Research Outputs
Permanent URI for this communityhttps://hdl.handle.net/20.500.14288/2
Browse
20 results
Search Results
Publication Open Access A cartridge based sensor array platform for multiple coagulation measurements from plasma(Royal Society of Chemistry (RSC), 2015) Bulut, Serpil; Yaralioglu, G. G.; Department of Electrical and Electronics Engineering; Department of Molecular Biology and Genetics; Department of Chemical and Biological Engineering; Çakmak, Onur; Ermek, Erhan; Kılınç, Necmettin; Barış, İbrahim; Kavaklı, İbrahim Halil; Ürey, Hakan; PhD Student; Other; Researcher; Teaching Faculty; Faculty Member; Department of Electrical and Electronics Engineering; Department of Molecular Biology and Genetics; Department of Chemical and Biological Engineering; College of Engineering; Graduate School of Sciences and Engineering; College of Sciences; N/A; 109991; N/A; 111629; 40319; 8579This paper proposes a MEMS-based sensor array enabling multiple clot-time tests for plasma in one disposable microfluidic cartridge. The versatile LoC (Lab-on-Chip) platform technology is demonstrated here for real-time coagulation tests (activated Partial Thromboplastin Time (aPTT) and Prothrombin Time (PT)). The system has a reader unit and a disposable cartridge. The reader has no electrical connections to the cartridge. This enables simple and low-cost cartridge designs and avoids reliability problems associated with electrical connections. The cartridge consists of microfluidic channels and MEMS microcantilevers placed in each channel. The microcantilevers are made of electroplated nickel. They are actuated remotely using an external electro-coil and the read-out is also conducted remotely using a laser. The phase difference between the cantilever oscillation and the coil drive is monitored in real time. During coagulation, the viscosity of the blood plasma increases resulting in a change in the phase read-out. The proposed assay was tested on human and control plasma samples for PT and aPTT measurements. PT and aPTT measurements from control plasma samples are comparable with the manufacturer's datasheet and the commercial reference device. The measurement system has an overall 7.28% and 6.33% CV for PT and aPTT, respectively. For further implementation, the microfluidic channels of the cartridge were functionalized for PT and aPTT tests by drying specific reagents in each channel. Since simultaneous PT and aPTT measurements are needed in order to properly evaluate the coagulation system, one of the most prominent features of the proposed assay is enabling parallel measurement of different coagulation parameters. Additionally, the design of the cartridge and the read-out system as well as the obtained reproducible results with 10 mu l of the plasma samples suggest an opportunity for a possible point-of-care application.Publication Metadata only A communication theoretical modeling of axonal propagation in hippocampal pyramidal neurons(IEEE-Inst Electrical Electronics Engineers Inc, 2017) N/A; N/A; Department of Electrical and Electronics Engineering; Ramezani, Hamideh; Akan, Özgür Barış; PhD Student; Faculty Member; Department of Electrical and Electronics Engineering; Graduate School of Sciences and Engineering; College of Engineering; N/A; 6647Understandingthe fundamentals of communication among neurons, known as neuro-spike communication, leads to reach bio-inspired nanoscale communication paradigms. In this paper, we focus on a part of neuro-spike communication, known as axonal transmission, and propose a realistic model for it. The shape of the spike during axonal transmission varies according to previously applied stimulations to the neuron, and these variations affect the amount of information communicated between neurons. Hence, to reach an accurate model for neuro-spike communication, the memory of axon and its effect on the axonal transmission should be considered, which are not studied in the existing literature. In this paper, we extract the important factors on the memory of axon and define memory states based on these factors. We also describe the transition among these states and the properties of axonal transmission in each of them. Finally, we demonstrate that the proposed model can follow changes in the axonal functionality properly by simulating the proposed model and reporting the root mean square error between simulation results and experimental data.Publication Metadata only A fast algorithm for analysis of molecular communication in artificial synapse(IEEE-Inst Electrical Electronics Engineers Inc, 2017) N/A; Department of Electrical and Electronics Engineering; Bilgin, Bilgesu Arif; Akan, Özgür Barış; PhD Student; Faculty Member; Department of Electrical and Electronics Engineering; Graduate School of Sciences and Engineering; College of Engineering; N/A; 6647In this paper, we analyze molecular communications (MCs) in a proposed artificial synapse (AS), whose main difference from biological synapses (BSs) is that it is closed, i.e., transmitter molecules cannot diffuse out from AS. Such a setup has both advantages and disadvantages. Besides higher structural stability, being closed, AS never runs out of transmitters. Thus, MC in AS is disconnected from outer environment, which is very desirable for possible intra-body applications. On the other hand, clearance of transmitters from AS has to be achieved by transporter molecules on the presynaptic membrane of AS. Except from these differences, rest of AS content is taken to be similar to that of a glutamatergic BS. Furthermore, in place of commonly used Monte Carlo-based random walk experiments, we derive a deterministic algorithm that attacks for expected values of desired parameters such as evolution of receptor states. To assess validity of our algorithm, we compare its results with average results of an ensemble of Monte Carlo experiments, which shows near exact match. Moreover, our approach requires significantly less amount of computation compared with Monte Carlo approach, making it useful for parameter space exploration necessary for optimization in design of possible MC devices, including but not limited to AS. Results of our algorithm are presented in case of single quantal release only, and they support that MC in closed AS with elevated uptake has similar properties to that in BS. In particular, similar to glutamatergic BSs, the quantal size and the density of receptors are found to be main sources of synaptic plasticity. On the other hand, the proposed model of AS is found to have slower decaying transients of receptor states than BSs, especially desensitized ones, which is due to prolonged clearance of transmitters from AS.Publication Metadata only Analysis of information flow in miso neuro-spike communication channel with synaptic plasticity(Institute of Electrical and Electronics Engineers (IEEE), 2018) Ramezani H.; Muzio G.; N/A; Department of Electrical and Electronics Engineering; Khan, Tooba; Akan, Özgür Barış; PhD Student; Faculty Member; Department of Electrical and Electronics Engineering; Graduate School of Sciences and Engineering; College of Engineering; N/A; 6647Communication among neurons is the most promising technique for biocompatible nanonetworks. This necessitates the thorough communication theoretical analysis of information transmission among neurons. The information flow in neuro-spike communication channel is regulated by the ability of neurons to change their synaptic strengths over time, i.e. synaptic plasticity. Thus, the performance evaluation of the nervous nanonetwork is incomplete without considering the influence of synaptic plasticity. Hence, in this paper, we provide a comprehensive model for multiple-input single-output (MISO) neuro-spike communication by integrating the spike timing dependent plasticity (STDP) into existing channel model. We simulate this model for a realistic scenario with correlated inputs and varying spiking threshold. We show that plasticity is strengthening the correlated input synapses at the expense of weakening the synapses with uncorrelated inputs. Moreover, a nonlinear behavior in signal transmission is observed with changing spiking threshold.Publication Open Access Applications of augmented reality in ophthalmology [invited](Optical Society of America (OSA), 2021) Artal, Pablo; Department of Physics; Department of Electrical and Electronics Engineering; Aydındoğan, Güneş; Kavaklı, Koray; Ürey, Hakan; Şahin, Afsun; Faculty Member; Faculty Member; Department of Physics; Department of Electrical and Electronics Engineering; Koç University Research Center for Translational Medicine (KUTTAM) / Koç Üniversitesi Translasyonel Tıp Araştırma Merkezi (KUTTAM); Graduate School of Sciences and Engineering; College of Engineering; School of Medicine; N/A; N/A; 8579; 171267Throughout the last decade, augmented reality (AR) head-mounted displays (HMDs) have gradually become a substantial part of modern life, with increasing applications ranging from gaming and driver assistance to medical training. Owing to the tremendous progress in miniaturized displays, cameras, and sensors, HMDs are now used for the diagnosis, treatment, and follow-up of several eye diseases. In this review, we discuss the current state-of-the-art as well as potential uses of AR in ophthalmology. This review includes the following topics: (i) underlying optical technologies, displays and trackers, holography, and adaptive optics; (ii) accommodation, 3D vision, and related problems such as presbyopia, amblyopia, strabismus, and refractive errors; (iii) AR technologies in lens and corneal disorders, in particular cataract and keratoconus; (iv) AR technologies in retinal disorders including age-related macular degeneration (AMD), glaucoma, color blindness, and vision simulators developed for other types of low-vision