student | |
dc.contributor.other | Department of Physics | |
dc.contributor.schoolcollegeinstitute | College of Sciences | |
dc.contributor.schoolcollegeinstitute | College of Sciences | |
dc.contributor.yokid | 23851 | |
dc.contributor.yokid | N/A | |
dc.date.accessioned | 2024-11-09T23:34:41Z | |
dc.date.issued | 1999 | |
dc.description.abstract | In our recent Letter,[1] in which we analyzed the effects of thermal loading in room-temperature Cr4+:forsterite lasers, a scaling error was made in the best-fit and optimization calculations. In the comparison of theory with experiment (Fig. 2), the correct best-fit value of the stimulated-emission cross section 𝜎𝑒 should have been 0.98×10−19 cm2. In addition, the correct optimum value of the small-signal absorption coefficient that minimizes the incident threshold pump power (see Fig. 3) should have been 0.34 cm−1, corresponding to a net unsaturated pump absorption of 49% for a 2-cm-long crystal. The corrections did not affect any of the trends predicted by the theory. | |
dc.description.indexedby | WoS | |
dc.description.indexedby | Scopus | |
dc.description.indexedby | PubMed | |
dc.description.issue | 13 | |
dc.description.openaccess | NO | |
dc.description.volume | 24 | |
dc.identifier.doi | 10.1364/OL.24.000921 | |
dc.identifier.issn | 0146-9592 | |
dc.identifier.scopus | 2-s2.0-85010130906 | |
dc.identifier.uri | http://dx.doi.org/10.1364/OL.24.000921 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14288/12381 | |
dc.identifier.wos | 81225700021 | |
dc.language | English | |
dc.publisher | Optical Soc Amer | |
dc.source | Optics Letters | |
dc.subject | Optics | |
dc.title | Determination of the optimum absorption coefficient in Cr4+: forsterite lasers under thermal loading: errata | |
dc.type | Other | |
dc.type.other | Correction | |
dspace.entity.type | Publication | |
local.contributor.authorid | 0000-0003-4391-0189 | |
local.contributor.authorid | 0000-0002-5794-9706 | |
local.contributor.kuauthor | Sennaroğlu, Alphan | |
local.contributor.kuauthor | Pekerten, Barış | |
relation.isOrgUnitOfPublication | c43d21f0-ae67-4f18-a338-bcaedd4b72a4 | |
relation.isOrgUnitOfPublication.latestForDiscovery | c43d21f0-ae67-4f18-a338-bcaedd4b72a4 |