<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Publication:
Frost detection and thickness estimation using a transformer-based semantic segmentation model

Loading...
Thumbnail Image

Departments

School / College / Institute

Item type:Organizational Unit,

Program

Organization Authors

Co-Authors

Hassan, Huzzam

Malik, Anjum Naeem

Nawaz, Tahir

Elahi, Hassan

Date

Language

eng

Embargo Status

No

Journal Title

Journal ISSN

Volume Title

Alternative Title

Abstract

Frost accumulation on evaporator surfaces of the refrigeration systems reduces heat transfer efficiency, increases power consumption, and disrupts cooling uniformity. Efficient defrosting based on frost detection and quantification is critical for maintaining the performance and energy efficiency of refrigeration systems. Although several methods with different strategies have been proposed in the literature, accurate frost detection and reliable thickness estimation remain critical challenges. This study presents a novel frost detection and quantification pipeline based on a Transformer-based segmentation model and a data-driven pixel-based regression method. High-resolution RGB images of heat exchangers were captured under controlled refrigeration conditions and preprocessed to create a labeled dataset for model training and validation. The proposed method employs the SegFormer architecture for semantic segmentation, generating precise binary masks that effectively distinguish frost-covered regions from the background. The segmentation achieved a mean accuracy of 93% and a mean Intersection-over-Union (IoU) of 0.875, demonstrating strong generalization across varying frost densities and illumination conditions. For frost thickness estimation, using binary masks from SegFormer, three datadriven formulations were analyzed for quantitative mapping between the normalized frost pixel values (dimensionless) and the experimentally measured frost thickness (mm). The best performance was obtained with the quadratic formulation, achieving an R2 of 0.930 and an error margin of 11.98%. Additionally, comparative evaluation with previous image-processing methods using the same dataset revealed substantial improvement in results.

Source

Publisher

Elsevier

Citation

item.page.haspartof

Source

International Journal of Refrigeration

item.page.ispartofseries

item.page.edition

DOI

10.1016/j.ijrefrig.2026.106899

item.page.datauri

item.page.link

Rights

N/A

Copyrights Note

Rights and licensing

Endorsement

Review

Supplemented By

Referenced By

Related Patent

Related Goal

Google Scholar
Scholar'da Ara ↗
0
Görüntülenme
0
İndirme
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators