Comparison of resorbable mesh (Poly L-lactide/Glycolic acid) and porous polyethylene in orbital floor fractures in an experimental model

Placeholder

Departments

School / College / Institute

Organizational Unit
Organizational Unit
SCHOOL OF MEDICINE
Upper Org Unit

Program

KU Authors

Co-Authors

Aral, Ali Mubin
Kaya, Basar
Coskun, Neslihan
Omeroglu, Suna
Kilic, Koray

Publication Date

Language

Embargo Status

Journal Title

Journal ISSN

Volume Title

Alternative Title

Comparaison entre le treillis résorbable (Poly L-lactide et polyacide glycolique) et le polyéthylène poreux en cas de fracture du plancher orbital dans un modèle expérimental

Abstract

Background: Resorbable mesh and porous polyethylene are frequently used alloplastic materials for the treatment of the orbital blowout fractures. The literature lacks reports comparing their long-term effects on experimental models. Objective: Our aim was to radiologically and histologically evaluate the effectiveness and safety of porous polyethylene and resorbable mesh in a rabbit orbital blowout fracture model. Methods: Twelve New Zealand white rabbits (24 orbits) were randomized to 4 groups. In group 1, only orbital floor dissection was done. In group 2, following orbital floor dissection, a 10-mm defect was created without any extra procedure. In group 3, following a 10-mm defect creation, a 12-mm-round cut porous polyethylene was placed on the defect. In group 4, following a 10-mm defect creation, a 12-mm-round cut resorbable mesh was placed on the defect. Computed tomographic analysis was performed during follow-up period. Orbital floors were evaluated histologically at month 6. Results: No clinical complications were observed during follow-up period. In radiological evaluation, there was no statistically significant difference between groups regarding bone formation. In histological evaluation, the connective tissue was denser, and organized and better bone formation was observed in group 3 and 4 when compared with other groups. Conclusion: Although no significant radiological changes were present, porous polyethylene and resorbable mesh performed better histologically. They were effective and well tolerated for reconstruction of the isolated orbital floor defects.

Source

Publisher

Sage

Subject

Surgery

Citation

Has Part

Source

Plastic Surgery

Book Series Title

Edition

DOI

10.1177/2292550317702370

item.page.datauri

Link

Rights

Copyrights Note

Endorsement

Review

Supplemented By

Referenced By

0

Views

0

Downloads

View PlumX Details