Publication:
A novel lower bound for tip-apex distance

dc.contributor.departmentDepartment of Mechanical Engineering
dc.contributor.departmentGraduate School of Sciences and Engineering
dc.contributor.departmentKUH (Koç University Hospital)
dc.contributor.departmentMARC (Manufacturing and Automation Research Center)
dc.contributor.departmentSchool of Medicine
dc.contributor.kuauthorAslan, Lercan
dc.contributor.kuauthorDemirhan, Mehmet
dc.contributor.kuauthorLazoğlu, İsmail
dc.contributor.kuauthorSeyahi, Aksel
dc.contributor.kuauthorSubaşı, Ömer
dc.contributor.schoolcollegeinstituteCollege of Engineering
dc.contributor.schoolcollegeinstituteGRADUATE SCHOOL OF SCIENCES AND ENGINEERING
dc.contributor.schoolcollegeinstituteKUH (KOÇ UNIVERSITY HOSPITAL)
dc.contributor.schoolcollegeinstituteResearch Center
dc.contributor.schoolcollegeinstituteSCHOOL OF MEDICINE
dc.date.accessioned2024-11-10T00:05:08Z
dc.date.issued2022
dc.description.abstractPurpose: The cut-out of the cephalomedullary nail is among the most common post-surgery complications for intertrochanteric fractures. As a risk predictor, a tip-apex distance (TAD) below 25 mm, observed from orthogonal fluoroscopic views, is recommended in the literature. This study aims to demonstrate that TAD < 25 mm is a mathematically insufficient risk definition and to complement the TAD upper bound with an appropriate lower bound, with the introduction of a novel distance parameter, TADX, based on the orthogonal projection of the nail tip on the central femoral midline. Method: Through a mathematical simulation software, all the possible points that lie inside the AP and lateral views of the proximal femoral hemisphere are utilized to create a 3D grid that is sorted into geometrically safe and risk-bearing regions. Extending this methodology, TAD < 25 mm, 10 mm < TAD < 25 mm, and the ideal tip position volumes are simulated. Finally, intersection volumes are created by a combination of different candidate lower TADX bounds and TAD < 25 mm upper bound to determine satisfactory TADX limits. Results: Simulation of TAD-bound zones exposed that TAD is only a mathematically suitable parameter for defining the upper boundary but not the lower boundary for the optimal region. However, using a TADX lower limit creates a 3D volume that is much closer to the optimal tip region volumetrically and can still be as quickly calculated from 2D AP and lateral views. Conclusions: According to the mathematical simulations, the use of a TADX lower bound of 9 mm for small, 7.5 mm for medium, and 7 mm for large femoral heads in conjunction with a TAD upper bound of 25 mm is suggested.
dc.description.indexedbyWOS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.issue3
dc.description.openaccessNO
dc.description.publisherscopeInternational
dc.description.sponsoredbyTubitakEuN/A
dc.description.volume48
dc.identifier.doi10.1007/s00068-020-01514-x
dc.identifier.eissn1863-9941
dc.identifier.issn1863-9933
dc.identifier.scopus2-s2.0-85092306822
dc.identifier.urihttps://doi.org/10.1007/s00068-020-01514-x
dc.identifier.urihttps://hdl.handle.net/20.500.14288/16376
dc.identifier.wos578569000001
dc.keywordsTip-apex distance
dc.keywordsTAD
dc.keywordsIntertrochanteric fracture
dc.keywordsProximal nailing
dc.keywordsFluoroscopy
dc.language.isoeng
dc.publisherSpringer Heidelberg
dc.relation.ispartofEuropean Journal of Trauma and Emergency Surgery
dc.subjectEmergency medicine
dc.titleA novel lower bound for tip-apex distance
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.kuauthorSubaşı, Ömer
local.contributor.kuauthorAslan, Lercan
local.contributor.kuauthorDemirhan, Mehmet
local.contributor.kuauthorSeyahi, Aksel
local.contributor.kuauthorLazoğlu, İsmail
local.publication.orgunit1GRADUATE SCHOOL OF SCIENCES AND ENGINEERING
local.publication.orgunit1SCHOOL OF MEDICINE
local.publication.orgunit1College of Engineering
local.publication.orgunit1Research Center
local.publication.orgunit1KUH (KOÇ UNIVERSITY HOSPITAL)
local.publication.orgunit2Department of Mechanical Engineering
local.publication.orgunit2MARC (Manufacturing and Automation Research Center)
local.publication.orgunit2KUH (Koç University Hospital)
local.publication.orgunit2School of Medicine
local.publication.orgunit2Graduate School of Sciences and Engineering
relation.isOrgUnitOfPublicationba2836f3-206d-4724-918c-f598f0086a36
relation.isOrgUnitOfPublication3fc31c89-e803-4eb1-af6b-6258bc42c3d8
relation.isOrgUnitOfPublicationf91d21f0-6b13-46ce-939a-db68e4c8d2ab
relation.isOrgUnitOfPublication52df3968-be7f-4c06-92e5-3b48e79ba93a
relation.isOrgUnitOfPublicationd02929e1-2a70-44f0-ae17-7819f587bedd
relation.isOrgUnitOfPublication.latestForDiscoveryba2836f3-206d-4724-918c-f598f0086a36
relation.isParentOrgUnitOfPublication8e756b23-2d4a-4ce8-b1b3-62c794a8c164
relation.isParentOrgUnitOfPublication434c9663-2b11-4e66-9399-c863e2ebae43
relation.isParentOrgUnitOfPublication055775c9-9efe-43ec-814f-f6d771fa6dee
relation.isParentOrgUnitOfPublicationd437580f-9309-4ecb-864a-4af58309d287
relation.isParentOrgUnitOfPublication17f2dc8e-6e54-4fa8-b5e0-d6415123a93e
relation.isParentOrgUnitOfPublication.latestForDiscovery8e756b23-2d4a-4ce8-b1b3-62c794a8c164

Files