Publication: EMBC special issue: neural style transfer-based denoising of seismocardiogram signals under dynamic conditions
Program
KU-Authors
KU Authors
Co-Authors
Editor & Affiliation
Compiler & Affiliation
Translator
Other Contributor
Date
Language
eng
Type
Embargo Status
N/A
Journal Title
Journal ISSN
Volume Title
Alternative Title
Abstract
Seismocardiogram (SCG) signals capture the mechanical dynamics of cardiac activity, but their clinical utility is severely limited by motion artifacts during ambulatory monitoring. To overcome this challenge, we propose a neural style transfer (NST)-based denoising framework that converts motion-contaminated SCG recordings into morphology-preserving, rest-like representations. Our method leverages time-frequency spectrograms obtained from continuous wavelet transforms and a pre-trained convolutional neural network (VGG19) to suppress exercise-induced distortions while maintaining physiologically relevant timing and morphology. Across 20 participants, the proposed approach substantially enhanced signal fidelity, improving signal-to-noise ratio and peak signal-to-noise ratio by 176.7% and 152.1%, respectively, and reducing mean squared error and mean absolute error by 95.1% and 83.6%. Structural similarity increased by 70.3%, and correlation with the resting reference more than doubled. Heart rate estimated from denoised signals showed excellent agreement with electrocardiogram measurements, yielding an average error of only 0.89 beats per minute (0.73%). Furthermore, comparative evaluation demonstrated that the proposed restyling and denoising approach consistently outperformed state-of-the-art denoising techniques-including empirical mode decomposition variants, variational mode decomposition, Savitzky-Golay filtering, moving-average filtering, and wavelet-based reconstruction-achieving the lowest heart rate estimation error (0.89 bpm RMSE). Additionally, a controlled simulation confirmed the framework's restyling capability under known ground-truth conditions, yielding a heart rate estimation error of only 0.15 bpm relative to the true reference. These results demonstrate that neural style transfer enables physiology-consistent reconstruction of cardiac mechanical signals in dynamic conditions and represents a highly promising direction toward motion-resilient wearable cardiac monitoring.
Source
Publisher
IEEE
Subject
Physical sciences, Engineering, Biomedical engineering, Health sciences, Medicine, Pulmonary and respiratory medicine, Cardiology and cardiovascular medicine
Citation
Has Part
Source
IEEE Transactions on Biomedical Engineering
Book Series Title
Edition
DOI
10.1109/tbme.2026.3688416
item.page.datauri
Link
Rights
N/A
Copyrights Note
Creative Commons license