Publication:
Corneal tissue welding of clear corneal cut with infrared laser irradiation at different wavelengths

dc.contributor.coauthorRasier, Rifat
dc.contributor.coauthorOzeren, Mediha
dc.contributor.coauthorArtunay, Ozgur
dc.contributor.coauthorBahcecioglu, Halil
dc.contributor.coauthorSeckin, Ismail
dc.contributor.coauthorKurt, Adnan
dc.contributor.coauthorGulsoy, Murat
dc.contributor.departmentDepartment of Physics
dc.contributor.departmentN/A
dc.contributor.kuauthorSennaroğlu, Alphan
dc.contributor.kuauthorKalaycıoğlu, Hamit
dc.contributor.kuprofileFaculty Member
dc.contributor.kuprofilePhD Student
dc.contributor.otherDepartment of Physics
dc.contributor.schoolcollegeinstituteCollege of Sciences
dc.contributor.schoolcollegeinstituteGraduate School of Sciences and Engineering
dc.contributor.yokid23851
dc.contributor.yokidN/A
dc.date.accessioned2024-11-09T23:37:31Z
dc.date.issued2009
dc.description.abstractPurpose: The aim of the study is to investigate the potential of infrared lasers for cornea welding in order to seal corneal cuts done during cataract surgery Method: Clear corneal cuts were laser (1070-nm) and Tm: YAP laser (1980-nm) were applied on full thickness corneal tissue of freshly enucleated 40 bovine eyes. Optimal laser power, wavelength and exposure time parameters for immediate closure with minimal thermal damage was estimated through histological examination of welded samples with hematoxylin-eosin staining. Ten corneas with 1070-nm and ten corneas with 1980-nm wavelengths were compared with best paremeters. Results: Full thickness welding results to sample sizes were the following: 2 out of 7 with 809-nm diode laser; 2 out of 7 with 980-nm diode laser; 2 out of 3 with 1070-nm YLF; and 4 out of 6 with 1980-nm Tm: YAP laser. According to histologic examination 1070-nm and 1980-nm wavelengths which results had less carbonization and less change in substantia cornea compard; 5 out of 10 corneas were full thickness welded with 1070-nm and 4 out of 10 corneas were partial welded with 1980-nm. Discussion: Our study suggested that 809-nm diode laser welding in association with the topical application of ICG is a valid method for the closure of corneal tissues but 908-nm, 1070-nm diode laser and 1980-nm Tm: YAP laser welding without topical application of any chromophores are other promising options and have a great potential for corneal laser welding.
dc.description.indexedbyWoS
dc.description.issue5
dc.description.openaccessNO
dc.description.publisherscopeNational
dc.description.sponsoredbyTubitakEuN/A
dc.description.volume39
dc.identifier.doiN/A
dc.identifier.eissn2147-2661
dc.identifier.issn1300-0659
dc.identifier.quartileQ4
dc.identifier.uriN/A
dc.identifier.urihttps://hdl.handle.net/20.500.14288/12844
dc.identifier.wos219175200002
dc.keywords809-nm diode laser
dc.keywords980-nm diode laser
dc.keywords1070-nm YLF laser
dc.keywords1980-nm TM: YAP laser
dc.keywordsLaser tissue welding
dc.languageTurkish
dc.publisherTurkish Ophthalmological Society
dc.sourceTürk Oftalmoloji Dergisi-Turkish Journal of Ophthalmology
dc.subjectOphthalmology
dc.titleCorneal tissue welding of clear corneal cut with infrared laser irradiation at different wavelengths
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.authorid0000-0003-4391-0189
local.contributor.authorid0000-0002-7173-5907
local.contributor.kuauthorSennaroğlu, Alphan
local.contributor.kuauthorKalaycıoğlu, Hamit
relation.isOrgUnitOfPublicationc43d21f0-ae67-4f18-a338-bcaedd4b72a4
relation.isOrgUnitOfPublication.latestForDiscoveryc43d21f0-ae67-4f18-a338-bcaedd4b72a4

Files