patients.Publication Metadata only Asymmetrical relaying in molecular communications(IEEE-Inst Electrical Electronics Engineers Inc, 2022) Pusane, Ali E.; Yılmaz, H. Birkan; Tuğcu, Tuna; N/A; Department of Electrical and Electronics Engineering; Angjo, Joana; Başar, Ertuğrul; Master Student; Faculty Member; Department of Electrical and Electronics Engineering; Graduate School of Sciences and Engineering; College of Engineering; N/A; 149116Molecular communication via diffusion (MCvD) is a novel communication technique that uses the diffusive characteristics of molecules for enabling the communication between nanomachines. Since the molecules propagate following a random motion, MCvD schemes are usually limited to a short communication range. Most of the molecular relaying schemes in the literature consider symmetric setups where transmitters and receivers are placed at the same distance from the relay, which is difficult to provide in practical scenarios and a possible cause of failure. In this study, asymmetric molecular links of a relay system are investigated. In order to achieve a satisfactory overall performance in spite of the asymmetries, two parameter optimization methods are proposed for the uplink of a relaying system, based on emitting different types of molecules with different diffusion coefficient values from the transmitters. Due to the channel symmetry, the solutions presented in this study are expected to hold for the downlink as well. The resulting bit error rate (BER) performances are presented and discussed.Publication Metadata only Diffusion-based model for synaptic molecular communication channel(IEEE-Inst Electrical Electronics Engineers Inc, 2017) N/A; N/A; N/A; Department of Electrical and Electronics Engineering; Khan, Tooba; Bilgin, Bilgesu Arif; Akan, Özgür Barış; PhD Student; PhD Student; Faculty Member; Department of Electrical and Electronics Engineering; Graduate School of Sciences and Engineering; Graduate School of Sciences and Engineering; College of Engineering; N/A; N/A; 6647Computational methods have been extensively used to understand the underlying dynamics of molecular communication methods employed by nature. One very effective and popular approach is to utilize a Monte Carlo simulation. Although it is very reliable, this method can have a very high computational cost, which in some cases renders the simulation impractical. Therefore, in this paper, for the special case of an excitatory synaptic molecular communication channel, we present a novel mathematical model for the diffusion and binding of neurotransmitters that takes into account the effects of synaptic geometry in 3-D space and re-absorption of neurotransmitters by the transmitting neuron. Based on this model we develop a fast deterministic algorithm, which calculates expected value of the output of this channel, namely, the amplitude of excitatory postsynaptic potential (EPSP), for given synaptic parameters. We validate our algorithm by a Monte Carlo simulation, which shows total agreement between the results of the two methods. Finally, we utilize our model to quantify the effects of variation in synaptic parameters, such as position of release site, receptor density, size of postsynaptic density, diffusion coefficient, uptake probability, and number of neurotransmitters in a vesicle, on maximum number of bound receptors that directly affect the peak amplitude of EPSP.Publication Open Access Efficient photocapacitors via ternary hybrid photovoltaic optimization for photostimulation of neurons(Optical Society of America (OSA), 2020) Department of Electrical and Electronics Engineering; Srivastava, Shashi Bhushan; Melikov, Rustamzhon; Yıldız, Erdost; Han, Mertcan; Şahin, Afsun; Nizamoğlu, Sedat; Researcher; PhD Student; PhD Student; Master Student; Faculty Member; Faculty Member; Department of Electrical and Electronics Engineering; Graduate School of Sciences and Engineering; Graduate School of Health Sciences; School of Medicine; College of Engineering; N/A; N/A; N/A; N/A; 171267; 130295Optoelectronic photoelectrodes based on capacitive charge-transfer offer an attractive route to develop safe and effective neuromodulators. Here, we demonstrate efficient optoelectronic photoelectrodes that are based on the incorporation of quantum dots (QDs) into poly(3-hexylthiophene-2,5-diyl) (P3HT) and [6,6]-Phenyl-C61-butyric acid methyl ester (PCBM) bulk heterojunction. We control the performance of the photoelectrode by the blend ratio, thickness, and nanomorphology of the ternary bulk heterojunction. The optimization led to a photocapacitor that has a photovoltage of 450 mV under a light intensity level of 20 mW.cm(-2) and a responsivity of 99 mA/W corresponding to the most light-sensitive organic photoelectrode reported to date. The photocapacitor can facilitate action potential generation by hippocampal neurons via burst waveforms at an intensity level of 20 mW.cm(-2). Therefore, the