Publication:
Magnetic actuated moems resonant biosensor array

dc.contributor.departmentDepartment of Electrical and Electronics Engineering
dc.contributor.departmentN/A
dc.contributor.departmentDepartment of Chemical and Biological Engineering
dc.contributor.departmentN/A
dc.contributor.kuauthorÜrey, Hakan
dc.contributor.kuauthorTimurdoğan, Erman
dc.contributor.kuauthorKavaklı, İbrahim Halil
dc.contributor.kuauthorAlaca, Burhanettin Erdem
dc.contributor.kuauthorNargül, Sezin
dc.contributor.kuprofileFaculty Member
dc.contributor.kuprofileUndergraduate Student
dc.contributor.kuprofileFaculty Member
dc.contributor.kuprofileFaculty Member
dc.contributor.kuprofilePhD Student
dc.contributor.otherDepartment of Electrical and Electronics Engineering
dc.contributor.otherDepartment of Chemical and Biological Engineering
dc.contributor.schoolcollegeinstituteCollege of Engineering
dc.contributor.schoolcollegeinstituteCollege of Engineering
dc.contributor.schoolcollegeinstituteCollege of Engineering
dc.contributor.schoolcollegeinstituteCollege of Engineering
dc.contributor.schoolcollegeinstituteGraduate School of Sciences and Engineering
dc.contributor.yokid8579
dc.contributor.yokidN/A
dc.contributor.yokid40319
dc.contributor.yokid115108
dc.contributor.yokidN/A
dc.date.accessioned2024-11-09T23:51:34Z
dc.date.issued2010
dc.description.abstractA biosensor platform is utilized in liquid for detection of His protein. T-shaped thin film nickel cantilevers are actuated magnetically using self-oscillation principle and the sensing is based on embedded diffraction gratings on the cantilevers with interferometric sensitivity. Experiments are performed in a custom 1ml liquid chamber and 5.7ng/ml detection sensitivity is demonstrated. Method is label-free, robust and allows mu ltip lexing. It also doesn't require any electrical connections to the MEMS sensor chip. Therefore, it is suitable for real-time multi analyte screening using a disposable chip in a portable device.
dc.description.indexedbyScopus
dc.description.openaccessYES
dc.description.publisherscopeInternational
dc.identifier.doi10.1109/OMEMS.2010.5672211
dc.identifier.isbn9781-4244-8925-1
dc.identifier.linkhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-78751521507anddoi=10.1109%2fOMEMS.2010.5672211andpartnerID=40andmd5=13f277616f68d402d6d79b5e4a508d5a
dc.identifier.quartileN/A
dc.identifier.scopus2-s2.0-78751521507
dc.identifier.urihttp://dx.doi.org/10.1109/OMEMS.2010.5672211
dc.identifier.urihttps://hdl.handle.net/20.500.14288/14736
dc.keywordsBio-sensor platforms
dc.keywordsBiosensor arrays
dc.keywordsDetection sensitivity
dc.keywordsElectrical connection
dc.keywordsEmbedded diffraction grating
dc.keywordsLabel free
dc.keywordsLiquid chambers
dc.keywordsMEMS sensors
dc.keywordsMulti-analytes
dc.keywordsNickel cantilevers
dc.keywordsPortable device
dc.keywordsSelf-oscillations
dc.keywordsBiosensors
dc.keywordsElectric connectors
dc.keywordsLiquids
dc.keywordsNanocantilevers
dc.keywordsNanophotonics
dc.keywordsMOEMS
dc.languageEnglish
dc.publisherIEEE
dc.source2010 International Conference on Optical MEMS and Nanophotonics, Optical MEMS and Nanophotonics 2010
dc.subjectElectrical electronics engineering
dc.subjectChemical engineering
dc.subjectBiological engineering
dc.titleMagnetic actuated moems resonant biosensor array
dc.typeConference proceeding
dspace.entity.typePublication
local.contributor.authorid0000-0002-2031-7967
local.contributor.authoridN/A
local.contributor.authorid0000-0001-6624-3505
local.contributor.authorid0000-0001-5931-8134
local.contributor.authoridN/A
local.contributor.kuauthorÜrey, Hakan
local.contributor.kuauthorTimurdoğan, Erman
local.contributor.kuauthorKavaklı, İbrahim Halil
local.contributor.kuauthorAlaca, Burhanettin Erdem
local.contributor.kuauthorNargül, Sezin
relation.isOrgUnitOfPublication21598063-a7c5-420d-91ba-0cc9b2db0ea0
relation.isOrgUnitOfPublicationc747a256-6e0c-4969-b1bf-3b9f2f674289
relation.isOrgUnitOfPublication.latestForDiscovery21598063-a7c5-420d-91ba-0cc9b2db0ea0

Files