Publication: Prospective midterm outcomes of the PULSTA self-expandable transcatheter pulmonary valve: the PULSTA CE approval study.
Program
KU-Authors
KU Authors
Co-Authors
Lee, S. Y.
Kim, G. B.
Carminati, M.
Giugno, L.
Çelebi, A.
Yucel, I. K.
Eicken, A.
Ewert, P.
Georgiev, S.
Choi, J. Y.
Editor & Affiliation
Compiler & Affiliation
Translator
Other Contributor
Date
Language
eng
Type
Embargo Status
N/A
Journal Title
Journal ISSN
Volume Title
Alternative Title
Abstract
Patients with congenital or acquired right ventricular outflow tract dysfunction frequently require pulmonary valve replacement and are exposed to repeated surgical interventions due to prosthetic valve degeneration. The PULSTA self-expanding transcatheter pulmonary valve was designed to address a broad spectrum of native and surgically repaired right ventricular outflow tract anatomies. This study reports the midterm safety, hemodynamic performance, and durability outcomes of the prospective, multinational PULSTA CE approval trial (PULSTA Carpentier Edwards). METHODS: This premarket, multicenter, nonrandomized study enrolled 58 patients across 11 centers in 6 countries. Successful PULSTA implantation was achieved in 57 patients (98.3%), including 4 valve-in-valve procedures. Patients were followed for a median duration of 4.1 years. Primary end points included procedural or device-related serious adverse events, hemodynamic improvement, and sustained valve function. RESULTS: At 6 months, cardiac magnetic resonance imaging demonstrated significant reverse right ventricular remodeling, with marked reductions in right ventricular end-diastolic volume index, end-systolic volume index, and pulmonary regurgitation fraction (all P CONCLUSIONS: The PULSTA transcatheter pulmonary valve demonstrated high procedural success, durable valve function, and sustained hemodynamic benefits. Its adaptability to diverse right ventricular outflow tract anatomies and favorable safety profile supports its role as an effective therapeutic option for patients with right ventricular outflow tract dysfunction. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03983512.
Source
Publisher
Wolters Kluwer Health
Subject
Health sciences, Medicine
Citation
Has Part
Source
Circulation: Cardiovascular Interventions
Book Series Title
Edition
DOI
10.1161/circinterventions.126.016616
item.page.datauri
Link
Rights
N/A
Copyrights Note
Creative Commons license
Except where otherwised noted, this item's license is described as N/A