Research Outputs

Permanent URI for this communityhttps://hdl.handle.net/20.500.14288/2

Browse

Search Results

Now showing 1 - 10 of 2479
  • Placeholder
    Publication
    “Smart poisoning” of Co/SiO2 catalysts by sulfidation for chirality-selective synthesis of (9,8) single-walled carbon nanotubes
    (2016) Yuan, Yang; Karahan, H. Enis; Wei, Li; Zhai, Shengli; Lau, Raymond; Chen, Yuan; N/A; Yıldırım, Cansu; Birer, Özgür; Master Student; Researcher; Koç University Surface Science and Technology Center (KUYTAM) / Koç Üniversitesi Yüzey Teknolojileri Araştırmaları Merkezi (KUYTAM); N/A; N/A; N/A
    The chirality-selective synthesis of relatively large (diameter > 1 nm) single-walled carbon nanotubes (SWCNTs) is of great interest for a variety of practical applications, but only a few catalysts are available so far. Previous studies suggested that S (compounds) can enhance the chirality-selectivity of Co catalysts in SWCNT synthesis, however, the mechanism behind is not fully understood, and no tailorable methodology has yet been developed. Here, we demonstrate a facile approach to achieve the chirality-selective synthesis of SWCNTs by the sulfidation-based poisoning of silica-supported Co catalysts using a mixture of H2S and H2. The UV-vis-NIR, photoluminescence, and Raman spectroscopy results together show that the resulting SWCNTs have a narrow diameter distribution of around 1.2 nm, and (9,8) nanotubes have an abundance of ∼38% among the semiconducting species. More importantly, the carbon yield achieved by the sulfided catalyst (2.5 wt%) is similar to that of the nonsulfided one (2.7 wt%). The characterization of the catalysts by X-ray diffraction, X-ray photoelectron spectroscopy, X-ray fluorescence, and H2 temperature-programmed reduction shows that the sulfidation leads to the formation of Co9S8 nanoparticles. However, Co9S8 nanoparticles are reduced back to regenerate metallic Co nanoparticles during the synthesis of SWCNTs, which maintain a high carbon yield. In this process, Co9S8 nanoparticles seemingly intermediate the production of Co nanoparticles with narrow size distribution. Due to the fact that the poisoning step improves the quality of the end-product rather than hampering the growth process, we have coined the process developed as “smart poisoning”. This study not only reveals the mechanism behind the beneficial role of S in the selective synthesis of relatively large SWCNTs but also presents a promising method to create chirality-selective catalysts with high activity for scalable synthesis.
  • Placeholder
    Publication
    1200 nm pumped Tm3+:Lu2O3 ceramic lasers
    (Optical Soc Amer, 2018) Özharar, Sarper; N/A; Department of Physics; Toker, Işınsu Baylam; Sennaroğlu, Alphan; PhD Student; Faculty Member; Department of Physics; N/A; College of Sciences; N/A; 23851
    We report on an experimental demonstration of a 1200-nm pumped Tm3+:Lu2O3 ceramic laser. By using a gain-switched, tunable Cr4+:forsterite laser, the excitation spectrum was measured, with optimum pumping bands centered near 1198 nm, 1204 nm, and 1211 nm. The highest slope efficiency of 21.5% was obtained at the pump wavelength of 1204 nm. Comparative energy efficiency measurements performed near 1200-nm and 800-nm pumping further showed that nearly 40% improvement was obtained in slope efficiency measured with respect to the incident pump energy for 1200-nm pumping. A transition was further observed from single-wavelength operation at 2066 nm to dual-wavelength operation near 2066 nm and 1967 nm for absorbed pump energies above 50 mu J. In this regime, two consecutive output pulses were observed in the time domain. The shortest temporal duration of the first pulse was 1.1 mu s at the incident pulse energy of 105 mu J. The duration and build-up time of the second pulse remained around 5.9 mu s and 18.5 mu s. We believe that the improved energy efficiency demonstrated for the 1.5% Tm3+:Lu2O3 ceramic with 1200-nm pumping can be used as an alternative scheme for the excitation of Tm3+:Lu2O3 ceramic lasers.
  • Placeholder
    Publication
    18F-FDG PET/CT mean suv and metabolic tumor volume for mean survival time in non-small cell lung cancer
    (Lippincott Williams and Wilkins, 2015) Kurtipek, Ercan; Çaycı, Mustafa; Düzgün, Nuri; Esme, Hıdır; Terzi, Yüksel; Bakdık, Süleyman; Ünlü, Yaşar; Burnik, Cengiz; Bekçi, Taha Tahir; N/A; Aygün, Murat Serhat; Teaching Faculty; School of Medicine; Koç University Hospital; 291692
    Objective: The study was designed to determine the relationship between survival time of standardized uptake value (SUVmax and SUVmean) and metabolic tumor volume (MTV) in patients with non-small cell lung cancer (NSCLC), and examine the impact of demographic, clinical, and radiological data of these patients on survival. Materials and Methods: We performed a retrospective analysis of the records of 79 patients with NSCLC who presented to our hospital between May 2010 and March 2013, received a final diagnosis, and underwent 18F-FDG PET/CT for staging. Clinical, radiological, and 18F-FDG PET/CT parameters with an impact on prognosis such as the SUVmax of the primary tumor as calculated by the volumetric region of interest in the 18F-FDG PET/CT scans during initial diagnosis, mean SUV of the tumor, and MTV obtained with a threshold of SUVmax greater than 2.5 were recorded and statistically analyzed. A statistical analysis was carried out based on the clinical, radiological, and PET/CT findings of the patients who were divided into 2 groups: survivors and nonsurvivors. Results: Seventy patients (88.6%) were men, and 9 (11.4%) were women. The mean age was 63.65 ± 11.51 years in the nonsurvivor group (n = 40) versus 62.74 ± 10.60 years in the survivor group (n = 39) (Table 1). The mean survival time from diagnosis was 7.9 ± 6.52 months in the nonsurvivor group versus 14.09 ± 7.41 months in the survivor group. The mean survival time was 12.9 ± 7.9 months for those aged 60 or younger, whereas it was 9.9 ± 7.2 years for those aged 60 or older. According to the Cox regression analysis, higher MTV [relative risk (RR), 1.006; P = 0.03] and mean SUVmax (mSUV) (RR, 1.302; P = 0.03) had a significant impact on shortening of the mean survival time. However, no statistical significance was reached for SUVmax measurements (RR, 0.970; P = 0.39). Furthermore, there was a significant relationship between increased tumor size (andlt;2 cm, 2-4 cm, and ≥4 cm) and shortened mean survival time (P = 0.03). Conclusion: The present study showed that MTV and mSUV of FDG PET/CT scans of the tumor, but not SUVmax, had a significant impact on survival time of patients with NSCLC. Based on this result, we believe that we might have more accurate information about the survival time of our patients if we also evaluate mSUV and MTV in combination with mSUV, which is frequently used for diagnosis and monitoring of patients with NSCLC during our daily practice. © 2015 Wolters Kluwer Health, Inc. All rights reserved.
  • Placeholder
    Publication
    18F-FDG PET/CT texture analysis of anthracotic lymph nodes detected with EBUS and comparison with cytological findings
    (P.Ziti and Co, 2022) N/A; N/A; N/A; N/A; N/A; N/A; N/A; N/A; Çağlayan, Benan Niku; Fırat, Pınar Arıkan; Seymen, Hülya; Bulutay, Pınar; Falay, Fikri Okan; Demirtaş, Elif; Demirkol, Mehmet Onur; Meriçöz, Çisel Aydın; Faculty Member; Faculty Member; Teaching Faculty; Teaching Faculty; Teaching Faculty; Master Student; Faculty Member; Teaching Faculty; School of Medicine; School of Medicine; School of Medicine; School of Medicine; School of Medicine; Graduate School of Health Sciences; School of Medicine; School of Medicine; 230719; 207545; 350778; 133565; 246484; N/A; 196946; 162418
    Objective: Lymph node metastasis is the most important factor both in the selection of treatment since many alternatives have been created in recent years, and in the evaluation of prognosis in lung cancer. The most unpredictable cause of lymph node false positivity in fluorine-18-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) is anthracosis. The aim of this study is to compare 18F-FDG PET/CT texture information of anthracotic (ALN) and metastatic (MLN) lymph nodes, after re-evaluation of the cytological samples obtained from anthracotic lymph nodes by EBUS-TBNA. Subjects and Methods: Ninety nine patients, 78 of whom had primary lung cancer were included in the study. Two hundred and three lymph nodes from 99 patients sampled by EBUS-TBNA and diagnosed cytologically as ALN or MLN were evaluated retrospectively. All ALN were classified as grades 1, 2 and 3 cytologically. Volume of interest (VOI) of 203 lymph nodes was re-drawn and maximum standardized uptake value (SUVmax), metabolic tumor volume (MTV) and total lesion glycolysis (TLG) values were recorded. Results: There was a statistically significant difference in MTV and TLG values in MLN and all ALN grades. However, only grade 1-2 ALNs could be differentiated from MLNs with SUVmax, and no statistically significant difference was found in grade 3 ALN and MLN. Metabolic tumor volume and TLG values over 4.10cm3 and 26.57 showed 60% and 59% sensitivity and 83% and 94 specificity respectively for the identification of MLN. Conclusion: The contribution of MTV and TLG values of 18F-FDG PET/CT to the differential diagnosis of ALN is much more valuable than SUVmax values, especially for grade 3 anthracosis. It was thought that cytological reporting of only grade 3 ALN could make a better contribution to the 18F-FDG PET/CT evaluation analysis.
  • Placeholder
    Publication
    2.3-μm Tm3+: YLF laser passively Q-switched with a Cr2+: ZnSe saturable absorber
    (Optical Soc Amer, 2017) N/A; N/A; Canbaz, Ferda; Yorulmaz, İsmail; Sennaroğlu, Alphan; PhD Student; PhD Student; Faculty Member; Koç University Surface Science and Technology Center (KUYTAM) / Koç Üniversitesi Yüzey Teknolojileri Araştırmaları Merkezi (KUYTAM); Graduate School of Sciences and Engineering; Graduate School of Sciences and Engineering; College of Sciences; N/A; N/A; 23851
    We report, what is to our knowledge, the first passively Q-switched operation of a 2.3-mu m Tm3+ : YLF laser by using a Cr2+ : ZnSe saturable absorber. In the experiments, a tunable Ti3+ : sapphire laser was used to end pump the Tm3+ : YLF gain medium inside an x cavity. A Cr2+ : ZnSe saturable absorber was also included in the cavity to initiate passive Q switching. At all pump power levels above lasing threshold, passively Q-switched operation of the Tm3+ : YLF laser could be obtained at 2309 nm with pulse durations and repetition frequencies in the ranges of 1.21.4 mu s and 0.3-2.1 kHz, respectively. Analysis of power dependent repetition rate data further gave an estimated value of 3.1% for the round-trip saturable loss of the Cr2+ : ZnSe saturable absorber.
  • Placeholder
    Publication
    21 fs Cr:LiSAF laser mode locked with a single-walled carbon nanotube saturable absorber
    (Optical Soc Amer, 2019) Bae, Ji Eun; Rotermund, Fabian; Demirbaş, Ümit; N/A; N/A; N/A; Department of Physics; Tanısalı, Gökhan; Toker, Işınsu Baylam; Taşçı, Mısra; Sennaroğlu, Alphan; PhD Student; PhD Student; Undergraduate Student; Faculty Member; Department of Physics; Koç University Surface Science and Technology Center (KUYTAM) / Koç Üniversitesi Yüzey Teknolojileri Araştırmaları Merkezi (KUYTAM); Graduate School of Sciences and Engineering; Graduate School of Sciences and Engineering; School of Medicine; College of Sciences; N/A; N/A; N/A; 23851
    We report the shortest femtosecond pulses directly generated from a solid-state laser that is mode locked by using a single-walled carbon nanotube saturable absorber (SWCNT-SA). In the experiments, we used a 660 nm diode-pumped, low-threshold extended-cavity Cr:LiSAF laser operating around 850 nm with a repetition rate of 47.9 MHz. The SWCNT-SA mode-locked Cr:LiSAF laser produced 21 fs pulses with a time-bandwidth product of 0.56 by using only 210 mW of pump power. Pump-probe spectroscopy measurements showed that the SWCNT-SA exhibited saturable absorption with slow and fast decay times of 2.7 ps and 0.4 ps. The single-pass modulation depth and saturation fluence of the SWCNT-SA were further determined as 0.3% and 45 mu J/cm(2) at the pump wavelength of 850 nm.
