Publication:
Transmission of methicillin-sensitive Staphylococcus aureus to a preterm infant through breast milk

dc.contributor.coauthorKayıran, Petek Genç
dc.contributor.coauthorKayıran, Sinan Mahir
dc.contributor.coauthorGürakan, Berkan
dc.contributor.departmentKUH (Koç University Hospital)
dc.contributor.departmentSchool of Medicine
dc.contributor.kuauthorCan, Füsun
dc.contributor.kuauthorErgönül, Önder
dc.contributor.schoolcollegeinstituteKUH (KOÇ UNIVERSITY HOSPITAL)
dc.contributor.schoolcollegeinstituteSCHOOL OF MEDICINE
dc.date.accessioned2024-11-09T23:04:18Z
dc.date.issued2014
dc.description.abstractContrary to traditional belief, breast milk is not a sterile fluid, even in healthy women. Breast milk may contain pathogenic bacteria that could cause serious infections especially in premature infants. There is no recommendation to evaluate breast milk routinely for pathogenic bacteria. However discontinuation of breastfeeding is not recommended even the mother had mastitis, because it is believed this will not pose a risk to infant. This is the report of a premature infant born at the 32nd gestational week who was readmitted to neonatal intensive care unit with late-onset Staphylococcus aureus sepsis. While searching for the transmission route of the infection, the breast milk was assessed. Although the mother did not have any symptoms of breast inflammation, S. aureus isolates, genetically 99% similar to those from the infant blood samples, were documented in the breast milk. Conclusion: Breast milk may contain pathogenic bacteria, even when expressed, stored and transported properly. When evaluating the source of a S. aureus infection in preterm infants, breast milk might be the source of the infection, even if the mother has no sign of mastitis.
dc.description.indexedbyWOS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.issue5
dc.description.openaccessNO
dc.description.publisherscopeInternational
dc.description.sponsoredbyTubitakEuN/A
dc.description.volume27
dc.identifier.doi10.3109/14767058.2013.819332
dc.identifier.eissn1476-4954
dc.identifier.issn1476-7058
dc.identifier.scopus2-s2.0-84894119176
dc.identifier.urihttps://doi.org/10.3109/14767058.2013.819332
dc.identifier.urihttps://hdl.handle.net/20.500.14288/8613
dc.identifier.wos332526200018
dc.keywordsBreast milk
dc.keywordsMethicillin-sensitive staphylococcus aureus
dc.keywordsNeonate
dc.keywordsPremature women
dc.language.isoeng
dc.publisherTaylor & Francis Ltd
dc.relation.ispartofJournal of Maternal-Fetal & Neonatal Medicine
dc.subjectObstetrics
dc.subjectGynecology
dc.titleTransmission of methicillin-sensitive Staphylococcus aureus to a preterm infant through breast milk
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.kuauthorCan, Füsun
local.contributor.kuauthorErgönül, Mehmet Önder
local.publication.orgunit1SCHOOL OF MEDICINE
local.publication.orgunit1KUH (KOÇ UNIVERSITY HOSPITAL)
local.publication.orgunit2KUH (Koç University Hospital)
local.publication.orgunit2School of Medicine
relation.isOrgUnitOfPublicationf91d21f0-6b13-46ce-939a-db68e4c8d2ab
relation.isOrgUnitOfPublicationd02929e1-2a70-44f0-ae17-7819f587bedd
relation.isOrgUnitOfPublication.latestForDiscoveryf91d21f0-6b13-46ce-939a-db68e4c8d2ab
relation.isParentOrgUnitOfPublication055775c9-9efe-43ec-814f-f6d771fa6dee
relation.isParentOrgUnitOfPublication17f2dc8e-6e54-4fa8-b5e0-d6415123a93e
relation.isParentOrgUnitOfPublication.latestForDiscovery055775c9-9efe-43ec-814f-f6d771fa6dee

Files