<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Publication:
Anogenital distance in newborn infants conceived by assisted reproduction and natural conception

Loading...
Thumbnail Image

Departments

Item type:Organizational Unit,

School / College / Institute

Item type:Organizational Unit,
SCHOOL OF MEDICINE
Upper Org Unit

Program

Organization Authors

Co-Authors

Ercin, S.

Ertas, S.

Dundar, O.

Date

Language

Embargo Status

N/A

Journal Title

Journal ISSN

Volume Title

Alternative Title

Abstract

Research question: Does anogenital distance (AGD) differ in newborn infants conceived through assisted reproduction technology (ART) compared with those conceived naturally? Design: This case-control study looked at anthropometric and anogenital measurements in 247 male and 200 female newborns born after ART (n = 121) or natural conception (n = 326), within 24 h of birth. Anogenital measurements included distance from the centre of the anus to the anterior clitoris (AGDAC) and to the posterior fourchette (AGDAF) in female infants, and from the centre of the anus to the posterior base of the scrotum (AGDAS) and to the anterior base of the penis (AGDAP) in male infants. Results: ART mothers were older, more likely to be nulliparous and delivered by Caesarean section at an earlier gestational week. AGDAS of male infants was approximately twice the AGDAF of female infants (176 +/- 5.0 versus 9.1 +/- 3.6 mm). AGDAF in female infants conceived by ART compared with those conceived naturally was not significantly different (8.8 +/- 3.6 versus 9.3 +/- 3.6 mm; P = 0.404). AGDAC were also comparable for both groups (27.4 +/- 6.3 versus 27.7 +/- 71 mm; P = 0.770). In male infants, no significant difference was seen between ART and natural conception groups in terms of AGDAS (174 +/- 4.6 versus 177 +/- 5.2 mm, P = 0.742) and AGDAP (37.5 +/- 6.6 versus 38.0 +/- 6.7 mm, P = 0.589). When adjusted for gestational age, weight, length and head circumference, mode of conception was not associated with differences in any of the anogenital measurements. Conclusions: AGD measurements in infants conceived by ART are no different from those of infants conceived naturally.

Source

Publisher

Oxford Univ Press

Citation

item.page.haspartof

Source

Human Reproduction

item.page.ispartofseries

item.page.edition

DOI

10.1016/j.rbmo.2020.04.019

item.page.datauri

item.page.link

Rights

N/A

Copyrights Note

Rights and licensing

N/A

Endorsement

Review

Supplemented By

Referenced By

Related Patent

Related Goal

Google Scholar
Scholar'da Ara ↗
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators