Publication:
Lumbar single-level dynamic stabilization with semi-rigid and full dynamic systems: a retrospective clinical and radiological analysis of 71 patients

dc.contributor.coauthorYilmaz, A.
dc.contributor.coauthorErbulut, D.U.
dc.contributor.departmentSchool of Medicine
dc.contributor.kuauthorEgemen, Emrah
dc.contributor.kuauthorÖktenoğlu, Bekir Tunç
dc.contributor.kuauthorÖzer, Ali Fahir
dc.contributor.kuauthorSasani, Mehdi
dc.contributor.kuauthorSüzer, Süleyman Tuncer
dc.contributor.kuauthorYaman, Onur
dc.contributor.schoolcollegeinstituteSCHOOL OF MEDICINE
dc.date.accessioned2024-11-09T12:40:01Z
dc.date.issued2017
dc.description.abstractBackground: This study compares the clinical and radiological results of three most commonly used dynamic stabilization systems in the field of orthopedic surgery. Methods: A total of 71 patients underwent single-level posterior transpedicular dynamic stabilization between 2011 and 2014 due to lumbar degenerative disc disease. Three different dynamic systems used include: (1) the Dynesys system; (2) a dynamic screw with a PEEK rod; and (3) a full dynamic system (a dynamic screw with a dynamic rod; BalanC). The mean patient age was 45.8 years. The mean follow-up was 29.7 months. Clinical and radiological data were obtained for each patient preoperatively and at 6, 12, and 24 months of follow-up. Results: Clinical outcomes were significantly improved in all patients. There were no significant differences in the radiological outcomes among the groups divided according to the system used. Screw loosening was detected in 2 patients, and 1 patient developed screw breakage. All patients with screw loosening or breakage underwent revision surgery. Conclusions: Each procedure offered satisfactory outcome regardless of which system was applied.
dc.description.fulltextYES
dc.description.indexedbyWOS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.issue3
dc.description.openaccessYES
dc.description.publisherscopeInternational
dc.description.sponsoredbyTubitakEuN/A
dc.description.sponsorshipN/A
dc.description.versionPublisher version
dc.description.volume9
dc.identifier.doi10.4055/cios.2017.9.3.310
dc.identifier.eissn2005-4408
dc.identifier.embargoNO
dc.identifier.filenameinventorynoIR01218
dc.identifier.issn2005-291X
dc.identifier.quartileQ2
dc.identifier.scopus2-s2.0-85027889343
dc.identifier.urihttps://hdl.handle.net/20.500.14288/2151
dc.identifier.wos411033200008
dc.keywordsDisc degeneration
dc.keywordsInstrumentation
dc.keywordsPedicle screw
dc.language.isoeng
dc.publisherKorean Orthopaedic Association
dc.relation.ispartofClinics in Orthopedic Surgery
dc.relation.urihttp://cdm21054.contentdm.oclc.org/cdm/ref/collection/IR/id/2517
dc.subjectMedicine
dc.subjectOrthopedics
dc.subjectNeurosurgery
dc.titleLumbar single-level dynamic stabilization with semi-rigid and full dynamic systems: a retrospective clinical and radiological analysis of 71 patients
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.kuauthorÖzer, Ali Fahir
local.contributor.kuauthorÖktenoğlu, Bekir Tunç
local.contributor.kuauthorEgemen, Emrah
local.contributor.kuauthorSasani, Mehdi
local.contributor.kuauthorYaman, Onur
local.contributor.kuauthorSüzer, Süleyman Tuncer
local.publication.orgunit1SCHOOL OF MEDICINE
local.publication.orgunit2School of Medicine
relation.isOrgUnitOfPublicationd02929e1-2a70-44f0-ae17-7819f587bedd
relation.isOrgUnitOfPublication.latestForDiscoveryd02929e1-2a70-44f0-ae17-7819f587bedd
relation.isParentOrgUnitOfPublication17f2dc8e-6e54-4fa8-b5e0-d6415123a93e
relation.isParentOrgUnitOfPublication.latestForDiscovery17f2dc8e-6e54-4fa8-b5e0-d6415123a93e

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
2517.pdf
Size:
292.82 KB
Format:
Adobe Portable Document Format