Development of an Ex Vivo Mitral Valve Evaluation Model Using a Pulsatile Flow Simulator

Placeholder

Departments

School / College / Institute

Organizational Unit
Organizational Unit
SCHOOL OF MEDICINE
Upper Org Unit

Program

KU Authors

Co-Authors

Albrahimi, Ergida
Aka, Ibrahim Basar
Ali, Mhd Homam Alhaj
Korun, Oktay
Odemis, Ender
Ipek, Gokhan

Publication Date

Language

Embargo Status

No

Journal Title

Journal ISSN

Volume Title

Alternative Title

Abstract

Surgical mitral valve repair remains a challenging procedure. Although several repair techniques have been defined, data comparing their hemodynamic effects are lacking. The commercially available pulse duplicators are commonly used to simulate blood circulation through mechanical or 3D printed cardiac valves. However, due to the specific structure and working mechanism of the mitral valve, the experiments on surgical techniques require the use of biological tissues. Ex vivo lamb mitral valves are suitable for such experiments, but the methods for mounting these valves to the pulse duplicator system (PDS) are not well defined. To address this, we modified the system by 3D printing and silicone molding as a mitral valve holder. We excised the mitral valve from a lamb heart for each experiment, including its annulus and subvalvar apparatus. We implanted this into the atrioventricular (mitral) valve area of the test machine using the silicone holder. Papillary muscle tension was simulated by tying sutures around the chordae-papillary junctions and passing these sutures through the release hole at the bottom of the ventricular chamber. Initial testing of the valve competence was conducted at a heart rate of 120 beats per minute and a cardiac output of 2 L/min. Valve regurgitation and the pressure gradient between the atrial and ventricular chambers were measured using pulse duplicator electromagnetic flowmeters and validated with echocardiography. Baseline hemodynamic testing demonstrated consistent valve function across five experiments, with a mean regurgitation fraction of 21.1% and echo-derived transmitral gradients ranging from 5.15 to 8.13 mmHg. Stroke volumes and peak flow rates varied among specimens, reflecting physiological variability within the pediatric model.

Source

Publisher

Journal Of Visualized Experiments

Subject

Multidisciplinary Sciences

Citation

Has Part

Source

Jove-journal of visualized experiments

Book Series Title

Edition

DOI

10.3791/68173

item.page.datauri

Link

Rights

Copyrights Note

Endorsement

Review

Supplemented By

Referenced By

0

Views

0

Downloads

View PlumX Details