Publication:
Rheology and extrusion of medical-grade thermoplastic polyurethane

dc.contributor.coauthorLu, Guangyu
dc.contributor.coauthorKalyon, Dilhan M.
dc.contributor.departmentDepartment of Chemistry
dc.contributor.kuauthorYılgör, Emel
dc.contributor.kuauthorYılgör, İskender
dc.contributor.schoolcollegeinstituteCollege of Sciences
dc.date.accessioned2024-11-09T23:57:30Z
dc.date.issued2003
dc.description.abstractThe selection of operating conditions and geometry for the processing of thermoplastic polyurethane, TPU, is a complicated task. This complication arises from the relatively high melting temperature of the crystalline hard blocks and the oxidative and thermal degradation and crosslinking that occur at temperatures that are relatively close to the melting temperature of the TPU. This article documents the rheology, extrusion, and structure development of a medical-grade TPU. The medical application requires that the additives commonly utilized in the development of polymeric resins, i.e., stabilizers, antioxidants, and lubricants, should be minimized; the TPU of this study contains no additives. At temperatures 10-20°C lower than the melting temperature of the TPU, the morphology of the hard blocks continues to evolve to generate a reversible increase in elasticity and shear viscosity of the TPU with increasing time. At temperatures greater than the melting temperature, the TPU undergoes degradation and crosslinking reactions, which give rise to a permanent increase in the elasticity and the shear viscosity of the TPU. The ramifications of the degradation and crosslinking at temperatures greater than 200°C and morphology modification upon the continuing evolution of the hard blocks at temperatures less than 200°C on the rheology and processing were investigated.
dc.description.indexedbyScopus
dc.description.issue12
dc.description.openaccessYES
dc.description.publisherscopeInternational
dc.description.sponsoredbyTubitakEuN/A
dc.description.volume43
dc.identifier.doi10.1002/pen.10158
dc.identifier.issn0032-3888
dc.identifier.quartileQ2
dc.identifier.scopus2-s2.0-1542605294
dc.identifier.urihttps://doi.org/10.1002/pen.10158
dc.identifier.urihttps://hdl.handle.net/20.500.14288/15301
dc.keywordsAlcohols
dc.keywordsAntioxidants
dc.keywordsCrosslinking
dc.keywordsElasticity
dc.keywordsFourier transform infrared spectroscopy
dc.keywordsMelting
dc.keywordsMolecular weight
dc.keywordsPolyurethanes
dc.keywordsPyrolysis
dc.keywordsStress relaxation
dc.keywordsThermal effects
dc.keywordsMelting temperature
dc.keywordsThermoplastic polyurethane (TPU)
dc.keywordsThermoplastics
dc.language.isoeng
dc.publisherWiley
dc.relation.ispartofPolymer Engineering and Science
dc.subjectChemistry
dc.titleRheology and extrusion of medical-grade thermoplastic polyurethane
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.kuauthorYılgör, Emel
local.contributor.kuauthorYılgör, İskender
local.publication.orgunit1College of Sciences
local.publication.orgunit2Department of Chemistry
relation.isOrgUnitOfPublication035d8150-86c9-4107-af16-a6f0a4d538eb
relation.isOrgUnitOfPublication.latestForDiscovery035d8150-86c9-4107-af16-a6f0a4d538eb
relation.isParentOrgUnitOfPublicationaf0395b0-7219-4165-a909-7016fa30932d
relation.isParentOrgUnitOfPublication.latestForDiscoveryaf0395b0-7219-4165-a909-7016fa30932d

Files