Publication:
Anogenital distance in newborn infants conceived by assisted reproduction and natural conception

dc.contributor.coauthorErcin, S.
dc.contributor.coauthorErtas, S.
dc.contributor.coauthorDundar, O.
dc.contributor.departmentSchool of Medicine
dc.contributor.facultymemberYes
dc.contributor.kuauthorÖktem, Özgür
dc.contributor.kuauthorYakın, Kayhan
dc.contributor.schoolcollegeinstituteSCHOOL OF MEDICINE
dc.date.accessioned2024-11-09T22:59:04Z
dc.date.issued2020
dc.description.abstractResearch question: Does anogenital distance (AGD) differ in newborn infants conceived through assisted reproduction technology (ART) compared with those conceived naturally? Design: This case-control study looked at anthropometric and anogenital measurements in 247 male and 200 female newborns born after ART (n = 121) or natural conception (n = 326), within 24 h of birth. Anogenital measurements included distance from the centre of the anus to the anterior clitoris (AGDAC) and to the posterior fourchette (AGDAF) in female infants, and from the centre of the anus to the posterior base of the scrotum (AGDAS) and to the anterior base of the penis (AGDAP) in male infants. Results: ART mothers were older, more likely to be nulliparous and delivered by Caesarean section at an earlier gestational week. AGDAS of male infants was approximately twice the AGDAF of female infants (176 +/- 5.0 versus 9.1 +/- 3.6 mm). AGDAF in female infants conceived by ART compared with those conceived naturally was not significantly different (8.8 +/- 3.6 versus 9.3 +/- 3.6 mm; P = 0.404). AGDAC were also comparable for both groups (27.4 +/- 6.3 versus 27.7 +/- 71 mm; P = 0.770). In male infants, no significant difference was seen between ART and natural conception groups in terms of AGDAS (174 +/- 4.6 versus 177 +/- 5.2 mm, P = 0.742) and AGDAP (37.5 +/- 6.6 versus 38.0 +/- 6.7 mm, P = 0.589). When adjusted for gestational age, weight, length and head circumference, mode of conception was not associated with differences in any of the anogenital measurements. Conclusions: AGD measurements in infants conceived by ART are no different from those of infants conceived naturally.
dc.description.fulltextNo
dc.description.harvestedfromManual
dc.description.indexedbyWOS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.openaccessNO
dc.description.peerreviewstatusN/A
dc.description.publisherscopeInternational
dc.description.readpublishN/A
dc.description.sponsoredbyTubitakEuN/A
dc.description.studentonlypublicationNo
dc.description.studentpublicationNo
dc.description.versionN/A
dc.identifier.WoSQuartileQ1
dc.identifier.doi10.1016/j.rbmo.2020.04.019
dc.identifier.eissn1460-2350
dc.identifier.embargoN/A
dc.identifier.endpage482
dc.identifier.issn0268-1161
dc.identifier.issue3
dc.identifier.pubmed32576490
dc.identifier.scopus2-s2.0-85086735152
dc.identifier.startpage474
dc.identifier.urihttps://hdl.handle.net/20.500.14288/7833
dc.identifier.urihttps://doi.org/10.1016/j.rbmo.2020.04.019
dc.identifier.volume41
dc.identifier.wos000567448900018
dc.language.isoeng
dc.publisherOxford Univ Press
dc.relation.affiliationKoç University
dc.relation.collectionKoç University Institutional Repository
dc.relation.ispartofHuman Reproduction
dc.relation.openaccessN/A
dc.rightsN/A
dc.subjectObstetrics
dc.subjectGynecology
dc.subjectReproductive biology
dc.titleAnogenital distance in newborn infants conceived by assisted reproduction and natural conception
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.kuauthorÖktem, Özgür
local.contributor.kuauthorYakın, Kayhan
relation.isOrgUnitOfPublicationd02929e1-2a70-44f0-ae17-7819f587bedd
relation.isOrgUnitOfPublication.latestForDiscoveryd02929e1-2a70-44f0-ae17-7819f587bedd
relation.isParentOrgUnitOfPublication17f2dc8e-6e54-4fa8-b5e0-d6415123a93e
relation.isParentOrgUnitOfPublication.latestForDiscovery17f2dc8e-6e54-4fa8-b5e0-d6415123a93e

Files