dc.description.abstractObjectives: It is known that the screws of the eight-plate hemiepiphysiodesis construct diverge as growth occurs through the physis. Our objective was to investigate whether there is a correlation between the amount of change of the joint orientation angle (JOA) and that of the interscrew angle (ISA) of the eight-plate hemiepiphysiodesis construct before and after correction. Patients and methods: After the institutional review board approval, medical charts and X-rays of all patients operated for either genu valgum or genu varum with eight-plate hemiepiphysiodesis were analyzed retrospectively. All consecutive patients at various ages with miscellaneous diagnoses were included. JOA and ISA were measured before and after correction. After review of the X-rays, statistical analyses were performed which included Pearson correlation coefficient and regression analyses. Results: There were 53 segments of 30 patients included in the study. Eighteen were males, and 12 were females. Mean age at surgery was 9.1 (range 3-17). Mean follow-up time was 21.5 (range, 7-46) months. The diagnoses were diverse. A strong correlation was found between the delta JOA (d-JOA) and delta ISA (d-ISA) of the eight-plate hemiepiphysiodesis construct (r = 0.759 (0.615-0.854, 95%CI), p < 0.001). This correlation was independent of the age and gender of the patient. Conclusions: There is a strong correlation between the d-ISA and the d-JOA. The d-ISA follows the d-JOA at a predictable amount through formulas which regression analysis yielded. This study confirms the clinical observation of the diverging angle between the screws is in correlation with the correction of the JOA. © 2016 Turkish Association of Orthopaedics and Traumatology.
dc.description.fulltextYES
dc.description.indexedbyWoS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.issue1
dc.description.openaccessYES
dc.description.publisherscopeNational
dc.description.sponsoredbyTubitakEuN/A
dc.description.sponsorshipN/A
dc.description.versionPublisher version
dc.description.volume51
dc.formatpdf
dc.identifier.doi10.1016/j.aott.2016.05.005
dc.identifier.embargoNO
dc.identifier.filenameinventorynoIR01192
dc.identifier.issn1017-995X
dc.identifier.linkhttps://doi.org/10.1016/j.aott.2016.05.005
dc.identifier.quartileQ4
dc.identifier.scopus2-s2.0-85013177992
dc.identifier.urihttps://hdl.handle.net/20.500.14288/85
dc.identifier.wos396620800008
dc.keywordsGenetics and molecular biology
dc.keywordsPharmacology, Toxicology and pharmaceutics
dc.keywordsChemistry
dc.keywordsChemical engineering
dc.keywordsCorrelation
dc.keywordsEight-plate
dc.keywordsHemiepiphysiodesis
dc.keywordsInterscrew angle
dc.keywordsJoint orientation angle
dc.keywordsScrew divergence
dc.languageEnglish
dc.publisherElsevier
dc.relation.urihttp://cdm21054.contentdm.oclc.org/cdm/ref/collection/IR/id/2258
dc.sourceActa Orthopaedica et Traumatologica Turcica
dc.subjectMedicine
dc.subjectBiochemistry
dc.titleIs there a correlation between the change in the interscrew angle of the eight-plate and the delta joint orientation angles?