Publication:  Two cantilever based sytem for viscosity and density monitoring
| dc.contributor.coauthor | Yaralıoğlu, Göksenin G. | |
| dc.contributor.department | Department of Electrical and Electronics Engineering | |
| dc.contributor.department | Graduate School of Sciences and Engineering | |
| dc.contributor.kuauthor | Çakmak, Onur | |
| dc.contributor.kuauthor | Ermek, Erhan | |
| dc.contributor.kuauthor | Kılınç, Necmettin | |
| dc.contributor.kuauthor | Ürey, Hakan | |
| dc.contributor.schoolcollegeinstitute | College of Engineering | |
| dc.contributor.schoolcollegeinstitute | College of Sciences | |
| dc.contributor.schoolcollegeinstitute | GRADUATE SCHOOL OF SCIENCES AND ENGINEERING | |
| dc.date.accessioned | 2024-11-09T23:34:50Z | |
| dc.date.issued | 2015 | |
| dc.description.abstract | Viscosity and density measurements in liquids in real-time is challenging. Previous MEMS based approaches use frequency sweeps for the purpose and those methods are slow and not real-time. We show that high precision viscosity and density measurements are possible using two cantilevers with different widths and by tracking their frequencies with a Phase-Locked-Loop in real-time. | |
| dc.description.indexedby | WOS | |
| dc.description.openaccess | NO | |
| dc.description.publisherscope | International | |
| dc.description.sponsoredbyTubitakEu | N/A | |
| dc.identifier.doi | 10.1109/OMN.2015.7288898 | |
| dc.identifier.eissn | N/A | |
| dc.identifier.isbn | 978-1-4673-6834-6 | |
| dc.identifier.issn | 2160-5033 | |
| dc.identifier.quartile | N/A | |
| dc.identifier.scopus | 2-s2.0-84958580574 | |
| dc.identifier.uri | https://doi.org/10.1109/OMN.2015.7288898 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14288/12422 | |
| dc.identifier.wos | 380513000077 | |
| dc.keywords | MEMS | |
| dc.keywords | Microcantilever sensor | |
| dc.keywords | Viscosity | |
| dc.keywords | Density | |
| dc.language.iso | eng | |
| dc.publisher | IEEE | |
| dc.relation.ispartof | 2015 International Conference on Optical Mems and Nanophotonics (OMN) | |
| dc.subject | Engineering | |
| dc.subject | Electrical electronic engineering | |
| dc.subject | Nanoscience | |
| dc.subject | Nanotechnology | |
| dc.subject | Optics | |
| dc.title | Two cantilever based sytem for viscosity and density monitoring | |
| dc.type | Meeting Abstract | |
| dspace.entity.type | Publication | |
| local.contributor.kuauthor | Çakmak, Onur | |
| local.contributor.kuauthor | Ermek, Erhan | |
| local.contributor.kuauthor | Kılınç, Necmettin | |
| local.contributor.kuauthor | Ürey, Hakan | |
| local.publication.orgunit1 | GRADUATE SCHOOL OF SCIENCES AND ENGINEERING | |
| local.publication.orgunit1 | College of Sciences | |
| local.publication.orgunit1 | College of Engineering | |
| local.publication.orgunit2 | Department of Electrical and Electronics Engineering | |
| local.publication.orgunit2 | Graduate School of Sciences and Engineering | |
| relation.isOrgUnitOfPublication | 21598063-a7c5-420d-91ba-0cc9b2db0ea0 | |
| relation.isOrgUnitOfPublication | 3fc31c89-e803-4eb1-af6b-6258bc42c3d8 | |
| relation.isOrgUnitOfPublication.latestForDiscovery | 21598063-a7c5-420d-91ba-0cc9b2db0ea0 | |
| relation.isParentOrgUnitOfPublication | 8e756b23-2d4a-4ce8-b1b3-62c794a8c164 | |
| relation.isParentOrgUnitOfPublication | af0395b0-7219-4165-a909-7016fa30932d | |
| relation.isParentOrgUnitOfPublication | 434c9663-2b11-4e66-9399-c863e2ebae43 | |
| relation.isParentOrgUnitOfPublication.latestForDiscovery | 8e756b23-2d4a-4ce8-b1b3-62c794a8c164 | 