<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Publication:
A realistic simulation environment for mri-based robust control of untethered magnetic robots with intra-operational imaging

Loading...
Thumbnail Image

Departments

Item type:Organizational Unit,
Item type:Organizational Unit,

School / College / Institute

Item type:Organizational Unit,
Item type:Organizational Unit,
SCHOOL OF MEDICINE
Upper Org Unit

Program

KU-Authors

Organization Authors

Co-Authors

Tiryaki, Mehmet Efe

Erin, Önder

Date

Language

Embargo Status

N/A

Journal Title

Journal ISSN

Volume Title

Alternative Title

Abstract

Dual-use of magnetic resonance imaging (MRI) devices for robot tracking and actuation has transformed them into potential medical robotics platforms for targeted therapies and minimally invasive surgeries. In this letter, we present the dynamic simulations of anMRI-based tracking and actuation scheme, which performs intra-operational imaging while controlling untethered magnetic robots. In our realistic rigid-body simulation, we show that the robot could be controlled with a 1D projection-based position feedback while performing intra-operational echo-planar imaging (EPI). From the simulations, we observe that the velocity estimation error is the main source of the controller instability for low MRI sequence frequencies. To minimize the velocity estimation errors, we constrain the controller gains according to maximum closed-loop rates achievable for different sequence durations. Using the constrained controller in simulations, we confirm that EPI imaging could be introduced to the sequence as an intra-operational imaging method. Although the intro-operational imaging increases the position estimation error to 2.0 mm for a simulated MRI-based position sensing with a 0.6 mm Gaussian noise, it does not cause controller instability up to 128 k-space lines.With the presented approach, continuous physiological images could be acquired during medical operations while a magnetic robot is actuated and tracked inside an MRI device.

Source

Publisher

IEEE-Inst Electrical Electronics Engineers Inc

Subject

Citation

item.page.haspartof

Source

IEEE Robotics and Automation Letters

item.page.ispartofseries

item.page.edition

DOI

10.1109/LRA.2020.3002213

item.page.datauri

item.page.link

Rights

N/A

Copyrights Note

Rights and licensing

N/A

Endorsement

Review

Supplemented By

Referenced By

Related Patent

Related Goal

Google Scholar
Scholar'da Ara ↗
5
Görüntülenme
0
İndirme
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators