Abstract

Background: Resorbable mesh and porous polyethylene are frequently used alloplastic materials for the treatment of the orbital blowout fractures. The literature lacks reports comparing their long-term effects on experimental models. Objective: Our aim was to radiologically and histologically evaluate the effectiveness and safety of porous polyethylene and resorbable mesh in a rabbit orbital blowout fracture model. Methods: Twelve New Zealand white rabbits (24 orbits) were randomized to 4 groups. In group 1, only orbital floor dissection was done. In group 2, following orbital floor dissection, a 10-mm defect was created without any extra procedure. In group 3, following a 10-mm defect creation, a 12-mm-round cut porous polyethylene was placed on the defect. In group 4, following a 10-mm defect creation, a 12-mm-round cut resorbable mesh was placed on the defect. Computed tomographic analysis was performed during follow-up period. Orbital floors were evaluated histologically at month 6. Results: No clinical complications were observed during follow-up period. In radiological evaluation, there was no statistically significant difference between groups regarding bone formation. In histological evaluation, the connective tissue was denser, and organized and better bone formation was observed in group 3 and 4 when compared with other groups. Conclusion: Although no significant radiological changes were present, porous polyethylene and resorbable mesh performed better histologically. They were effective and well tolerated for reconstruction of the isolated orbital floor defects.

Source

Publisher

Sage

Citation

item.page.haspartof

Source

Plastic Surgery

item.page.ispartofseries

item.page.edition

DOI

10.1177/2292550317702370

item.page.datauri

item.page.link

Rights

N/A

Copyrights Note

Rights and licensing

N/A

Endorsement

Review

Supplemented By

Referenced By

Related Patent

Related Goal

Google Scholar
Scholar'da Ara ↗
2
Görüntülenme
0
İndirme
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators