<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Publication:
A pilot randomized controlled study to determine the effect of real-time videos with smart glass on the performance of the cardiopulmonary resuscitation

Loading...
Thumbnail Image

Departments

Item type:Organizational Unit,

School / College / Institute

Item type:Organizational Unit,
SCHOOL OF NURSING
UPPER

Program

KU-Authors

Organization Authors

Co-Authors

Ozkaynak, Mustafa

Bowler, Fara

Ponicsan, Heather

Zhang, Zhan

Bai, Enze

Date

Language

Embargo Status

N/A

Journal Title

Journal ISSN

Volume Title

Alternative Title

Abstract

The aim of this study was to determine the effect of real-time videos with smart glasses on the performance of cardiopulmonary resuscitation performed by nursing students. In this randomized controlled pilot study, the students were randomly assigned to the smart glass group (n = 12) or control group (n = 8). Each student's cardiopulmonary resuscitation performance was evaluated by determining sequential steps in the American Heart Association algorithm they applied and the accuracy and time of each step. A higher number of participants correctly checked response breathing, requested a defibrillator, activated the emergency response team, and provided appropriate chest compressions and breaths in the smart glass group than the control group. There were significant differences between groups. Furthermore, more participants significantly corrected chest compression rate and depth and hand location, used a defibrillator, and sustained cardiopulmonary resuscitation until the emergency response team arrived in the smart glass group than in the control group. Additionally, a significantly shorter time was observed in the smart glass group than in the control group in all variables except time to activate the emergency response team (P < .05). Remote expert assistance with smart glass technology during cardiopulmonary resuscitation is promising. Smart glass led to a significantly better ABC (airway, breathing, circulation) approach, chest compression depth and rate, and hand position. Furthermore, remote expert assistance with smart glass has the potential to improve overall resuscitation performance because it enabled students to initiate resuscitation, use a defibrillator, and defibrillate patients earlier. Nurses may benefit from smart glass technology in real life to provide effective cardiopulmonary resuscitation. Copyright © 2024 Wolters Kluwer Health, Inc. All rights reserved.

Source

Publisher

Lippincott Williams and Wilkins

Subject

Citation

item.page.haspartof

Source

CIN - Computers Informatics Nursing

item.page.ispartofseries

item.page.edition

DOI

10.1097/CIN.0000000000001211

item.page.datauri

item.page.link

Rights

N/A

Copyrights Note

Rights and licensing

N/A

Endorsement

Review

Supplemented By

Referenced By

Related Patent

Related Goal

Google Scholar
Scholar'da Ara ↗
2
Görüntülenme
0
İndirme
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators