Publication:
On saturated flow boiling heat transfer of deionized water/ferrofluid on structured surfaces with or without external magnetic field

dc.contributor.coauthorBenam, Behnam Parizad
dc.contributor.coauthorMohammadilooey, Mandana
dc.contributor.coauthorSadaghiani, Abdolali
dc.contributor.coauthorPark, Hyun Sun
dc.contributor.coauthorKosar, Ali
dc.contributor.departmentDepartment of Chemistry
dc.contributor.departmentGraduate School of Sciences and Engineering
dc.contributor.kuauthorAcar, Havva Funda Yağcı
dc.contributor.kuauthorÇakır, Ece
dc.contributor.schoolcollegeinstituteCollege of Sciences
dc.contributor.schoolcollegeinstituteGRADUATE SCHOOL OF SCIENCES AND ENGINEERING
dc.date.accessioned2025-03-06T20:58:41Z
dc.date.issued2025
dc.description.abstractFlow boiling is one of the most effective methods for achieving high heat dissipation rates. The manipulation of magnetic fluids (ferrofluid) is one of the popular approaches for heat transfer enhancement. This study aims to experimentally investigate the effect of magnetic nanoparticles on saturated flow boiling heat transfer (FBHT) on microstructured silicon surfaces. The FBHT performance was assessed in the absence and presence of an external magnetic field with bubble force analysis by considering a single bubble under flow boiling conditions. The experimental setup consisted of a rectangular minichannel with two heating blocks on the bottom and top sides. Two different structures, including square and circular cavities, were tested. SPIONs (superparamagnetic iron oxide nanoparticles) were employed as magnetic nanoparticles. Two different types of working fluid were utilized, including deionized water (DW) and ferrofluid (FF), which contained diluted SPIONs in water. Helmholtz coils were utilized to generate an external magnetic field. Visualization with a high-speed camera enabled the study of boiling heat transfer (BHT) and bubble dynamics characteristics along with parametric effects. Experimental tests were conducted under three conditions: tests with DW, tests with FF, and ferrofluid in the presence of a magnetic field (FF/MF). These tests were carried out at two mass fluxes (300 and 400 kg/m2s) and over a heat flux range of 26.28 - 142.8 W/cm2. Adding nanoparticles further enhanced heat transfer and resulted in an increase in heat transfer coefficient (HTC) by up to 21% (from 32 to 38.7 kW/m2K). Moreover, application of an external magnetic field to the ferrofluid resulted in a reduction in the bubble departure size and an increase in HTC on the top surface, especially at high heat fluxes. The maximum HTC enhancement in the presence of the magnetic field was 25% (from 31.7 to 39.7 kW/m2K). These findings demonstrate the potential benefits of the use of magnetic nanoparticles and external magnetic fields to enhance flow boiling heat transfer on microstructured surfaces.
dc.description.indexedbyWOS
dc.description.indexedbyScopus
dc.description.publisherscopeInternational
dc.description.sponsoredbyTubitakEuTÜBİTAK
dc.description.sponsorshipThis work was supported by TÜBİTAK (The Scientific and Technological Research Council of Turkey) Support Program for Scientific and Technological Research Projects grant number 119 N116, European Comission (Horizon Europe MSCA Staff Exchanges-Micro-FloTec project-101082384) and under the framework of an international cooperation program, and this work was partially supported by the National Research Foundation of Korea (NRF) grant funded by the South Korean government (MSIT) (Project No. 2019K2A91A06095833, No. RS-2022-00144494) .
dc.identifier.doi10.1016/j.ijheatmasstransfer.2024.126323
dc.identifier.eissn1879-2189
dc.identifier.grantnoTÜBİTAK (The Scientific and Technological Research Council of Turkey) Support Program for Scientific and Technological Research Projects [119 N116];European Comission (Horizon Europe MSCA Staff Exchanges-Micro-FloTec project) [101082384];National Research Foundation of Korea (NRF) - South Korean government (MSIT) [2019K2A91A06095833, RS-2022-00144494]
dc.identifier.issn0017-9310
dc.identifier.quartileQ1
dc.identifier.scopus2-s2.0-85206651302
dc.identifier.urihttps://doi.org/10.1016/j.ijheatmasstransfer.2024.126323
dc.identifier.urihttps://hdl.handle.net/20.500.14288/27533
dc.identifier.volume236
dc.identifier.wos1341462700001
dc.keywordsFlow boiling
dc.keywordsMagnetic nanofluid
dc.keywordsMagnetic field
dc.keywordsBoiling heat transfer
dc.keywordsStructured surfaces
dc.language.isoeng
dc.publisherPergamon-Elsevier Science Ltd
dc.relation.ispartofINTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
dc.subjectThermodynamics
dc.subjectEngineerings
dc.titleOn saturated flow boiling heat transfer of deionized water/ferrofluid on structured surfaces with or without external magnetic field
dc.typeJournal Article
dspace.entity.typePublication
local.publication.orgunit1College of Sciences
local.publication.orgunit1GRADUATE SCHOOL OF SCIENCES AND ENGINEERING
local.publication.orgunit2Department of Chemistry
local.publication.orgunit2Graduate School of Sciences and Engineering
relation.isOrgUnitOfPublication035d8150-86c9-4107-af16-a6f0a4d538eb
relation.isOrgUnitOfPublication3fc31c89-e803-4eb1-af6b-6258bc42c3d8
relation.isOrgUnitOfPublication.latestForDiscovery035d8150-86c9-4107-af16-a6f0a4d538eb
relation.isParentOrgUnitOfPublicationaf0395b0-7219-4165-a909-7016fa30932d
relation.isParentOrgUnitOfPublication434c9663-2b11-4e66-9399-c863e2ebae43
relation.isParentOrgUnitOfPublication.latestForDiscoveryaf0395b0-7219-4165-a909-7016fa30932d

Files