Publication:
Effects of varying entry points and trendelenburg positioning degrees in internal jugular vein area measurements of newborns

dc.contributor.coauthorKaraaslan, P.
dc.contributor.coauthorÖrmeci, T.
dc.contributor.coauthorKarakaya, M. A.
dc.contributor.coauthorİnce, A.
dc.contributor.coauthorAslan, N. A.
dc.contributor.coauthorTaştekin, A.
dc.contributor.kuauthorDarçın, Kamil
dc.contributor.kuprofileTeaching Faculty
dc.contributor.unitKoç University Hospital
dc.date.accessioned2024-11-09T13:07:07Z
dc.date.issued2018
dc.description.abstractBackground: Recent guidelines from the National Institute for Clinical Excellence recommend the use of ultrasonography in the central venous catheterization of children. In this study, we aimed to compare area measurements using ultrasonography and efficiency of varying Trendelenburg degrees on the area measurements, for two different entry points used as internal jugular vein (IJV) cannulation points in newborns. Methods: Fifty-eight healthy newborns, weighing between 3000 and 3500 g, were recruited for this prospective study. Right IJV (RIJV) consecutive measurements were performed in three different Trendelenburg positions at 0 degrees, 15 degrees, and 30 degrees, at two different entry points: The superior approach and an inferior approach. The landmark used in the superior approach was the top of the triangle formed by the two heads of the sternocleidomastoid muscle with the clavicle; while in the inferior approach, it was taken as the midpoint of the clavicle, as measured from the upper edge of the clavicle. Results: The cross-sectional area (CSA) of the RIJV was significantly increased when using the inferior approach, compared to that in the superior approach, in all Trendelenburg degrees, including the neutral position. Both 15 degrees and 30 degrees Trendelenburg positioning resulted in a significant increase in CSA, both in superior and inferior approaches, when compared to neutral positioning. Conclusion: The use of 15 degrees Trendelenburg positioning may have significant advantage for increasing the CSA when used with the inferior approach.
dc.description.fulltextYES
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.issue4
dc.description.openaccessYES
dc.description.publisherscopeInternational
dc.description.sponsoredbyTubitakEuN/A
dc.description.sponsorshipN/A
dc.description.versionPublisher version
dc.description.volume21
dc.formatpdf
dc.identifier.doi10.4103/njcp.njcp_184_17
dc.identifier.eissn2229-7731
dc.identifier.embargoNO
dc.identifier.filenameinventorynoIR01431
dc.identifier.issn1119-3077
dc.identifier.linkhttps://doi.org/10.4103/njcp.njcp_184_17
dc.identifier.quartileN/A
dc.identifier.scopus2-s2.0-85045136849
dc.identifier.urihttps://hdl.handle.net/20.500.14288/2554
dc.keywordsInternal jugular vein area
dc.keywordsPreprocedural ultrasonography
dc.keywordsTrendelenburg positioning degrees
dc.languageEnglish
dc.publisherMedknow Publications
dc.relation.urihttp://cdm21054.contentdm.oclc.org/cdm/ref/collection/IR/id/8020
dc.sourceNigerian Journal of Clinical Practice
dc.subjectMedicine, general and internal
dc.titleEffects of varying entry points and trendelenburg positioning degrees in internal jugular vein area measurements of newborns
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.kuauthorDarçın, Kamil

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
8020.pdf
Size:
433.18 KB
Format:
Adobe Portable Document Format