Publication:
Poisson's ratio of PDMS thin films

dc.contributor.coauthorBayraktar, Halil
dc.contributor.departmentDepartment of Mechanical Engineering
dc.contributor.departmentGraduate School of Sciences and Engineering
dc.contributor.departmentKUYTAM (Koç University Surface Science and Technology Center)
dc.contributor.kuauthorAksoy, Bekir
dc.contributor.kuauthorAlaca, Burhanettin Erdem
dc.contributor.kuauthorDoğru, Sedat
dc.contributor.schoolcollegeinstituteCollege of Engineering
dc.contributor.schoolcollegeinstituteGRADUATE SCHOOL OF SCIENCES AND ENGINEERING
dc.contributor.schoolcollegeinstituteResearch Center
dc.date.accessioned2024-11-09T22:52:59Z
dc.date.issued2018
dc.description.abstractDespite the fact that a small uncertainty in PDMS Poisson's ratio leads to significant errors in traction force microscopy, there is a clear lack of data for PDMS films at the scale of 100 mu m, a relevant size scale frequently employed in cell mechanics studies. Equally important is the need for consideration of the viscoelastic nature of PDMS, as no mechanical property - including Poisson's ratio - can be taken as a time-independent constant. The foremost challenge for addressing these issues is the difficulty of carrying out stress relaxation tests on miniature PDMS samples accompanied by non-contact strain measurement with a very high spatiotemporal resolution. This study introduces such a stress relaxation platform incorporating i) the proper means for the application of necessary boundary conditions, ii) a high-precision in load measurement, and iii) a non-contact, local strain measurement technique based on single particle tracking. During stretching, images were recorded at a rate of 18 Hz with a 40 mu m spatial resolution. Microsphere-embedded PDMS films as thin as 125 and 155 mu m were prepared to study the Poisson's ratio by a local strain microscope. After tracing the displacement of microspheres by a single particle tracking method and using a strain mapping, Poisson's ratio for 155-mu m-thick PDMS was found to decrease from 0.483 +/- 0.034 to 0.473 +/- 0.040 over a period of 20 min. For 125-mu m-thick PDMS, this reduction took place from 0.482 +/- 0.041 to 0.468 +/- 0.038. Moreover, a non-monotonic reduction was observed in both cases. This negative correlation between Poisson's ratio and relaxation time was found to be statistically significant for both thicknesses with p < 0.001. The viscoelastic behavior was further characterized through the Burgers model. With a measurement field of 597 x 550 mu m(2), this study emphasizes the importance of the local investigation of mechanical properties. Furthermore, the dependence of transverse strain on a film thickness difference of 30 mu m was measured to determine the sensitivity of local strain tracking. The inherent high resolution of the proposed approach enables one to measure deformations more precisely and to observe the temporal evolution of the Poisson's ratio that has not been observed before. In addition to the high-precision determination of PDMS Poisson's ratio, this work also offers a promising pathway for the accurate and time dependent determination of the mechanical properties of other soft materials, where similar ambiguities exist regarding the mechanical behavior.
dc.description.indexedbyWOS
dc.description.indexedbyScopus
dc.description.openaccessNO
dc.description.publisherscopeInternational
dc.description.sponsoredbyTubitakEuN/A
dc.description.sponsorshipScientific and Technological Research Council of Turkey [116F397] Support by the Scientific and Technological Research Council of Turkey under Grant No. 116F397 is gratefully acknowledged.
dc.description.volume69
dc.identifier.doi10.1016/j.polymertesting.2018.05.044
dc.identifier.eissn1873-2348
dc.identifier.issn0142-9418
dc.identifier.quartileQ1
dc.identifier.scopus2-s2.0-85047816236
dc.identifier.urihttps://doi.org/10.1016/j.polymertesting.2018.05.044
dc.identifier.urihttps://hdl.handle.net/20.500.14288/7122
dc.identifier.wos442068000046
dc.keywordsMicrofluidic devices
dc.keywordsViscoelastic characterization
dc.keywordsInstrumented indentation
dc.keywordsPolydimethysiloxane
dc.keywordsCells
dc.keywordsPolymers
dc.keywordsForce
dc.keywordsAdhesion
dc.language.isoeng
dc.publisherElsevier Sci Ltd
dc.relation.ispartofPolymer Testing
dc.subjectMaterials science
dc.subjectCharacterization and testing
dc.subjectPolymer science
dc.titlePoisson's ratio of PDMS thin films
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.kuauthorDoğru, Sedat
local.contributor.kuauthorAksoy, Bekir
local.contributor.kuauthorAlaca, Burhanettin Erdem
local.publication.orgunit1GRADUATE SCHOOL OF SCIENCES AND ENGINEERING
local.publication.orgunit1College of Engineering
local.publication.orgunit1Research Center
local.publication.orgunit2Department of Mechanical Engineering
local.publication.orgunit2KUYTAM (Koç University Surface Science and Technology Center)
local.publication.orgunit2Graduate School of Sciences and Engineering
relation.isOrgUnitOfPublicationba2836f3-206d-4724-918c-f598f0086a36
relation.isOrgUnitOfPublication3fc31c89-e803-4eb1-af6b-6258bc42c3d8
relation.isOrgUnitOfPublicationd41f66ba-d7a4-4790-9f8f-a456c391209b
relation.isOrgUnitOfPublication.latestForDiscoveryba2836f3-206d-4724-918c-f598f0086a36
relation.isParentOrgUnitOfPublication8e756b23-2d4a-4ce8-b1b3-62c794a8c164
relation.isParentOrgUnitOfPublication434c9663-2b11-4e66-9399-c863e2ebae43
relation.isParentOrgUnitOfPublicationd437580f-9309-4ecb-864a-4af58309d287
relation.isParentOrgUnitOfPublication.latestForDiscovery8e756b23-2d4a-4ce8-b1b3-62c794a8c164

Files