Publication: An integrated and flexible ultrasonic device for continuous bladder volume monitoring
dc.contributor.coauthor | Akcoren, Dincay | |
dc.contributor.coauthor | Eminoglu, Burak | |
dc.contributor.department | Department of Mechanical Engineering | |
dc.contributor.department | Graduate School of Sciences and Engineering | |
dc.contributor.department | School of Medicine | |
dc.contributor.kuauthor | Ali, Mohsin | |
dc.contributor.kuauthor | Bardakçı, Emine | |
dc.contributor.kuauthor | Beker, Levent | |
dc.contributor.kuauthor | Kılıç, Rasim | |
dc.contributor.kuauthor | Köseoğlu, Ersin | |
dc.contributor.kuauthor | Tarcan, Tufan | |
dc.contributor.kuauthor | Temel, Özgür Deniz | |
dc.contributor.kuauthor | Toymus, Alp Timuçin | |
dc.contributor.kuauthor | Yener, Umut Can | |
dc.contributor.schoolcollegeinstitute | College of Engineering | |
dc.contributor.schoolcollegeinstitute | GRADUATE SCHOOL OF SCIENCES AND ENGINEERING | |
dc.contributor.schoolcollegeinstitute | SCHOOL OF MEDICINE | |
dc.date.accessioned | 2024-12-29T09:39:01Z | |
dc.date.issued | 2024 | |
dc.description.abstract | Bladder volume measurement is critical for early detection and management of lower urinary tract dysfunctions. Current gold standard is invasive, and alternative technologies either require trained personnel or do not offer medical grade information. Here, we report an integrated wearable ultrasonic bladder volume monitoring device for accurate and autonomous continuous monitoring of the bladder volume. The device incorporates flexible and air-backed ultrasonic transducers and miniaturized control electronics with wireless data transmission capability. We demonstrate the real-life application of the device on healthy volunteers with various bladder shapes and sizes with high accuracy. Apart from the lower urinary tract dysfunctions, the proposed technology could also be adapted for various wearable ultrasonic applications. © The Author(s) 2024. | |
dc.description.indexedby | Scopus | |
dc.description.indexedby | PubMed | |
dc.description.issue | 1 | |
dc.description.openaccess | All Open Access | |
dc.description.openaccess | Gold Open Access | |
dc.description.publisherscope | International | |
dc.description.sponsoredbyTubitakEu | TÜBİTAK | |
dc.description.sponsorship | Funding text 1: We thank Gokberk Toymus for discussions on lower urinary tract dysfunctions, Seckin Akinci and Fariborz Mirlou for the help with PCB design and fabrication, Mohammad Meraj Ghanbari for the help with the pulser, Prof. Dr. Hayrettin Koymen for discussions on ultrasonic transducers, Ecem Ezgi Ozkahraman for the help with in-vivo measurements and the feedback on the manuscript. A.T.T is supported by the Scientific and Technological Research Council of Turkey (TUBITAK) through the 2232 (grant no. 118C295) program. U.C.Y. is supported by TUBITAK through the 2210/A program. E.B. is supported by TUBITAK through the 2210/C program. L.B. acknowledges the European Research Council (2ND-CHANCE,\u00A0grant no. 101043119). We acknowledge Ko\u00E7 University Surface Science and Technology Center (KUYTAM) and Ko\u00E7 University Nanofabrication and Nanocharacterization Center (n2STAR) for access to the infrastructure. The opinions expressed in this publication are those of the authors. They do not purport to reflect the opinions or views of the ADI, its subsidiaries, or employees.; Funding text 2: We thank Gokberk Toymus for discussions on lower urinary tract dysfunctions, Seckin Akinci and Fariborz Mirlou for the help with PCB design and fabrication, Mohammad Meraj Ghanbari for the help with the