Publication:
Strain-controlled bulge test

Placeholder

School / College / Institute

Organizational Unit

Program

KU Authors

Co-Authors

Akar, Orhan
Akın, Tayfun

Publication Date

Language

Embargo Status

Journal Title

Journal ISSN

Volume Title

Alternative Title

Abstract

A closed-loop approach is adopted to implement strain rate Control during the bulge test. Due to the difficulty of measuring strains directly, the technique is based oil the conversion of displacement measurement to the corresponding strains using the plane-strain formulation. The necessary temporal evolution of the midpoint displacement of a rectangular diaphragm is derived under the condition of constant Strain rate and is Imposed as a control criterion. The technique is demonstrated oil 500-nm-thick Au diaphragms by applying, strain rates ranging from 2 x 10(-6) to 2 x 10(-4) s(-1). By measures the corresponding yield strength values, a Strain rate sensitivity of 0.11 is obtained, which is close to what was previously reported oil similar specimens using the microbending test.

Source

Publisher

Cambridge University Press (CUP)

Subject

Materials science, multidisciplinary

Citation

Has Part

Source

Journal of Materials Research

Book Series Title

Edition

DOI

10.1557/JMR.2008.0395

item.page.datauri

Link

Rights

Copyrights Note

Endorsement

Review

Supplemented By

Referenced By

0

Views

0

Downloads

View PlumX Details