Publication:
Pupil steering holographic display for pre-operative vision screening of cataracts

dc.contributor.coauthorUlusoy, Erdem
dc.contributor.departmentDepartment of Electrical and Electronics Engineering
dc.contributor.kuauthorKavaklı, Koray
dc.contributor.kuauthorAydındoğan, Güneş
dc.contributor.kuauthorKesim, Cem
dc.contributor.kuauthorHasanreisoğlu, Murat
dc.contributor.kuauthorŞahin, Afsun
dc.contributor.kuauthorÜrey, Hakan
dc.contributor.kuprofileTeaching Faculty
dc.contributor.kuprofileFaculty Member
dc.contributor.kuprofileFaculty Member
dc.contributor.kuprofileFaculty Member
dc.contributor.otherDepartment of Electrical and Electronics Engineering
dc.contributor.researchcenterKoç University Research Center for Translational Medicine (KUTTAM) / Koç Üniversitesi Translasyonel Tıp Araştırma Merkezi (KUTTAM)
dc.contributor.schoolcollegeinstituteGraduate School of Sciences and Engineering
dc.contributor.schoolcollegeinstituteSchool of Medicine
dc.contributor.schoolcollegeinstituteCollege of Engineering
dc.contributor.unitKoç University Hospital
dc.contributor.yokidN/A
dc.contributor.yokidN/A
dc.contributor.yokidN/A
dc.contributor.yokid182001
dc.contributor.yokid171267
dc.contributor.yokid8579
dc.date.accessioned2024-11-09T13:18:52Z
dc.date.issued2021
dc.description.abstractCataract is the most common cause of preventable blindness and vision loss where the only treatment is surgical replacement of the natural lens with an intraocular lens. Computergenerated holography (CGH) enables to control phase, size, and shape of the light beam entering through the eye-pupil. We developed a holographic vision simulator to assess visual acuity for patients to experience the postoperative corrected vision before going through surgery. A holographically shaped light beam is directed onto the retina using small non-cataractous regions of the lens with the help of a pupil tracker. A Snellen chart hologram is shown to subjects at desired depth with myopia and hyperopia correction. Tests with 13 patients demonstrated substantial improvements in visual acuity and the simulator results are consistent with the post-operative vision tests. Holographic simulator overperforms the existing vision simulators, which are limited to static pinhole exit pupils and incapable of correcting aberrations.
dc.description.fulltextYES
dc.description.indexedbyScopus
dc.description.issue12
dc.description.openaccessYES
dc.description.publisherscopeInternational
dc.description.sponsoredbyTubitakEuEU
dc.description.sponsorshipEuropean Union (EU)
dc.description.sponsorshipHorizon 2020
dc.description.sponsorshipEuropean Research Council (ERC)
dc.description.sponsorshipResearch and Innovation Programme
dc.description.sponsorshipEYECAS, ERC-PoC
dc.description.versionPublisher version
dc.description.volume12
dc.formatpdf
dc.identifier.doi10.1364/BOE.439545
dc.identifier.embargoNO
dc.identifier.filenameinventorynoIR02959
dc.identifier.issn2156-7085
dc.identifier.linkhttps://doi.org/10.1364/BOE.439545
dc.identifier.quartileQ2
dc.identifier.scopus2-s2.0-85119963821
dc.identifier.urihttps://hdl.handle.net/20.500.14288/3050
dc.keywordsVision
dc.keywordsvisual optics
dc.languageEnglish
dc.publisherOptica Publishing Group
dc.relation.grantno899907
dc.relation.urihttp://cdm21054.contentdm.oclc.org/cdm/ref/collection/IR/id/9606
dc.sourceBiomedical Optics Express
dc.subjectOptics
dc.subjectPhotonics
dc.titlePupil steering holographic display for pre-operative vision screening of cataracts
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.authoridN/A
local.contributor.authoridN/A
local.contributor.authoridN/A
local.contributor.authorid0000-0001-9885-5653
local.contributor.authorid0000-0002-5083-5618
local.contributor.authorid0000-0002-2031-7967
local.contributor.kuauthorKavaklı, Koray
local.contributor.kuauthorAydındoğan, Güneş
local.contributor.kuauthorKesim, Cem
local.contributor.kuauthorHasanreisoğlu, Murat
local.contributor.kuauthorŞahin, Afsun
local.contributor.kuauthorÜrey, Hakan
relation.isOrgUnitOfPublication21598063-a7c5-420d-91ba-0cc9b2db0ea0
relation.isOrgUnitOfPublication.latestForDiscovery21598063-a7c5-420d-91ba-0cc9b2db0ea0

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
9606.pdf
Size:
4.16 MB
Format:
Adobe Portable Document Format