<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Publication:
Spastic ataxia composite (SPAXCOM): a scale to evaluate the progression of subjects with spasticity and ataxia

Loading...
Thumbnail Image

Departments

School / College / Institute

Item type:Organizational Unit,
SCHOOL OF MEDICINE
Upper Org Unit
Item type:Organizational Unit,

Program

Organization Authors

Co-Authors

Di Folco, Cecile

Dubec-Fleury, Charlotte

Traschuetz, Andreas

Kessler, Christoph

Reich, Selina

Gagnon, Cynthia

Lessard, Isabelle

Rodrigue, Xavier

Cocozza, Sirio

Satolli, Sara

Date

Language

Embargo Status

No

Journal Title

Journal ISSN

Volume Title

Alternative Title

Abstract

Background Current clinical scales that track disease progression are more tailored to spasticity or ataxia, with limited sensitivity to change.Objectives The aim was to develop a sensitive and valid scale specifically geared towards optimized sensitivity to change and adapted to patients presenting with both spasticity and ataxia.Methods Longitudinal data from 127 spastic paraplegia type 7 (SPG7) and 112 autosomal recessive spastic ataxia Charlevoix-Saguenay (ARSACS) patients were collected within the multicenter PROSPAX study. Sensitivity to change over 2 years of 30 items from the Scale for the Rating and Assessment of Ataxias (SARA), Spastic Paraplegia Rating Scale (SPRS), and the Activities of Daily Living subscale of the Friedreich's Ataxia Rating Scale (FARS-ADL) was evaluated. Items that demonstrated the highest sensitivity to change were used to build the Spastic Ataxia Composite scale (SPAXCOM).Results With seven items, the SPAXCOM showed an effect size of 0.71, higher than reference scales (SARA: 0.43, SPRS: 0.42, FARS-ADL: 0.27). The SPAXCOM had a similar sensitivity to change for both genotypes and was more sensitive in participants with a SARA lower than 10 and within the intermediate disease stage (FARS-Disease Staging: 2-3.5). The SPAXCOM showed a high correlation with disease duration (r = 0.67 [0.60; 0.72]) and disease stage (r = 0.86 [0.83; 0.89]). Perception of improvement, stagnation, and worsening were associated with a mean yearly SPAXCOM change of 0.44 (-0.14; 1.01), 0.61 (0.19; 1.03), and 1.22 (0.96; 1.49), respectively.Conclusion The SPAXCOM is more sensitive to change and homogeneous across genotypes than the reference scales, allowing a reduction of the required sample size in future clinical trials. (c) 2025 The Author(s). Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.

Source

Publisher

Wiley

Citation

item.page.haspartof

Source

Movement Disorders

item.page.ispartofseries

item.page.edition

DOI

10.1002/mds.70006

item.page.datauri

item.page.link

Rights

CC BY (Attribution)

Copyrights Note

Creative Commons license

Except where otherwise noted, this item's license is described as CC BY (Attribution)

Endorsement

Review

Supplemented By

Referenced By

Related Patent

Related Goal

Google Scholar
Scholar'da Ara ↗
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators