<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Publication:
Should iliac wing screws be included in long segment dynamic stabilization?

Loading...
Thumbnail Image

Departments

Item type:Organizational Unit,

School / College / Institute

Item type:Organizational Unit,
SCHOOL OF MEDICINE
Upper Org Unit

Program

Organization Authors

Co-Authors

Hekimoğlu, Mehdi

Çerezci, Önder

Başak, Ahmet T.

Date

Language

Embargo Status

No

Journal Title

Journal ISSN

Volume Title

Alternative Title

Abstract

Background In this article, clinical sAtışfaction and radiological results are discussed in a series of patients where the iliac wings participate in dynamic stabilization. Dynamic stabilization is an effective alternative surgical treatment method, especially in clinical pictures that go with pain due to minor instabilities. Practically the unique surgical instrument used in multilevel instabilities is the Dynesys system. The most important drawback of the Dynesys system is that the S1 screws become loose in time. In this article, our aim is to find solution to S1 insufficiency by extension of the system to the iliac wings. Methods Nineteen patients (eight females, 11 males) with a mean age of 54.16 were included in the study. Patients had multilevel (level 2 and above) instability, iliac wings were included in the stabilized segments, and Visual Analog Scale (VAS) and Oswestry Disability Index (ODI) were used for patient follow-up. Results First year results showed a significant improvement in VAS and ODI. Regarding the complications, infection developed in one patient, loosening in the proximal iliac wing in one patient, and both S1 and iliac proximals in one patient, but no clinical findings were encountered. Conclusion When more than two levels of dynamic systems are used in chronic instability, especially in the elderly patients, S1 screws are loosened. In these patients, if the iliac bones are also included in stabilization, this problem is solved successfully. However unfortunately, Dynesys system does not have a screw suitable for the iliac bones.

Source

Publisher

Cureus

Citation

item.page.haspartof

Source

Cureus Journal of Medical Science

item.page.ispartofseries

item.page.edition

DOI

10.7759/cureus.13543

item.page.datauri

item.page.link

Rights

CC BY (Attribution)

Copyrights Note

Creative Commons license

Except where otherwise noted, this item's license is described as CC BY (Attribution)

Endorsement

Review

Supplemented By

Referenced By

Related Patent

Related Goal

Google Scholar
Scholar'da Ara ↗
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators