Publication:
A wearable touch-activated device integrated with hollow microneedles for continuous sampling and sensing of dermal interstitial fluid

Placeholder

Program

School / College / Institute

College of Engineering
GRADUATE SCHOOL OF SCIENCES AND ENGINEERING
Research Center

KU Authors

Co-Authors

Istif, Emin

Publication Date

Language

Embargo Status

Journal Title

Journal ISSN

Volume Title

Alternative Title

Abstract

Dermal interstitial fluid (ISF) is emerging as a rich source of biomarkers that complements conventional biofluids such as blood and urine. However, the impact of ISF sampling in clinical applications has been limited owing to the challenges associated with extraction. The implementation of microneedle-based wearable devices that can extract dermal ISF in a pain-free and easy-to-use manner has attracted growing attention in recent years. Here, a fully integrated touch-activated wearable device based on a laser-drilled hollow microneedle (HMN) patch for continuous sampling and sensing of dermal ISF is introduced. The developed platform can produce and maintain the required vacuum pressure (as low as approximate to -53 kPa) to collect adequate volumes of ISF (approximate to 2 mu L needle-1 h-1) for medical applications. The vacuum system can be activated through a one-touch finger operation. A parametric study is performed to investigate the effect of microneedle array size, vacuum pressure, and extraction duration on collected ISF. The capability of the proposed platform for continuous health monitoring is further demonstrated by the electrochemical detection of glucose and pH levels of ISF in animal models. This HMN-based system provides an alternative tool to the existing invasive techniques for ISF collection and sensing for medical diagnosis and treatment. A fully-integrated touch-activated wearable device is developed for continuous sampling and electrochemical analysis of interstitial fluid. The elastic self-recovery of the vacuum generation system enables a wide range of negative pressures and extraction rates. The developed device can successfully detect glucose and pH levels and holds the potential for continuous sensing of multiple biomarkers in extracted interstitial fluid.image

Source

Publisher

Wiley-V C H Verlag Gmbh

Subject

Chemistry, multidisciplinary, Chemistry, physical, Nanoscience and nanotechnology, Materials science, multidisciplinary, Physics, applied, Physics, condensed matter

Citation

Has Part

Source

Advanced Materials

Book Series Title

Edition

DOI

10.1002/adma.202470012

item.page.datauri

Link

Rights

Rights URL (CC Link)

Copyrights Note

Endorsement

Review

Supplemented By

Referenced By

5

Views

0

Downloads

View PlumX Details