pulser, Prof. Dr. Hayrettin Koymen for discussions on ultrasonic transducers, Ecem Ezgi Ozkahraman for the help with in-vivo measurements and the feedback on the manuscript. A.T.T is supported by the Scientific and Technological Research Council of Turkey (TUBITAK) through the 2232 (grant no. 118C295) program. U.C.Y. is supported by TUBITAK through the 2210/A program. E.B. is supported by TUBITAK through the 2210/C program. L.B. acknowledges the European Research Council (2ND-CHANCE, grant no. 101043119). We acknowledge Ko\u00E7 University Surface Science and Technology Center (KUYTAM) and Ko\u00E7 University Nanofabrication and Nanocharacterization Center (n2STAR) for access to the infrastructure. The opinions expressed in this publication are those of the authors. They do not purport to reflect the opinions or views of the ADI, its subsidiaries, or employees. | |
dc.description.volume | 15 | |
dc.identifier.doi | 10.1038/s41467-024-50397-8 | |
dc.identifier.eissn | 2041-1723 | |
dc.identifier.issn | 2041-1723 | |
dc.identifier.link | ||
dc.identifier.quartile | Q1 | |
dc.identifier.scopus | 2-s2.0-85201719026 | |
dc.identifier.uri | https://doi.org/10.1038/s41467-024-50397-8 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14288/22886 | |
dc.keywords | Adult | |
dc.keywords | Equipment design | |
dc.keywords | Female | |
dc.keywords | Healthy volunteers | |
dc.keywords | Humans | |
dc.keywords | Male | |
dc.keywords | Monitoring, physiologic | |
dc.keywords | Organ size | |
dc.keywords | Transducers | |
dc.keywords | Ultrasonography | |
dc.keywords | Urinary bladder | |
dc.keywords | Wearable electronic devices | |
dc.keywords | Wireless technology | |
dc.language.iso | eng | |
dc.publisher | Nature Research | |
dc.relation.grantno | ||
dc.relation.ispartof | Nature Communications | |
dc.rights | ||
dc.subject | Urinary retention | |
dc.subject | Echography | |
dc.subject | Bladder | |
dc.title | An integrated and flexible ultrasonic device for continuous bladder volume monitoring | |
dc.type | Journal Article | |
dc.type.other | ||
dspace.entity.type | Publication | |
local.contributor.kuauthor | Toymus, Alp Timuçin | |
local.contributor.kuauthor | Yener, Umut Can | |
local.contributor.kuauthor | Bardakçı, Emine | |
local.contributor.kuauthor | Temel, Özgür Deniz | |
local.contributor.kuauthor | Köseoğlu, Ersin | |
local.contributor.kuauthor | Ali, Mohsin | |
local.contributor.kuauthor | Kılıç, Rasim | |
local.contributor.kuauthor | Beker, Levent | |
local.contributor.kuauthor | Tarcan, Tufan | |
local.publication.orgunit1 | GRADUATE SCHOOL OF SCIENCES AND ENGINEERING | |
local.publication.orgunit1 | SCHOOL OF MEDICINE | |
local.publication.orgunit1 | College of Engineering | |
local.publication.orgunit2 | Department of Mechanical Engineering | |
local.publication.orgunit2 | School of Medicine | |
local.publication.orgunit2 | Graduate School of Sciences and Engineering | |
relation.isOrgUnitOfPublication | ba2836f3-206d-4724-918c-f598f0086a36 | |
relation.isOrgUnitOfPublication | 3fc31c89-e803-4eb1-af6b-6258bc42c3d8 | |
relation.isOrgUnitOfPublication | d02929e1-2a70-44f0-ae17-7819f587bedd | |
relation.isOrgUnitOfPublication.latestForDiscovery | ba2836f3-206d-4724-918c-f598f0086a36 | |
relation.isParentOrgUnitOfPublication | 8e756b23-2d4a-4ce8-b1b3-62c794a8c164 | |
relation.isParentOrgUnitOfPublication | 434c9663-2b11-4e66-9399-c863e2ebae43 | |
relation.isParentOrgUnitOfPublication | 17f2dc8e-6e54-4fa8-b5e0-d6415123a93e | |
relation.isParentOrgUnitOfPublication.latestForDiscovery | 8e756b23-2d4a-4ce8-b1b3-62c794a8c164 |
Files
Original bundle
1 - 1 of 1