Publication:
Effect of light backscattering from anterior segment structures on automated flare meter measurements

dc.contributor.coauthorYalınbaş, Duygu
dc.contributor.coauthorYılmaz, Mervenur
dc.contributor.coauthorZeynep
dc.contributor.coauthorHalim, Muhammad Sohail
dc.contributor.coauthorSepah, Yasir J.
dc.contributor.coauthorNguyen, Quan Dong
dc.contributor.departmentN/A
dc.contributor.kuauthorHasanreisoğlu, Murat
dc.contributor.kuauthorKesim, Cem
dc.contributor.kuauthorUzunay, Nur Sena
dc.contributor.kuauthorŞahin, Afsun
dc.contributor.kuprofileFaculty Member
dc.contributor.kuprofileTeaching Faculty
dc.contributor.kuprofileUndergraduated Student
dc.contributor.kuprofileFaculty Member
dc.contributor.researchcenterKoç University Research Center for Translational Medicine (KUTTAM) / Koç Üniversitesi Translasyonel Tıp Araştırma Merkezi (KUTTAM)
dc.contributor.schoolcollegeinstituteSchool of Medicine
dc.contributor.schoolcollegeinstituteSchool of Medicine
dc.contributor.schoolcollegeinstituteSchool of Medicine
dc.contributor.schoolcollegeinstituteSchool of Medicine
dc.contributor.yokid182001
dc.contributor.yokid387367
dc.contributor.yokidN/A
dc.contributor.yokid171267
dc.date.accessioned2024-11-09T23:57:28Z
dc.date.issued2022
dc.description.abstractBackground: To evaluate effect of maximal anterior cortical lens density, iris scatter and anterior chamber depth on laser flare photometry. Methods: Patients diagnosed with clinical uveitis were enrolled in the study. Clinical flare gradings were recorded upon the Standardization of Uveitis Nomenclature. Aqueous flare was measured with an automated device (Kowa FM700). Back-scattering from anterior cortical lens and anterior iris surface was calculated from Scheimpflug images. A curvilinear regression model was used to calculate estimated values for each clinical grade. These values were used to split cases in Group I (laser flare photometry lower than estimated) and Group II (laser flare photometry higher than estimated). Mean anterior chamber depth, pupil aperture, maximal anterior cortical lens density and iris scatter values were compared between two groups. A stepwise multiple regression analysis was performed to determine the effect of clinical flare gradings and ocular parameters on aqueous flare measurements. Results: The study included 228 eyes of 114 cases. Scheimpflug images were obtained from 105 eyes. Estimated aqueous flare measurements (in photons/milliseconds) were 4.87, 8.50, 14.81, 25.83, 45.04 and 136.93 for 0, 0.5+, 1+, 1.5+, 2+ and 3+ clinical flare respectively. Group II had higher maximal anterior cortical lens density than Group I (96.6 ± 37.1 vs 77.9 ± 17.1 pixel unit, p = 0.001). The measured aqueous flare was significantly related to clinical flare, maximal anterior cortical lens density and pupil aperture (adjusted R2: 0.480, p < 0.001). Conclusion: The back-scattered light from anterior cortical lens could affect laser flare photometry measurements. This effect might be quantified by Scheimpflug imaging.
dc.description.indexedbyWoS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.issue4
dc.description.openaccessNO
dc.description.publisherscopeInternational
dc.description.volume32
dc.identifier.doi10.1177/11206721211039350
dc.identifier.eissn1724-6016
dc.identifier.issn1120-6721
dc.identifier.quartileQ4
dc.identifier.scopus2-s2.0-85112438270
dc.identifier.urihttp://dx.doi.org/10.1177/11206721211039350
dc.identifier.urihttps://hdl.handle.net/20.500.14288/15294
dc.identifier.wos684648000001
dc.keywordsAnterior vhamber
dc.keywordsAqueous flare
dc.keywordsLaser flare photometer
dc.keywordsLens
dc.keywordsUveitis aqueous flare
dc.keywordsProtein-concentration
dc.keywordsCell meter
dc.languageEnglish
dc.publisherSage Publications Ltd
dc.sourceEuropean Journal of Ophthalmology
dc.subjectOphthalmology
dc.titleEffect of light backscattering from anterior segment structures on automated flare meter measurements
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.authorid0000-0001-9885-5653
local.contributor.authorid0000-0001-6747-1534
local.contributor.authorid0000-0001-6120-0995
local.contributor.authorid0000-0002-5083-5618
local.contributor.kuauthorHasanreisoğlu, Murat
local.contributor.kuauthorKesim, Cem
local.contributor.kuauthorUzunay, Nur Sena
local.contributor.kuauthorŞahin, Afsun

Files