results point to an alternative direction in the engineering of safe and ultra-light-sensitive neural interfaces.Publication Metadata only FRET-based nanoscale point-to-point and broadcast communications with multi-exciton transmission and channel routing(Ieee-Inst Electrical Electronics Engineers Inc, 2014) N/A; N/A; Department of Electrical and Electronics Engineering; Kuşcu, Murat; Akan, Özgür Barış; PhD Student; Faculty Member; Department of Electrical and Electronics Engineering; Graduate School of Sciences and Engineering; College of Engineering; 316349; 6647Nanoscale communication based on Forster Resonance Energy Transfer (FRET) enables nanoscale single molecular devices to communicate with each other utilizing excitons generated on fluorescentmolecules as information carriers. Based on the point-to-point single-exciton FRET-based nanocommunication model, we investigate the multiple-exciton case for point-to-point and broadcast communications following an information theoretical approach and conducting simulations through Monte Carlo approach. We demonstrate that the multi-exciton transmission significantly improves the channel reliability and the range of the communication up to tens of nanometers for immobile nanonodes providing high data transmission rates. Furthermore, our analyses indicate that multi-exciton transmission enables broadcasting of information from a transmitter nanonode to many receiver nanonodes pointing out the potential of FRET-based communication to extend over nanonetworks. In this study, we also propose electrically and chemically controllable routing mechanisms exploiting the strong dependence of FRET rate on spectral and spatial characteristics of fluorescent molecules. We show that the proposed routing mechanisms enable the remote control of information flow in FRET-based nanonetworks. The high transmission rates obtained by multi-exciton scheme for point-to-point and broadcast communications, as well as the routing opportunities make FRET-based communication promising for future molecular computers.Publication Metadata only Impact of long term plasticity on information transmission over neuronal networks(Institute of Electrical and Electronics Engineers (IEEE), 2020) Ramezani, Hamideh; Abbasi, Naveed A.; N/A; Department of Electrical and Electronics Engineering; Khan, Tooba; Akan, Özgür Barış; PhD Student; Faculty Member; Department of Electrical and Electronics Engineering; Graduate School of Sciences and Engineering; College of Engineering; N/A; 6647The realization of bio-compatible nanomachines would pave the way for developing novel diagnosis and treatment techniques for the dysfunctions of intra-body nanonetworks and revolutionize the traditional healthcare methodologies making them less invasive and more efficient. The network of these nanomachines is aimed to be used for treating neuronal diseases such as developing an implant that bridges over the injured spinal cord to regain its normal functionality. Thus, nanoscale communication paradigms are needed to be investigated to facilitate communication between nanomachines. Communication among neurons is one of the most promising nanoscale communication paradigm, which necessitates the thorough communication theoretical analysis of information transmission among neurons. The information flow in neuro-spike communication channel is regulated by the ability of neurons to change synaptic strengths over time, i.e. synaptic plasticity. Thus, the performance evaluation of the nervous nanonetwork is incomplete without considering the influence of synaptic plasticity. In this paper, we focus on information transmission among hippocampal pyramidal neurons and provide a comprehensive channel model for MISO neuro-spike communication, which includes axonal transmission, vesicle release process, synaptic communication and spike generation. In this channel, the spike timing dependent plasticity (STDP) model is used to cover both synaptic depressiofan and potentiation depending on the temporal correlation between spikes generated by input and output neurons. Since synaptic strength changes depending on different physiological factors such as spiking rate of presynaptic neurons, number of correlated presynaptic neurons and the correlation factor among them, we simulate this model with correlated inputs and analyze the evolution of synaptic weights over time. Moreover, we calculate average mutual information between input and output of the channel and find the impact of plasticity and correlation among inputs on the information transmission. The simulation results reveal the impact of different physiological factors related to either presynaptic or postsynaptic neurons on the performance of MISO neuro-spike communication. Moreover, they provide guidelines for selecting the system parameters in a bio-inspired neuronal network according to the requirements of different applications.