Publication:
Periosteal turnover flap for coverage and salvage of exposed deep brain stimulation device

dc.contributor.coauthorYalcin, Can E.
dc.contributor.departmentKUH (Koç University Hospital)
dc.contributor.departmentSchool of Medicine
dc.contributor.kuauthorBağhaki, Semih
dc.contributor.schoolcollegeinstituteKUH (KOÇ UNIVERSITY HOSPITAL)
dc.contributor.schoolcollegeinstituteSCHOOL OF MEDICINE
dc.date.accessioned2025-01-19T10:28:54Z
dc.date.issued2023
dc.description.abstractImplanted deep brain stimulation (DBS) devices are crucial in the treatment of movement disorders. Hardware extrusion is among the most frequent complications of the implantation process and requires reconstruction with well-vascularized tissues. The authors present a case of periosteal turnover flap for coverage of an exposed DBS device. An 11-year-old female patient with spastic cerebral palsy presented with an exposed DBS device located in the right parietal area. The exposed device was covered by a proximally based periosteal flap. Postoperative evaluations at months 1, 2, 3, and 8 revealed no signs of infection or dehiscence. This brief clinical study shows that reconstruction with periosteal turnover flaps is both an easy and excellent choice for secondary closure of exposed DBS devices.
dc.description.indexedbyWOS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.issue8
dc.description.publisherscopeInternational
dc.description.sponsoredbyTubitakEuN/A
dc.description.volume34
dc.identifier.doi10.1097/SCS.0000000000009683
dc.identifier.issn1049-2275
dc.identifier.quartileQ3
dc.identifier.scopus2-s2.0-85175628114
dc.identifier.urihttps://doi.org/10.1097/SCS.0000000000009683
dc.identifier.urihttps://hdl.handle.net/20.500.14288/25780
dc.identifier.wos1160556500003
dc.keywordsFlap coverage
dc.keywordsImplant extrusion
dc.keywordsPeriosteal flap
dc.language.isoeng
dc.publisherLippincott Williams and Wilkins
dc.relation.ispartofJournal of Craniofacial Surgery
dc.subjectSurgery
dc.titlePeriosteal turnover flap for coverage and salvage of exposed deep brain stimulation device
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.kuauthorBağhaki, Semih
local.contributor.kuauthorMazlum, Leo Can
local.publication.orgunit1SCHOOL OF MEDICINE
local.publication.orgunit1KUH (KOÇ UNIVERSITY HOSPITAL)
local.publication.orgunit2KUH (Koç University Hospital)
local.publication.orgunit2School of Medicine
relation.isOrgUnitOfPublicationf91d21f0-6b13-46ce-939a-db68e4c8d2ab
relation.isOrgUnitOfPublicationd02929e1-2a70-44f0-ae17-7819f587bedd
relation.isOrgUnitOfPublication.latestForDiscoveryf91d21f0-6b13-46ce-939a-db68e4c8d2ab
relation.isParentOrgUnitOfPublication055775c9-9efe-43ec-814f-f6d771fa6dee
relation.isParentOrgUnitOfPublication17f2dc8e-6e54-4fa8-b5e0-d6415123a93e
relation.isParentOrgUnitOfPublication.latestForDiscovery055775c9-9efe-43ec-814f-f6d771fa6dee

Files