Publication:
Correlation of clinical aqueous flare grading to semi-automated flare measurements using laser flare photometry

dc.contributor.coauthorHalim, Muhammad Sohail
dc.contributor.coauthorOnghanseng, Neil
dc.contributor.coauthorTran, Anh N. T.
dc.contributor.coauthorHassan, Muhammad
dc.contributor.coauthorYilmaz, Mervenur
dc.contributor.coauthorSegawa, Asadu
dc.contributor.coauthorGurelik, Gokhan
dc.contributor.coauthorAfridi, Rubbia
dc.contributor.coauthorOrmaechea, Maria Soledad
dc.contributor.coauthorUludag, Gunay
dc.contributor.coauthorNguyen, Nam, V
dc.contributor.coauthorBae, Jeong Hun
dc.contributor.coauthorPark, Jung Huynh
dc.contributor.coauthorDo, Diana, V
dc.contributor.coauthorIbrahim, Mohamed A.
dc.contributor.coauthorSepah, Yasir J.
dc.contributor.coauthorQuan Dong Nguyen
dc.contributor.departmentKUTTAM (Koç University Research Center for Translational Medicine)
dc.contributor.departmentSchool of Medicine
dc.contributor.kuauthorHasanreisoğlu, Murat
dc.contributor.kuauthorKesim, Cem
dc.contributor.schoolcollegeinstituteResearch Center
dc.contributor.schoolcollegeinstituteSCHOOL OF MEDICINE
dc.date.accessioned2024-11-09T23:50:51Z
dc.date.issued2022
dc.description.abstractPurpose: To compare laser flare photometry (LFP) measurements of aqueous flare with Standardization of Uveitis Nomenclature (SUN) and modified SUN grading.Methods: In this prospective study with multicenter design, uveitis patients were classified according to SUN and modified SUN grading scales. LFP was performed with Kowa FM-700 flaremeter. Mean LFP values were compared with SUN and MSUN scores.Results: The study included 475 LFP measurements, of which 216, 48, 150, 31, 28 and 2 had 0, 0.5+, 1+, 1.5 +, 2+ and 3+ flare, respectively. LFP values were significantly different between each two consecutive steps for both clinical gradings (all P < .05). Cut-off values for modified SUN grading steps were defined as 5.7, 9.7, 15.7 and 43.2 for 0/0.5+, 0.5+/ 1+, 1+/1.5+ and 1.5/2+ borders of clinical flare, respectively.Conclusions: LFP proves to be an objective measurement in analyzing aqueous flare comparable to both SUN and MSUN clinical grading systems.
dc.description.indexedbyWOS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.issue45145
dc.description.openaccessNO
dc.description.publisherscopeInternational
dc.description.sponsoredbyTubitakEuN/A
dc.description.sponsorshipResearch to Prevent Blindness Departmental Challenge Award
dc.description.sponsorshipNational Eye Institute of the National Institutes of Health [P30 EY026877] Research to Prevent Blindness Departmental Challenge Award (Stanford)
dc.description.sponsorshipNational Eye Institute of the National Institutes of Health (P30 EY026877) provide funding for research to Byers Eye Institute at Stanford.
dc.description.volume30
dc.identifier.doi10.1080/09273948.2021.1971723
dc.identifier.eissn1744-5078
dc.identifier.issn0927-3948
dc.identifier.quartileQ2
dc.identifier.scopus2-s2.0-85124077357
dc.identifier.urihttps://doi.org/10.1080/09273948.2021.1971723
dc.identifier.urihttps://hdl.handle.net/20.500.14288/14610
dc.identifier.wos750120200001
dc.keywordsLaser flare meter
dc.keywordsAqueous flare
dc.keywordsClinical flare grading
dc.keywordsMonitor inflammation
dc.keywordsUveitis
dc.keywordsClassification
dc.keywordsSensitivity
dc.language.isoeng
dc.publisherTaylor & Francis
dc.relation.ispartofOcular Immunology and Inflammation
dc.subjectOphthalmology
dc.titleCorrelation of clinical aqueous flare grading to semi-automated flare measurements using laser flare photometry
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.kuauthorHasanreisoğlu, Murat
local.contributor.kuauthorKesim, Cem
local.publication.orgunit1SCHOOL OF MEDICINE
local.publication.orgunit1Research Center
local.publication.orgunit2KUTTAM (Koç University Research Center for Translational Medicine)
local.publication.orgunit2School of Medicine
relation.isOrgUnitOfPublication91bbe15d-017f-446b-b102-ce755523d939
relation.isOrgUnitOfPublicationd02929e1-2a70-44f0-ae17-7819f587bedd
relation.isOrgUnitOfPublication.latestForDiscovery91bbe15d-017f-446b-b102-ce755523d939
relation.isParentOrgUnitOfPublicationd437580f-9309-4ecb-864a-4af58309d287
relation.isParentOrgUnitOfPublication17f2dc8e-6e54-4fa8-b5e0-d6415123a93e
relation.isParentOrgUnitOfPublication.latestForDiscoveryd437580f-9309-4ecb-864a-4af58309d287

Files