Publication:
Cemented radial head arthroplasty: does radiographic loosening have an effect on clinical and functional outcomes? average 10 years' results

Placeholder

Departments

Organizational Unit

School / College / Institute

Organizational Unit
SCHOOL OF MEDICINE
Upper Org Unit

Program

KU Authors

Co-Authors

Pehlivanoglu, Tuna
Ersen, Ali
Bayram, Serkan
Atalar, Ata Can

Publication Date

Language

Embargo Status

Journal Title

Journal ISSN

Volume Title

Alternative Title

Abstract

Purpose The aim of this study was to evaluate the possible effect of radiographic loosening on clinical and functional outcomes, while presenting the mid-term radiographic and functional outcomes of cemented, monopolar RHA applied to patients with comminuted radial head fractures. Methods We performed a retrospective study by evaluating the records of patients who were diagnosed in a single center with radial head fractures between 2001 and 2013. Twenty-six patients with comminuted radial head fractures with a mean age of 48.9 and a mean follow-up time of 132.2 months were included. The radiographic evaluation was performed by assessing peri-prosthetic radiolucent lines around the stem to evaluate loosening, while the clinical evaluation was performed by utilizing elbow range of motion (ROM), Mayo elbow performance score (MEPS), Oxford elbow score (OES) and quick-DASH scores. Results 13 patients (Group 1) with peri-prosthetic stem lucency were defined as radiographic loosening (50%), while the remaining 13 patients (Group 2) were not detected to have stem lucency. One patient in group 1 also had concomitant pain and underwent removal of the prosthesis, while 12 patients (92.3%) remained pain-free. On the latest follow-up visit, there was no significant difference between the groups regarding ROM, MEPS, OES and quick-DASH scores. Conclusions Within ten years following surgery, half of the patients with radial head prostheses were noted to show radiographic signs of loosening which did not have any major negative effect in terms of clinical-functional outcomes and quality of life, except requiring the removal of the implant in one patient.

Source

Publisher

Springer

Subject

Orthopedics, Surgery

Citation

Has Part

Source

European Journal of Orthopaedic Surgery and Traumatology

Book Series Title

Edition

DOI

10.1007/s00590-021-03129-3

item.page.datauri

Link

Rights

Copyrights Note

Endorsement

Review

Supplemented By

Referenced By

0

Views

0

Downloads

View PlumX Details