<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Publication:
Reprogramming the tachycardia parameters with long-detection strategy in patients with pre-existing implantable cardioverter-defibrillator

Loading...
Thumbnail Image

Departments

Item type:Organizational Unit,

School / College / Institute

Item type:Organizational Unit,

Program

Organization Authors

Co-Authors

Bozyel, Serdar

Aktas, Mujdat

Guler, Tumer Erdem

Dervis, Emir

Argan, Onur

Celikyurt, Umut

Agir, Aysen

Vural, Ahmet

Date

Language

Embargo Status

N/A

Journal Title

Journal ISSN

Volume Title

Alternative Title

Abstract

Background: A long-detection interval (LDI) programming has been proved to reduce shock therapy in patients who underwent de novo implantable cardioverter defibrillator (ICD) implantation. We aimed to evaluate effectiveness and safety of this new strategy in old ICD recipients. Methods: We included 147 primary prevention patients with ischaemic and non-ischaemic aetiology. Conventional setting parameters (18 of 24 intervals to detect ventricular arrhythmias (VA’s)) were reprogrammed with LDI strategy (30 of 40 intervals to detect VA’s). One monitoring zone (between 360 and 330 ms) and two therapy zones were programmed, treating all rhythms of cycle length <330 ms that met the duration criterion of 30/40 intervals and were discriminated as ventricular tachycardia/ventricular fibrillation (VT/VF). The supraventricular tachycardia (SVT) discriminators were used in all patients. Results: At a median follow-up of 24 months, 12.9% (n = 19) of patients received shock therapies (± antitachycardia pacing (ATP)). Appropriate and inappropriate shocks occurred in 7.5 and 5.4% of patients during follow-up, respectively. Only one patient experienced an arrhythmic syncope during the follow-up period. There was no death related to LDI programming. The LDI programming helped to stop unnecessary in 10 patients (6.8%), who otherwise would have been treated in the conventional programming. Conclusions: LDI programming was found safe and effective. Hence, old ICD recipients will benefit from this strategy.

Source

Publisher

Taylor and Francis

Citation

item.page.haspartof

Source

Acta Cardiologica

item.page.ispartofseries

item.page.edition

DOI

10.1080/00015385.2018.1488664

item.page.datauri

item.page.link

Rights

N/A

Copyrights Note

Rights and licensing

N/A

Endorsement

Review

Supplemented By

Referenced By

Related Patent

Related Goal

Item type:Goal, Access status: Open Access ,
03 - Good Health and Well-being
Over the last 15 years, the number of childhood deaths has been cut in half. This proves that it is possible to win the fight against almost every disease. Still, we are spending an astonishing amount of money and resources on treating illnesses that are surprisingly easy to prevent. The new goal for worldwide Good Health promotes healthy lifestyles, preventive measures and modern, efficient healthcare for everyone.
Google Scholar
Scholar'da Ara ↗
1
Görüntülenme
0
İndirme
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators