Publication:
Measurement of red blood cell aggregation in disposable capillary tubes

dc.contributor.coauthorUyuklu, Mehmet
dc.contributor.coauthorÖzdem, Sebahat
dc.contributor.coauthorMeiselman, Herbert J.
dc.contributor.kuauthorBaşkurt, Oğuz Kerim
dc.contributor.kuprofileFaculty Member
dc.contributor.schoolcollegeinstituteSchool of Medicine
dc.contributor.yokidN/A
dc.date.accessioned2024-11-10T00:02:54Z
dc.date.issued2011
dc.description.abstractA new method is described in this paper that allows measurement of red blood cell (RBC) aggregation indexes in disposable glass tubes within minutes. Light transmission through the RBC suspension filled into a microhematocrit capillary at stasis is recorded during RBC aggregation; a novel method assures an initial dispersion of aggregates in the capillary. The resulting light transmittance-time data are analyzed to calculate various parameters. Measurement of erythrocyte sedimentation rate (ESR) and RBC aggregation using well established methods and the newly developed capillary tube aggregometer in blood samples with a wide range of RBC aggregation indicated significant correlations between these parameters. Additionally, light transmittance during complete disaggregation allows estimating hematocrit, thereby enabling hematocrit correction of the measured and calculated parameters. The newly developed capillary tube RBC aggregometer is suitable for use as a method to rapidly monitor disease activity and the acute phase response, especially at the point-of-care (e. g., health care facilities, physician's office) and for field studies.
dc.description.indexedbyWoS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.issue4
dc.description.openaccessNO
dc.description.publisherscopeInternational
dc.description.volume47
dc.identifier.doi10.3233/CH-2011-1411
dc.identifier.eissn1875-8622
dc.identifier.issn1386-0291
dc.identifier.quartileQ3
dc.identifier.scopus2-s2.0-79959225053
dc.identifier.urihttp://dx.doi.org/10.3233/CH-2011-1411
dc.identifier.urihttps://hdl.handle.net/20.500.14288/16232
dc.identifier.wos292265100007
dc.keywordsAcute phase response
dc.keywordsDisease activity
dc.keywordsErythrocyte sedimentation rate
dc.keywordsErythrocyte aggregation
dc.languageEnglish
dc.publisherIOS Press
dc.sourceClinical Hemorheology and Microcirculation
dc.subjectHematology
dc.subjectPeripheral vascular disease
dc.titleMeasurement of red blood cell aggregation in disposable capillary tubes
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.authoridN/A
local.contributor.kuauthorBaşkurt, Oğuz Kerim

Files