  • Placeholder
    Publication
    3D printed poly(lactic acid) scaffolds modified with chitosan and hydroxyapatite for bone repair applications
    (Elsevier, 2020) N/A; N/A; N/A; N/A; Department of Chemistry; Department of Chemical and Biological Engineering; Department of Chemistry; Nazeer, Muhammad Anwaar; Önder, Özgün Can; Sevgili, İlkem; Yılgör, Emel; Kavaklı, İbrahim Halil; Yılgör, İskender; PhD Student; PhD Student; PhD Student; Researcher; Faculty Member; Faculty Member; Department of Chemical and Biological Engineering; Department of Chemistry; Koç University Surface Science and Technology Center (KUYTAM) / Koç Üniversitesi Yüzey Teknolojileri Araştırmaları Merkezi (KUYTAM); Graduate School of Sciences and Engineering; Graduate School of Sciences and Engineering; Graduate School of Sciences and Engineering; College of Sciences; College of Engineering; College of Sciences; N/A; N/A; N/A; N/A; 40319; 24181
    3D printed poly(lactic acid) (PLA) scaffolds surface modified with chitosan (CS) and hydroxyapatite (HA) to produce a novel bioactive composite scaffold is reported. Excellent mechanical properties of PLA, the bioactivity of CS, and osteogenic characteristics of HA are combined to fabricate composite scaffolds using a simple desktop 3D printer. Scaffolds were characterized through attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy, scanning electron microscopy (SEM), energy dispersive X-ray (EDX) spectroscopy, X-ray diffraction (XRD) and water contact angle measurements before and after modification. Formic acid was used as a solvent to prepare stable CS/HA dispersions and was found to be a suitable solvent for producing PLA/CS/HA composites. Surface properties of modified scaffolds were superior in terms of hydrophilicity and bioactivity, which resulted in enhanced attachment and proliferation of human osteosarcoma cells in vitro compared to the unmodified PLA scaffolds.
  • Placeholder
    Publication
    3D printing of cytocompatible gelatin-cellulose-alginate blend hydrogels
    (Wiley-V C H Verlag Gmbh, 2020) Erkoc, Pelin; Uvak, Ileyna; Odeh, Yazan Nitham; Akdogan, Ozan; Odeh, Yazan Nitham; Akdogan, Ozan; N/A; Department of Chemistry; Department of Chemical and Biological Engineering; Nazeer, Muhammad Anwaar; Batool, Syeda Rubab; Kızılel, Seda; PhD Student; Researcher; Faculty Member; Department of Chemistry; Department of Chemical and Biological Engineering; Graduate School of Sciences and Engineering; College of Sciences; College of Engineering; N/A; N/A; 28376
    3D bioprinting of hydrogels has gained great attention due to its potential to manufacture intricate and customized scaffolds that provide favored conditions for cell proliferation. Nevertheless, plain natural hydrogels can be easily disintegrated, and their mechanical strengths are usually insufficient for printing process. Hence, composite hydrogels are developed for 3D printing. This study aims to develop a hydrogel ink for extrusion-based 3D printing which is entirely composed of natural polymers, gelatin, alginate, and cellulose. Physicochemical interactions between the components of the intertwined gelatin-cellulose-alginate network are studied via altering copolymer ratios. The structure of the materials and porosity are assessed using infrared spectroscopy, swelling, and degradation experiments. The utility of this approach is examined with two different crosslinking strategies using glutaraldehyde or CaCl2. Multilayer cylindrical structures are successfully 3D printed, and their porous structure is confirmed by scanning electron microscopy and Brunauer-Emmett-Teller surface area analyses. Moreover, cytocompatibility of the hydrogel scaffolds is confirmed on fibroblast cells. The developed material is completely natural, biocompatible, economical, and the method is facile. Thus, this study is important for the development of advanced functional 3D hydrogels that have considerable potential for biomedical devices and artificial tissues.
