Publication:
Improved drowsiness detection in drivers through optimum pairing of EEG features using an optimal EEG channel comparable to a multichannel EEG system

Thumbnail Image

School / College / Institute

Organizational Unit
Organizational Unit
SCHOOL OF MEDICINE
Upper Org Unit
Organizational Unit
GRADUATE SCHOOL OF HEALTH SCIENCES
Upper Org Unit

Program

KU Authors

Co-Authors

Minhas, Riaz
Peker, Nur Yasin
Hakkoz, Mustafa Abdullah
Arbatli, Semih
Celik, Yeliz
Erdem, Cigdem Eroglu
Peker, Yuksel
Semiz, Beren

Publication Date

Language

Embargo Status

No

Journal Title

Journal ISSN

Volume Title

Alternative Title

Abstract

Multichannel electroencephalography (EEG)-based drowsiness detection (DD) offers higher coverage but comes with increased computational demands, hardware requirements, and user discomfort, whereas single-channel devices are cost-effective and user-friendly but provide lower coverage. We hypothesized that an optimal channel with optimum paired EEG features could achieve coverage comparable to a multichannel system. Subject-specific, EEG-feature-specific thresholding techniques were introduced to classify 927 EEG epochs, derived from visual-based scoring through image processing of fifty drivers' facial expressions during a 50-min driving simulation, using six individual EEG channels with paired features. Ten normalized EEG features were extracted per epoch using discrete wavelet transform (DWT), and seven thresholding techniques were applied to identify the most consistent method across subjects. Epochs were classified as drowsy or wakeful based on whether their normalized values exceeded or fell below a specific threshold. We then assessed the coverage of each channel by comparing EEG patterns with visual-based scoring. To determine the optimal feature pair for classifying each epoch in alignment with visual-based scoring, 45 feature combinations were evaluated. The pairing of power spectral density (PSD) alpha and PSD theta in channels Frontal4 (F4) and Occipital2 (O2) yielded the highest coverage, achieving 96.1% and 95% with corresponding accuracies of 95.4% and 94.7%, respectively. These results slightly surpassed the coverage achieved using six channels with a single feature, with increases of 1.47% for F4 and 0.32% for O2. Our study demonstrates that an optimal EEG channel with optimum paired EEG features can reduce channels from six to one, lowering computational demands for wearable DD devices.

Source

Publisher

Springer Heidelberg

Subject

Computer Science, Interdisciplinary Applications, Engineering, Biomedical, Mathematical & Computational Biology, Medical Informatics

Citation

Has Part

Source

Medical & biological engineering & computing

Book Series Title

Edition

DOI

10.1007/s11517-025-03375-1

item.page.datauri

Link

Rights

CC BY (Attribution)

Copyrights Note

Creative Commons license

Except where otherwised noted, this item's license is described as CC BY (Attribution)

Endorsement

Review

Supplemented By

Referenced By

0

Views

1

Downloads

View PlumX Details