Reliability of single-slice-based 2D CT texture analysis of renal masses: influence of intra- and interobserver manual segmentation variability on radiomic feature reproducibility

dc.contributor.coauthorKocak, Burak
dc.contributor.coauthorDurmaz, Emine Şebnem
dc.contributor.coauthorAteş, Ece
dc.contributor.coauthorKılıçkesmez, Özgür
dc.contributor.departmentN/A
dc.contributor.kuauthorKaya, Özlem Korkmaz
dc.contributor.kuprofileDoctor
dc.contributor.schoolcollegeinstituteN/A
dc.contributor.unitKoç University Hospital
dc.contributor.yokidN/A
dc.date.accessioned2024-11-09T22:56:14Z
dc.date.issued2019
dc.description.abstractOBJECTIVE. The objective of our study was to investigate the potential influence of intra- and interobserver manual segmentation variability on the reliability of single-slice-based 2D CT texture analysis of renal masses. MATERIALS and METHODS. For this retrospective study, 30 patients with clear cell renal cell carcinoma were included from a public database. For intra- and interobserver analyses, three radiologists with varying degrees of experience segmented the tumors from unenhanced CT and corticomedullary phase contrast-enhanced CT (CECT) in different sessions. Each radiologist was blind to the image slices selected by other radiologists and him- or herself in the previous session. A total of 744 texture features were extracted from original, filtered, and transformed images. The intraclass correlation coefficient was used for reliability analysis. RESULTS. In the intraobserver analysis, the rates of features with good to excellent reliability were 84.4-92.2% for unenhanced CT and 85.5-93.1% for CECT. Considering the mean rates of unenhanced CT and CECT, having high experience resulted in better reliability rates in terms of the intraobserver analysis. In the interobserver analysis, the rates were 76.7% for unenhanced CT and 84.9% for CECT. The gray-level cooccurrence matrix and first-order feature groups yielded higher good to excellent reliability rates on both unenhanced CT and CECT. Filtered and transformed images resulted in more features with good to excellent reliability than the original images did on both unenhanced CT and CECT. CONCLUSION. Single-slice-based 2D CT texture analysis of renal masses is sensitive to intra- and interobserver manual segmentation variability. Therefore, it may lead to nonreproducible results in radiomic analysis unless a reliability analysis is considered in the workflow.
dc.description.indexedbyWoS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.issue2
dc.description.openaccessNO
dc.description.publisherscopeInternational
dc.description.volume213
dc.identifier.doi10.2214/AJR.19.21212
dc.identifier.eissn1546-3141
dc.identifier.issn0361-803X
dc.identifier.quartileQ1
dc.identifier.scopus2-s2.0-85070180038
dc.identifier.urihttp://dx.doi.org/10.2214/AJR.19.21212
dc.identifier.urihttps://hdl.handle.net/20.500.14288/7344
dc.identifier.wos477908100029
dc.keywordsCT
dc.keywordsReliability
dc.keywordsRenal cell carcinoma
dc.keywordsSegmentation
dc.keywordsTexture analysis
dc.languageEnglish
dc.publisherAmer Roentgen Ray Soc
dc.sourceAmerican Journal of Roentgenology
dc.subjectRadiology
dc.subjectNuclear medicine
dc.subjectMedical imaging
dc.titleReliability of single-slice-based 2D CT texture analysis of renal masses: influence of intra- and interobserver manual segmentation variability on radiomic feature reproducibility
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.authorid0000-0003-4477-0739
local.contributor.kuauthorKaya, Özlem Korkmaz

Files