Publication:
Need for standardization during cable tensioning: an in vitro experimental study on a femoral osteotomy model

dc.contributor.coauthorÖzgür KOYUNCU,ergün BOZDAĞ,Emin SÜNBÜLOĞLU
dc.contributor.departmentSchool of Medicine
dc.contributor.kuauthorBirsel, Olgar
dc.contributor.kuauthorEren, İlker
dc.contributor.kuauthorGünerbüyük, Caner
dc.contributor.kuauthorKılıçoğlu, Önder
dc.contributor.schoolcollegeinstituteSCHOOL OF MEDICINE
dc.date.accessioned2025-03-06T20:57:45Z
dc.date.issued2024
dc.description.abstractObjective: The ideal tension on a cable is affected by several factors, and the tensioning process is a relatively complex procedure. Individual variations can occur during tensioning, and the strain applied by residents at different training levels has not been previously questioned. For this purpose, we investigated the variations in the peak tensions applied by orthopedic residents, using a cable fixation model created on sheep femur. Methods: The experiment was conducted on the distal diaphysis of a 1-year-old sheep femur. A cobalt chrome cable, tensioned with a strain-meter integrated tensioner, was utilized to stabilize a prosthetic stem. The minimum tension required for a stable fixation under 8 N/m torque was recorded. Strain measurements of 120 trials of 12 residents were recorded and compared to their experience level and to the measured optimal tension. Results: The mean tension required for a stable fixation was 550 ± 45 N. The overall measured tension load was 540.3 ± 262.9 N. The mean tension provided by the 12 residents were between 175.7 ± 33.7 N and 875.5 ± 222.9 N. A significant difference was found between their highest and the lowest values (P < .0001). The level of experience was not correlated with the mean tension applied (P = .89) or with the difference of the minimum and the maximum tension (P = .81). The intraclass correlation coefficient was calculated as 0.1361 (95% CI, 0.02338-0.4242). Conclusion: Our results suggest that the residents’ decisions for the cable strain are not consistent or predictable, with high variations from the optimal value, regardless of their experience level.
dc.description.indexedbyTR Dizin
dc.description.publisherscopeNational
dc.description.sponsoredbyTubitakEuN/A
dc.identifier.doi10.5152/cjm.2024.23056
dc.identifier.eissn2687-1904
dc.identifier.issue2
dc.identifier.quartileN/A
dc.identifier.urihttps://doi.org/10.5152/cjm.2024.23056
dc.identifier.urihttps://hdl.handle.net/20.500.14288/27300
dc.identifier.volume47
dc.keywordsCable tensioning
dc.keywordsTorsional stability
dc.keywordsStrain measurement
dc.keywordsResident training
dc.language.isoeng
dc.publisherIUC University Press
dc.relation.ispartofCerrahpaşa Medical Journal
dc.subjectMedicine
dc.titleNeed for standardization during cable tensioning: an in vitro experimental study on a femoral osteotomy model
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.kuauthorBirsel, Olgar
local.contributor.kuauthorEren, İlker
local.contributor.kuauthorKılıçoğlu, Önder
local.contributor.kuauthorGünerbüyük, Caner
local.publication.orgunit1SCHOOL OF MEDICINE
local.publication.orgunit2School of Medicine
relation.isOrgUnitOfPublicationd02929e1-2a70-44f0-ae17-7819f587bedd
relation.isOrgUnitOfPublication.latestForDiscoveryd02929e1-2a70-44f0-ae17-7819f587bedd
relation.isParentOrgUnitOfPublication17f2dc8e-6e54-4fa8-b5e0-d6415123a93e
relation.isParentOrgUnitOfPublication.latestForDiscovery17f2dc8e-6e54-4fa8-b5e0-d6415123a93e

Files