Publication:
Patient-relevant digital-motor outcomes for clinical trials in hereditary spastic paraplegia type 7: a multicenter PROSPAX study

Thumbnail Image

Organizational Units

Program

KU-Authors

Başak, Ayşe Nazlı

KU Authors

Co-Authors

Beichert L., Seemann J., Kessler C., Traschütz A., Müller D., Dillmann-Jehn K., Ricca I., Satolli S.,, Coarelli G., Timmann D., Gagnon C., van de Warrenburg B.P.C., Ilg W., Synofzik M., Schüle R., the PROSPAX Consortium

Advisor

Publication Date

Language

Journal Title

Journal ISSN

Volume Title

Abstract

Background and Objectives With targeted treatment trials on the horizon, identification of sensitive and valid outcome measures becomes a priority for andgt;100 spastic ataxias. While digital-motor measures, assessed using wearable sensors, are considered prime outcome candidates for spastic ataxias, genotype-specific validation studies are lacking. We here aimed to identify candidate digital-motor outcomes for spastic paraplegia type 7 (SPG7)-one of the most common spastic ataxias-that (1) reflect patient-relevant health aspects, even in mild, trial-relevant disease stages;(2) are suitable for a multicenter setting;and (3) assess mobility also during uninstructed walking simulating real life. Methods This cross-sectional multicenter study (7 centers, 6 countries) analyzed defined laboratory-based walking and uninstructed “supervised free walking” in patients with SPG7 and healthy controls using 3 wearable sensors (Opal APDM). For the extracted digital gait measures, we assessed effect sizes for the discrimination of patients and controls (Cliff δ) and Spearman correlations with measures of functional mobility and overall disease severity (Spastic Paraplegia Rating Scale [SPRS], including mobility subscore SPRSmobility;Scale for the Assessment and Rating of Ataxia [SARA]) and the activities of daily living subscore of the Friedreich Ataxia Rating Scale (FARS-ADL). Results Gait was analyzed in 65 patients with SPG7 and 50 healthy controls. Among 30 hypothesis-based gait measures, 18 demonstrated at least moderate effect size (δ andgt;0.5) in discriminating patients from controls and 17 even in mild disease stages (SPRSmobility ≤ 9, n = 41). Spatiotemporal variability measures such as spatial variability measure SPcmp (ρ = 0.67, p andlt;0.0001) and stride time CV (ρ = 0.67, p andlt;0.0001) showed the largest correlations with functional mobility (SPRSmobility)-as with overall disease severity (SPRS, SARA) and activities of daily living (FARS-ADL). The correlations of variability measures with SPRSmobility could be confirmed in mild disease stages (e.g., SPcmp: ρ = 0.50, p andlt;0.0001) and in “supervised free walking” (e.g., stride time CV: ρ = −0.57, p andlt;0.0001). Discussion We here identified trial-ready digital-motor candidate outcomes for the spastic ataxia SPG7 with proven multicenter applicability, ability to discriminate patients from controls, and correlation with measures of patient-relevant health aspects-even in mild disease stages. If validated longitudinally, these sensor outcomes might inform future natural history and treatment trials in SPG7 and other spastic ataxias.

Source:

Neurology

Publisher:

Lippincott Williams and Wilkins

Keywords:

Subject

Neurosciences

Citation

Endorsement

Review

Supplemented By

Referenced By

Copyrights Note

4

Views

4

Downloads

View PlumX Details