Research Project:
Optimum Hemodinamik Performanslı Sağlam Çift Lümenli "Ecmo" Kanül Dizaynı

Loading...
Project Logo

Contributors

Funders

ID

TB.00462

Authors

Person
Pekkan, Kerem
Faculty Member

Publications

Placeholder
Publication
Hemodynamics of neonatal double lumen cannula malposition
(2020) Çakmak, Bilgesu; Jamil, Muhammad; Pekkan, Kerem; Rasooli, Reza; Rezaeimoghaddam, Mohammad; Yıldız, Yahya; Salihoğlu, Ece; Department of Mechanical Engineering; Yes; College of Engineering
 Objective: Malposition of dual lumen cannula is a frequent and challenging complication in neonates and plays a significant role in shaping the in vitro device hemodynamics. This study aims to analyze the effect of the dual lumen cannula malposition on right-atrial hemodynamics in neonatal patients using an experimentally validated computational fluid dynamics model. Methods: A computer model was developed for clinically approved dual lumen cannula (13Fr Origen Biomedical, Austin, Texas, USA) oriented inside the atrium of a 3-kg neonate with normal venous return. Atrial hemodynamics and dual lumen cannula malposition were systematically simulated for two rotations (antero-atrial and atrio-septal) and four translations (two intravascular movements along inferior vena cava and two dislodged configurations in the atrium). A multi-domain compartmentalized mesh was prepared to allow the site-specific evaluation of important hemodynamic parameters. Transport of each blood stream, blood damage levels, and recirculation times are quantified and compared to dual lumen cannula in proper position. Results: High recirculation levels (39 ± 4%) in malpositioned cases resulted in poor oxygen saturation where maximum recirculation of up to 42% was observed. Apparently, Origen dual lumen cannula showed poor inferior vena cava bloodcapturing efficiency (48 ± 8%) but high superior vena cava blood–capturing efficiency (86 ± 10%). Dual lumen cannula malposition resulted in corresponding changes in residence time (1.7 ± 0.5 seconds through the tricuspid). No significant differences in blood damage were observed among the simulated cases compared to normal orientation. Compared to the correct dual lumen cannula position, both rotational and translational displacements of the dual lumen cannula resulted in significant hemodynamic differences. Conclusion: Rotational or translational movement of dual lumen cannula is the determining factor for atrial hemodynamics, venous capturing efficiency, blood residence time, and oxygenated blood delivery. Results obtained through computational fluid dynamics methodology can provide valuable foresight in assessing the performance of the dual lumen cannula in patient-specific configurations.
Thumbnail Image
PublicationOpen Access
Estimation of pulsatile energy dissipation in intersecting pipe junctions using inflow pulsatility indices
(American Institute of Physics (AIP) Publishing, 2021) Pekkan, Kerem; Rasooli, Reza; Dur, Onur; Department of Mechanical Engineering; Graduate School of Health Sciences; Yes; College of Engineering; GRADUATE SCHOOL OF HEALTH SCIENCES
This study aims to characterize the effect of inflow pulsatility on the hydrodynamic power loss inside intersecting double-inlet, double-outlet pipe intersection (DIPI) with cross-flow mixing. An extensive set of computational fluid dynamics (CFD) simulations was performed in order to identify the individual effects of flow pulsatility parameters, i.e., amplitude, frequency, and relative phase shift between the inflow waveform oscillations, on power loss. An experimentally validated second order accurate solver is employed in this study. To predict the pulsatile flow performance of any given arbitrary inflow waveforms, we proposed three easy-to-calculate pulsatility indices. The frequency-coupled quasi-steady flow theory is incorporated to identify the functional form of pulsatile power loss as a function of these indices. Our results indicated that the power loss within the inflow branch sections, lumped outflow-junction section, and the whole conduit correlates strongly with the pulsatility of each inflow waveform, the total inflow pulsatility, and inflow frequency content, respectively. The complete CFD simulation matrix provided a unified analytical expression that predicts pulsatile power loss inside a one-degree offset DIPI geometry. The predictive accuracy of this expression is evaluated in comparison to the CFD evaluation of arbitrary multi-harmonic inflow waveforms. These results have important implications on hydrodynamic pipe networks that employ complex junctions as well as in the patient-to-patient comparison of surgically created vascular connections. Coupling the present analytical pulsatile power loss expression with non-dimensional steady power loss formulation provided a valuable predictive tool to estimate the pulsatile energy dissipation for any arbitrary junction geometry with minimum use of the costly CFD computations.