  • Thumbnail Image
    PublicationOpen Access
    3D-printed microneedles in biomedical applications
    (Elsevier, 2021) Rahbarghazi, Reza; Yetişen, Ali Kemal; N/A; Department of Mechanical Engineering; Dabbagh, Sajjad Rahmani; Sarabi, Misagh Rezapour; Sokullu, Emel; Taşoğlu, Savaş; Faculty Member; Faculty Member; Department of Mechanical Engineering; KU Arçelik Research Center for Creative Industries (KUAR) / KU Arçelik Yaratıcı Endüstriler Uygulama ve Araştırma Merkezi (KUAR); Koç University Research Center for Translational Medicine (KUTTAM) / Koç Üniversitesi Translasyonel Tıp Araştırma Merkezi (KUTTAM); Graduate School of Social Sciences and Humanities; Graduate School of Sciences and Engineering; School of Medicine; College of Engineering; N/A; N/A; 163024; 291971
    Conventional needle technologies can be advanced with emerging nano- and micro-fabrication methods to fabricate microneedles. Nano-/micro-fabricated microneedles seek to mitigate penetration pain and tissue damage, as well as providing accurately controlled robust channels for administrating bioagents and collecting body fluids. Here, design and 3D printing strategies of microneedles are discussed with emerging applications in biomedical devices and healthcare technologies. 3D printing offers customization, cost-efficiency, a rapid turnaround time between design iterations, and enhanced accessibility. Increasing the printing resolution, the accuracy of the features, and the accessibility of low-cost raw printing materials have empowered 3D printing to be utilized for the fabrication of microneedle platforms. The development of 3D-printed microneedles has enabled the evolution of pain-free controlled release drug delivery systems, devices for extracting fluids from the cutaneous tissue, biosignal acquisition, and point-of-care diagnostic devices in personalized medicine.
  • Thumbnail Image
    PublicationOpen Access
    3D-printed microrobots from design to translation
    (Nature Portfolio, 2022) Department of Mechanical Engineering; N/A; Dabbagh, Sajjad Rahmani; Sarabi, Misagh Rezapour; Birtek, Mehmet Tuğrul; Sitti, Metin; Taşoğlu, Savaş; Faculty Member; Faculty Member; Department of Mechanical Engineering; KU Arçelik Research Center for Creative Industries (KUAR) / KU Arçelik Yaratıcı Endüstriler Uygulama ve Araştırma Merkezi (KUAR); Koç Üniversitesi İş Bankası Yapay Zeka Uygulama ve Araştırma Merkezi (KUIS AI)/ Koç University İş Bank Artificial Intelligence Center (KUIS AI); Koç University Research Center for Translational Medicine (KUTTAM) / Koç Üniversitesi Translasyonel Tıp Araştırma Merkezi (KUTTAM); Graduate School of Health Sciences; Graduate School of Sciences and Engineering; School of Medicine; College of Engineering; N/A; N/A; N/A; N/A; 297104; 291971
    Microrobots have attracted the attention of scientists owing to their unique features to accomplish tasks in hard-to-reach sites in the human body. Microrobots can be precisely actuated and maneuvered individually or in a swarm for cargo delivery, sampling, surgery, and imaging applications. In addition, microrobots have found applications in the environmental sector (e.g., water treatment). Besides, recent advancements of three-dimensional (3D) printers have enabled the high-resolution fabrication of microrobots with a faster design-production turnaround time for users with limited micromanufacturing skills. Here, the latest end applications of 3D printed microrobots are reviewed (ranging from environmental to biomedical applications) along with a brief discussion over the feasible actuation methods (e.g., on- and off-board), and practical 3D printing technologies for microrobot fabrication. In addition, as a future perspective, we discussed the potential advantages of integration of microrobots with smart materials, and conceivable benefits of implementation of artificial intelligence (AI), as well as physical intelligence (PI). Moreover, in order to facilitate bench-to-bedside translation of microrobots, current challenges impeding clinical translation of microrobots are elaborated, including entry obstacles (e.g., immune system attacks) and cumbersome standard test procedures to ensure biocompatibility.