Publication:
Interobserver reproducibility of intracranial anatomy assessment during second trimester sonographic scan

dc.contributor.coauthorYüce, T.
dc.contributor.coauthorAslan, B.
dc.contributor.coauthorÖzkavukçu, E.
dc.contributor.coauthorKoç, A.
dc.contributor.coauthorSöylemez F.
dc.contributor.departmentSchool of Medicine
dc.contributor.kuauthorKalafat, Erkan
dc.contributor.schoolcollegeinstituteSCHOOL OF MEDICINE
dc.date.accessioned2024-11-09T12:25:57Z
dc.date.issued2021
dc.description.abstractTo evaluate the reproducibility of mid-trimester intracranial anatomy assessment. Women undergoing mid-trimester scan (between 18th to 25th gestational weeks) for fetal anatomy assessment were included in the study. Measurements of lateral ventricle (LV), cisterna magna (CM) and transverse cerebellar diameter (TCD) were obtained for reproducibility analyses. Inter-observer reproducibility analysis was made with correlation coefficients. A total of 162 women were included in the analysis while one woman was excluded from the study due to diagnosis of vermian agenesis. Correlation coefficient (CC) of cisterna magna measurements have shown weak to moderate interclass correlation (r=0.28, P=0.001). Measurements of lateral ventricle have shown moderate to strong interclass correlation (r=0.73, P<0.0001). Transverse cerebellar diameter measurements have shown the best interclass correlation (r=0.88, respectively P<0.0001). Mean difference between different observers were-0.4 mm (95% CI:-3.0 to 2.1 mm), 0.7mm (95% CI:-1.0 to 2.5 mm) and 0.53 mm (95% CI:-2.5 to 3.6 mm) for measurements of cerebellum, lateral ventricle and cisterna magna, respectively. When grouped according to BMI (Over 30 kg/m2 and lower than 25 kg/m2) and presentation (cephalic and breech), there were no differences between groups regarding the prevalence of an absolute difference gre ater than 1 mm between paired measurements by different observers. Measurements of TCD, LV and CM during mid-trimester scan have good interobserver reliability with the exception of CM measurements. Methods used for measuring these structures have shown good consistency between different BMI categories and different fetal presentations during ultrasound scans.
dc.description.fulltextYES
dc.description.indexedbyScopus
dc.description.indexedbyTR Dizin
dc.description.issue4
dc.description.openaccessYES
dc.description.publisherscopeNational
dc.description.sponsoredbyTubitakEuN/A
dc.description.sponsorshipN/A
dc.description.versionPublisher version
dc.description.volume26
dc.identifier.doi10.5505/ejm.2021.83788
dc.identifier.embargoNO
dc.identifier.filenameinventorynoIR03269
dc.identifier.issn1301-0883
dc.identifier.quartileN/A
dc.identifier.scopus2-s2.0-85117771953
dc.identifier.urihttps://doi.org/10.5505/ejm.2021.83788
dc.keywordsAgreement
dc.keywordsAtrium
dc.keywordsCisterna magna
dc.keywordsCorrelation
dc.keywordsLateral ventricle
dc.keywordsReliability
dc.keywordsRescan
dc.keywordsRoutine
dc.keywordsScan
dc.language.isoeng
dc.publisherYüzüncü Yıl Üniversitesi Tıp Fakultesi
dc.relation.grantnoNA
dc.relation.ispartofEastern Journal of Medicine
dc.relation.urihttp://cdm21054.contentdm.oclc.org/cdm/ref/collection/IR/id/10052
dc.subjectNervous system malformations
dc.subjectMagnetic resonance imaging
dc.subjectPrenatal diagnosis
dc.titleInterobserver reproducibility of intracranial anatomy assessment during second trimester sonographic scan
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.kuauthorKalafat, Erkan
local.publication.orgunit1SCHOOL OF MEDICINE
local.publication.orgunit2School of Medicine
relation.isOrgUnitOfPublicationd02929e1-2a70-44f0-ae17-7819f587bedd
relation.isOrgUnitOfPublication.latestForDiscoveryd02929e1-2a70-44f0-ae17-7819f587bedd
relation.isParentOrgUnitOfPublication17f2dc8e-6e54-4fa8-b5e0-d6415123a93e
relation.isParentOrgUnitOfPublication.latestForDiscovery17f2dc8e-6e54-4fa8-b5e0-d6415123a93e

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
10052.pdf
Size:
480.84 KB
Format:
Adobe Portable Document Format