Publication:
Double isocenter optimization with HD-MLC linear accelerator to treat extended fields in patients with head and neck cancers

dc.contributor.coauthorKüçük, Ahmet
dc.contributor.coauthorTopkan, Erkan
dc.contributor.kuauthorSelek, Uğur
dc.contributor.kuauthorBölükbaşı, Yasemin
dc.contributor.kuauthorDurankuş, Nilüfer Kılıç
dc.contributor.kuauthorSezen, Duygu
dc.contributor.kuauthorSağlam, Yücel
dc.contributor.kuauthorAtasoy, Ali İhsan
dc.contributor.kuauthorKaraköse, Fatih
dc.contributor.kuauthorAlpan, Vildan
dc.contributor.kuauthorAkdemir, Eyüb Yaşar
dc.contributor.kuauthorŞenyürek, Şükran
dc.contributor.kuprofileFaculty Member
dc.contributor.kuprofileFaculty Member
dc.contributor.kuprofileFaculty Member
dc.contributor.kuprofileDoctor
dc.contributor.kuprofileDoctor
dc.contributor.schoolcollegeinstituteSchool of Medicine
dc.contributor.unitKoç University Hospital
dc.contributor.yokid27211
dc.contributor.yokid216814
dc.contributor.yokidN/A
dc.contributor.yokid170535
dc.contributor.yokidN/A
dc.contributor.yokidN/A
dc.contributor.yokidN/A
dc.contributor.yokidN/A
dc.contributor.yokidN/A
dc.contributor.yokidN/A
dc.date.accessioned2024-11-09T12:11:54Z
dc.date.issued2021
dc.description.abstractPurpose: for departments with a congested patient burden or with a limited number of eligible LINACs, we investigated whether LINACS dedicated for SRS-SBRT with limited field high-definition (HD) multi-leaf collimator (MLC) could help to carry this load, and utilized a double-isocenter (DI) optimization with a limited field size of HD-MLC to defeat the craniocaudal field size restriction to match treated plans in a wide-field MLC LINAC for head and neck cancer patients. Methods: fourteen patients with locally advanced head and neck cancers were included, previously treated with simultaneous integrated boost volumetric modulated arc treatment (VMAT) in 33 fractions of clinical target volumes (CTV) of 70Gy, 63Gy, and 57Gy, via single isocenter (SI) plans in Millennium MLC-120 of Varian Trilogy. The DI plans were generated on Pinnacle TPS to be delivered in HD 120 leaves MLC on Varian TrueBeam. The organs at risk (OAR) doses and the prescription volume parameters were compared. Results: DI plans in HD-MLC LINACs were successfully matching the previously treated plans for OAR and CTV constraints. The CI (1.18 versus 1.26; p=0.004) and HI (0.23 versus 0.29; p<0.001) were significantly improved with DI, while the MUs (1321.5 versus 800.3; p<0.001) and the treatment delivery times (6.1 versus 3.7 min; p<0.001) per fraction increased modestly with DI compared to SI, respectively. Conclusions: we revealed that DI optimization plans prepared for HD-MLC could effectively accomplish our goal dosimetrically in locoregionally advanced head and neck cases, despite a modest increase in the MU and treatment delivery times per fraction. This technique may provide an alternative in case of downtimes of standard MLC systems or a standalone treatment machine in case of high volumes requiring extended-field IMRT procedures, or possibly shorten the lengthy waiting times in facilities with limited SRS or SBRT patients.
dc.description.fulltextYES
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.issue4
dc.description.openaccessYES
dc.description.publisherscopeInternational
dc.description.sponsoredbyTubitakEuN/A
dc.description.sponsorshipN/A
dc.description.versionPublisher version
dc.description.volume26
dc.formatpdf
dc.identifier.embargoNO
dc.identifier.filenameinventorynoIR03215
dc.identifier.issn1107-0625
dc.identifier.linkhttps://jbuon.com/archive/26-4-1571.pdf
dc.identifier.quartileN/A
dc.identifier.scopus2-s2.0-85114465336
dc.identifier.urihttps://hdl.handle.net/20.500.14288/1114
dc.keywordsHD MLC
dc.keywordsHead and neck
dc.keywordsIMRT
dc.keywordsIsocenter
dc.keywordsVMAT
dc.languageEnglish
dc.publisherBakis Productions LTD
dc.relation.grantnoNA
dc.relation.urihttp://cdm21054.contentdm.oclc.org/cdm/ref/collection/IR/id/9977
dc.sourceJournal of B.U.O.N.: Official Journal of the Balkan Union of Oncology
dc.subjectRadiosurgery
dc.subjectGamma Knife
dc.subjectBetatrons
dc.titleDouble isocenter optimization with HD-MLC linear accelerator to treat extended fields in patients with head and neck cancers
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.authorid0000-0001-8087-3140
local.contributor.authorid0000-0002-3170-5826
local.contributor.authoridN/A
local.contributor.authorid0000-0002-4505-2280
local.contributor.authoridN/A
local.contributor.authoridN/A
local.contributor.authoridN/A
local.contributor.authoridN/A
local.contributor.authoridN/A
local.contributor.authoridN/A
local.contributor.kuauthorSelek, Uğur
local.contributor.kuauthorBölükbaşı, Yasemin
local.contributor.kuauthorDurankuş, Nilüfer Kılıç
local.contributor.kuauthorSezen, Duygu
local.contributor.kuauthorSağlam, Yücel
local.contributor.kuauthorAtasoy, Ali İhsan
local.contributor.kuauthorKaraköse, Fatih
local.contributor.kuauthorAlpan, Vildan
local.contributor.kuauthorAkdemir, Eyüb Yaşar
local.contributor.kuauthorŞenyürek, Şükran

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
9977.pdf
Size:
2.78 MB
Format:
Adobe Portable Document Format